Interference of Electronic Apex Locators with Implantable Cardioverter Defibrillators

被引:15
|
作者
Idzahi, Karim [1 ,4 ]
de Cock, Carel C. [5 ,6 ]
Shemesh, Hagay [1 ]
Brand, Henk S. [2 ,3 ,4 ]
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Endodontol, NL-1081 BT Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Oral Biochem, NL-1081 BT Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Oral Maxillofacial Surg, NL-1081 BT Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, NL-1081 LA Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Dept Cardiol, Med Ctr, NL-1081 LA Amsterdam, Netherlands
[6] Vrije Univ Amsterdam, Inst Cardiovasc Res VU, Med Ctr, NL-1081 LA Amsterdam, Netherlands
关键词
Electromagnetic interference; electronic apex locator; implantable cardioverter defibrillator; CARDIAC-PACEMAKER; DENTAL DEVICES; PULP TESTERS; PART II; ENVIRONMENT; PATIENT;
D O I
10.1016/j.joen.2013.07.027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this in vitro study was to evaluate the potential electromagnetic interference of electronic apex locators (EALs) on implantable cardioverter defibrillators (ICDs). Methods: Four different EALs were tested for their ability to interfere with the correct function of 3 different ICDs. Each ICD was placed in a plastic container with 1.5 L physiological saline, and the EAL unit was placed at a distance of 2.5 cm from the ICD. The file electrode and lip clip were placed directly against the ICD. The EAL was turned on for 30 seconds while continuously showing the "APEX" mark. As a negative control, the ICD was tested without EAL for 30 seconds. An electrosurgical unit served as a positive control. During each test, the ICD output was monitored continuously by real-time telemetry, and after completion of the experiment, intracardiac electrocardiograms were printed. The tests were repeated 3 times for each device. The electrocardiograms were examined for interference on ICD ventricular activity. Results: All EALs tested and the negative control failed to produce electromagnetic interference in each of the ICDs tested. The electrosurgical unit induced interference in the ICDs, which were detected as episodes of ventricular tachycardia and led to the initiation of electrical shocks in all ICDs. Conclusions: The 4 EALs tested did not interfere with the correct functioning of ICDs in vitro.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [41] Low risk of electromagnetic interference between smartphones and contemporary implantable cardioverter defibrillators
    Burri, Haran
    Engkolo, Louis Paulin Mondouagne
    Dayal, Nicolas
    Etemadi, Abdul
    Makhlouf, Anne-Marie
    Stettler, Carine
    Trentaz, Florence
    EUROPACE, 2016, 18 (05): : 726 - 731
  • [42] In vitro tests of electromagnetic interference of electromagnetic navigational bronchoscopy to implantable cardioverter defibrillators
    Magnani, Andrea
    Matheoud, Roberta
    Brambilla, Marco
    Valzano, Serena
    Occhetta, Eraldo
    Marino, Paolo
    Balbo, Piero
    EUROPACE, 2012, 14 (07): : 1054 - 1059
  • [43] Induction ovens and electromagnetic interference: What is the risk for patients with implantable cardioverter defibrillators?
    Binggeli, C
    Rickli, H
    Ammann, P
    Brunckhorst, C
    Hufschmid, U
    Luechinger, R
    Duru, F
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (04) : 399 - 401
  • [44] Electromagnetic Interference With Implantable Cardioverter-Defibrillators at Power Frequency An In Vivo Study
    Napp, Andreas
    Joosten, Stephan
    Stunder, Dominik
    Knackstedt, Christian
    Zink, Matthias
    Bellmann, Barbara
    Marx, Nikolaus
    Schauerte, Patrick
    Silny, Jiri
    CIRCULATION, 2014, 129 (04) : 441 - 450
  • [45] Radiography of Pacemakers and Implantable Cardioverter Defibrillators
    Costelloe, Colleen M.
    Murphy, William A., Jr.
    Gladish, Gregory W.
    Rozner, Marc A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1252 - 1258
  • [46] Implantable Cardioverter Defibrillators for Nonischemic Cardiomyopathy
    Shah, Rahman
    Sabghi, Roxanna
    Dennis, Mary
    JAMA CARDIOLOGY, 2017, 2 (11) : 1282 - 1283
  • [47] Detection algorithms in implantable cardioverter defibrillators
    Univ of Michigan, Ann Arbor, United States
    Proc IEEE, 3 (428-445):
  • [48] Implantable cardioverter defibrillators in Asian population
    Lau, Chu-Pak
    Hai, Jo-Jo
    Siu, Chung-Wah
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (12): : 1627 - 1629
  • [49] Use of implantable cardioverter-defibrillators
    Aronow, Wilbert S.
    FUTURE CARDIOLOGY, 2010, 6 (06) : 859 - 870
  • [50] PTSD and automatic implantable cardioverter defibrillators
    Hamner, M
    Hunt, N
    Gee, J
    Garrell, R
    Monroe, R
    PSYCHOSOMATICS, 1999, 40 (01) : 82 - 85