Interference of Electronic Apex Locators with Implantable Cardioverter Defibrillators

被引:15
|
作者
Idzahi, Karim [1 ,4 ]
de Cock, Carel C. [5 ,6 ]
Shemesh, Hagay [1 ]
Brand, Henk S. [2 ,3 ,4 ]
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Endodontol, NL-1081 BT Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Oral Biochem, NL-1081 BT Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Oral Maxillofacial Surg, NL-1081 BT Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, NL-1081 LA Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Dept Cardiol, Med Ctr, NL-1081 LA Amsterdam, Netherlands
[6] Vrije Univ Amsterdam, Inst Cardiovasc Res VU, Med Ctr, NL-1081 LA Amsterdam, Netherlands
关键词
Electromagnetic interference; electronic apex locator; implantable cardioverter defibrillator; CARDIAC-PACEMAKER; DENTAL DEVICES; PULP TESTERS; PART II; ENVIRONMENT; PATIENT;
D O I
10.1016/j.joen.2013.07.027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this in vitro study was to evaluate the potential electromagnetic interference of electronic apex locators (EALs) on implantable cardioverter defibrillators (ICDs). Methods: Four different EALs were tested for their ability to interfere with the correct function of 3 different ICDs. Each ICD was placed in a plastic container with 1.5 L physiological saline, and the EAL unit was placed at a distance of 2.5 cm from the ICD. The file electrode and lip clip were placed directly against the ICD. The EAL was turned on for 30 seconds while continuously showing the "APEX" mark. As a negative control, the ICD was tested without EAL for 30 seconds. An electrosurgical unit served as a positive control. During each test, the ICD output was monitored continuously by real-time telemetry, and after completion of the experiment, intracardiac electrocardiograms were printed. The tests were repeated 3 times for each device. The electrocardiograms were examined for interference on ICD ventricular activity. Results: All EALs tested and the negative control failed to produce electromagnetic interference in each of the ICDs tested. The electrosurgical unit induced interference in the ICDs, which were detected as episodes of ventricular tachycardia and led to the initiation of electrical shocks in all ICDs. Conclusions: The 4 EALs tested did not interfere with the correct functioning of ICDs in vitro.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [21] Interference between pacemakers/implantable cardioverter defibrillators and video capsule endoscopy
    Bandorski, Dirk
    Gehron, Johannes
    Hoeltgen, Reinhard
    WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2013, 5 (04): : 201 - 202
  • [22] Deactivating implantable cardioverter defibrillators
    Lynn, J
    ANNALS OF INTERNAL MEDICINE, 2005, 143 (09) : 691 - 691
  • [23] IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    KUTALEK, SP
    DREIFUS, LS
    ADVANCES IN INTERNAL MEDICINE, VOLUME 38, 1993, 38 : 421 - 438
  • [24] Athletes with Implantable Cardioverter Defibrillators
    Ponamgi, Shiva P.
    DeSimone, Christopher V.
    Ackerman, Michael J.
    CLINICS IN SPORTS MEDICINE, 2015, 34 (03) : 473 - +
  • [25] Deactivation of implantable cardioverter defibrillators
    Wan, Darryl
    Chakrabarti, Santabhanu
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (33) : E1326 - E1327
  • [26] Advances in implantable cardioverter defibrillators
    Swygman, C
    Wang, PJ
    Link, MS
    Homoud, MK
    Estes, NAM
    CURRENT OPINION IN CARDIOLOGY, 2002, 17 (01) : 24 - 28
  • [27] Implantable cardioverter-defibrillators
    Pinski, SL
    Fahy, GJ
    AMERICAN JOURNAL OF MEDICINE, 1999, 106 (04): : 446 - 458
  • [28] Implantable cardioverter-defibrillators
    Zaidan, JR
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (04) : 475 - 483
  • [29] Implantable cardioverter-defibrillators
    Connelly, DT
    HEART, 2001, 86 (02) : 221 - 226
  • [30] Pacemakers and implantable cardioverter defibrillators
    Allen, M.
    ANAESTHESIA, 2006, 61 (09) : 883 - 890