Review of the Mechanical Behavior of Different Implant-Abutment Connections

被引:54
|
作者
Vinhas, Ana Sofia [1 ]
Aroso, Carlos [2 ]
Salazar, Filomena [1 ]
Lopez-Jarana, Paula [1 ]
Rios-Santos, Jose Vicente [3 ]
Herrero-Climent, Mariano [4 ]
机构
[1] Inst Univ Ciencias Saude, Dept Periodontol, P-4585116 Gandra, Portugal
[2] Inst Univ Ciencias Saude, Dept Prosthodont, P-4585116 Gandra, Portugal
[3] Univ Seville, Sch Dent, Dept Periodontol, C Avicena S-N, Seville 41009, Spain
[4] Porto Dent Inst, P-4150518 Porto, Portugal
关键词
implant– abutment connection; preload; tightening torque; cyclic loading; misfit; microleakage; IN-VITRO EVALUATION; EXTERNAL-CONNECTION; TORQUE MAINTENANCE; BACTERIAL LEAKAGE; REMOVAL TORQUE; PRELOAD; HEXAGON; DESIGN; INTERFACE; FATIGUE;
D O I
10.3390/ijerph17228685
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction: Different implant-abutment connections have been developed to reduce mechanical and biological failure. The most frequent complications are loss of preload, screw loosening, abutment or implant fracture, deformations at the different interfaces, and bacterial microleakage. Aim: To review the evidence indicating whether the implant-abutment connection type is significant regarding the following issues: (1) maintenance of the preload in static and dynamic in vitro studies; (2) assessment of possible deformations at the implant-abutment interfaces, after repeated application of the tightening torque; (3) evaluation of the sealing capability of different implant connections against microleakage. Materials and Methods: In June 2020, an electronic literature search was performed in Medline, EBSCO host, and PubMed databases. The search was focused on the ability of different implant connections to maintain preload, resist deformation after tightening and retightening, and prevent microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full-text reading. Results: The literature search conducted for this review initially resulted in 68 articles, among which 19 articles and 1 systematic review fulfilled the criteria for inclusion. The studies were divided according to the three proposed objectives, with some studies falling into more than one category (maintenance of preload, surface abutment-implant deformation, and resistance to microleakage). Conclusions: Conical abutment appears to result in fewer mechanical complications, such as screw loosening or fractures, and higher torque preservation. After SEM evaluation, damage was observed in the threads of the abutment screws, before and after loading in internal and external connections. Internal hexagon implants and predominantly internal conical (Morse taper) implants showed less microleakage in dynamic loading conditions. We suggest further studies to guarantee excellence in methodological quality.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 50 条
  • [21] Analysis of the Mechanical Behavior and Effect of Cyclic Fatigue on the Implant-Abutment Interface
    German Sandoval, Ramon
    Ortiz Magdaleno, Marine
    Sanchez Robles, Paula
    Zavala Alonso, Norma
    Romo Ramirez, Gabriel Fernando
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (02) : 104 - 114
  • [22] Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections
    Ugurel, Cihan Sadi
    Steiner, Martin
    Isik-Ozkol, Gul
    Kutay, Omer
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 137 - 142
  • [23] The Influence of Torque Tightening on the Position Stability of the Abutment in Conical Implant-Abutment Connections
    Hogg, Wiebke Semper
    Zulauf, Kris
    Mehrhof, Juergen
    Nelson, Katja
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (05) : 538 - 541
  • [24] Effects of different implant-abutment connections on micromotion and stress distribution: Prediction of microgap formation
    Saidin, Syafiqah
    Kadir, Mohammed Rafiq Abdul
    Sulaiman, Eshamsul
    Abu Kasim, Noor Hayaty
    JOURNAL OF DENTISTRY, 2012, 40 (06) : 467 - 474
  • [25] Molecular leakage at implant-abutment connection—in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration
    Sönke Harder
    Birka Dimaczek
    Yaha Açil
    Hendrik Terheyden
    Sandra Freitag-Wolf
    Matthias Kern
    Clinical Oral Investigations, 2010, 14 : 427 - 432
  • [26] Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants
    Gil, F. J.
    Herrero-Climent, M.
    Lazaro, P.
    Rios, J. V.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (07) : 1825 - 1830
  • [27] A Retrospective Study of Implant-Abutment Connections on Crestal Bone Level
    Lin, M. -I.
    Shen, Y. -W.
    Huang, H. -L.
    Hsu, J. -T.
    Fuh, L. -J.
    JOURNAL OF DENTAL RESEARCH, 2013, 92 (S12) : 202S - 207S
  • [28] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [29] Evaluation of the Mechanical Reliability of Different Implant-Abutment Connections for Single Crowns According to the ISO 14801 Fatigue Test Protocol
    Thome, Geninho
    Torres Gomes, Andre Felipe
    de Moura, Marcos Boaventura
    Beng, Christian Felippi
    Trojan, Larissa Carvalho
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (01) : 47 - 54
  • [30] The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study
    Bagegni, Aimen
    Weihrauch, Vincent
    Vach, Kirstin
    Kohal, Ralf
    MATERIALS, 2022, 15 (09)