Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations

被引:3
|
作者
Hadad, Kamal [1 ]
Saeedi-Moghadam, Mahdi [2 ]
Zeinali-Rafsanjani, Banafsheh [2 ,3 ]
机构
[1] Shiraz Univ, Sch Mech Engn, Dept Nucl Engn, Shiraz, Iran
[2] Shiraz Univ Med Sci, Med Imaging Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Nucl Med & Mol Imaging Res Ctr, Shiraz, Iran
关键词
MCNPX; EGSnrc; voxel phantom; patient specific phantom; DOSXYZnrc; DVH; HYBRID COMPUTATIONAL PHANTOMS; CANCER-RISK ESTIMATION; RADIATION-THERAPY; DOSE CALCULATION; HUMAN ANATOMY; VALIDATION; EGS4; ELECTRON; MODELS; TOOL;
D O I
10.3233/THC-161240
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
INTRODUCTION: Dose evaluation with two Monte Carlo codes using patient specific voxel phantom is presented in this paper. We employ both MCNPX and DOSXYZnrc to perform dosimetry for mathematical voxel phantoms generated by our in-house developed voxel phantom generator and EGSnrc/CTCreate respectively. MATERIAL AND METHOD: Our case study was a 2.5 x 2.4 x 2.4 cm(3) tumor in the middle lobe of right lung of a male patient exposed to 6MV parallel beam. In order to compare these Monte Carlo codes with together gross tumor volume (GTV) and organ at risks (OAR) doses and dose volume histograms (DVH) were calculated. RESULTS: Comparing the mean absorbed dose results (in Gy) from both codes indicates that gross tumor volume, heart and spinal cord have 2% to 10% difference. The 10% difference between the codes were from the spinal cord region where was not in the therapy beam and it just received the scatter radiation. The dose volume DVH obtained from DOSXYZnrc results demonstrate a milder slope compared with MCNPX DVHs. CONCLUSION: It was revealed that MCNPX has some advantages in comparison to DOSXYZnrc, but it is important to consider that for equal precision in voxel dosimetry calculation, DOSXYZnrc runs faster than MCNPX and it is a great advantage.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [31] Patient specific dosimetry based on quantitative SPECT imaging and 3D-DFT convolution: A comparison with Monte Carlo transport calculations.
    Akabani, G
    Hawkins, WG
    Eckblade, MB
    Leichner, PK
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 347 - 347
  • [32] Comparison of I-131 Radioimmunotherapy Tumor Dosimetry: Unit Density Sphere Model Versus Patient-Specific Monte Carlo Calculations
    Howard, David M.
    Kearfott, Kimberlee J.
    Wilderman, Scott J.
    Dewaraja, Yuni K.
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2011, 26 (05) : 615 - 621
  • [33] Comparison of Voxel S-values and Monte Carlo Simulation in [177Lu]Lu-DOTA-TATE Quantification for Patient-Specific Dosimetry
    Rodrigues, C.
    Ferreira, P.
    Oliveira, F. P. M.
    Silva, A.
    Peralta, L.
    Costa, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S75 - S75
  • [34] COMPARISONS OF THE CALCULATIONS USING DIFFERENT CODES IMPLEMENTED IN MCNPX MONTE CARLO TRANSPORT CODE FOR ACCELERATOR DRIVEN SYSTEM TARGET
    Sarer, Basar
    Sahin, Sumer
    Gunay, Mehtap
    Celik, Yurdunaz
    FUSION SCIENCE AND TECHNOLOGY, 2012, 61 (1T) : 302 - 307
  • [35] ATOM-MIRD Hybrid Voxel Model for Monte Carlo Calculations of Organ Doses: A Complement to a Physical Phantom
    Cho, Sungkoo
    Choi, Sang Hyoun
    Yi, Chul-Young
    Kim, Chan Hyeong
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 306 - 308
  • [36] The Impact of Tissue Type and Density on Dose Point Kernels for Patient-Specific Voxel-Wise Dosimetry: A Monte Carlo Investigation
    Tiwari, Ashok
    Graves, Stephen A.
    Sunderland, John
    RADIATION RESEARCH, 2020, 193 (06) : 531 - 542
  • [37] Monte Carlo Simulations of Photon Absorbed Fractions in a Frog Voxel Phantom
    Kinase, Sakae
    PROCEEDINGS OF THE IEEE, 2009, 97 (12) : 2086 - 2097
  • [38] A fast voxel-based Monte Carlo method for scanner- and patient-specific dose calculations in computed tomography
    Schmidt, B
    Kalender, WA
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2002, 18 (02): : 43 - 53
  • [39] Optimized Monte Carlo simulations for voxel-based internal dosimetry
    Cordeiro, Leanderson P.
    de Sa, Lidia, V
    Kitamikado, Rafael A.
    Sapienza, Marcelo T.
    Bonifacio, Daniel A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [40] Monte Carlo modelling for in vivo measurements of americium in a knee voxel phantom:: General criteria for an international comparison
    Gomez-Ros, J. M.
    de Carlan, L.
    Franck, D.
    Gualdrini, G.
    Lis, M.
    Lopez, M. A.
    Moraleda, M.
    Zankl, M.
    RADIATION PROTECTION DOSIMETRY, 2007, 127 (1-4) : 245 - 248