3D Dose Reconstruction using EPID Images Acquired during IMRT Treatment

被引:0
|
作者
Zhao, B. [1 ]
Yang, Y. [1 ]
Li, T. [1 ]
Heron, D. E. [1 ]
Huq, M. S. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Pittsburgh, PA USA
关键词
D O I
10.1016/j.ijrobp.2009.07.1448
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S633 / S634
页数:2
相关论文
共 50 条
  • [31] Multimodal 3D Facade Reconstruction Using 3D LiDAR and Images
    Xu, Haotian
    Chen, Chia-Yen
    Delmas, Patrice Jean
    Gee, Trevor Edwin
    van der Mark, Wannes
    [J]. IMAGE AND VIDEO TECHNOLOGY (PSIVT 2019), 2019, 11854 : 281 - 295
  • [32] A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments
    Wendling, Markus
    McDermott, Leah N.
    Mans, Anton
    Sonke, Jan-Jakob
    van Herk, Marcel
    Mijnheer, Ben J.
    [J]. MEDICAL PHYSICS, 2009, 36 (07) : 3310 - 3321
  • [33] Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT
    Visser, R.
    Godart, J.
    Wauben, D. J. L.
    Langendijk, J. A.
    van't Veld, A. A.
    Korevaar, E. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (23): : N642 - N649
  • [34] An investigation of gantry angle data accuracy for cine-mode EPID images acquired during arc IMRT
    McCowan, Peter M.
    Rickey, Daniel W.
    Rowshanfarzad, Pejman
    Greer, Peter B.
    Ansbacher, William
    McCurdy, Boyd M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 187 - 201
  • [35] An Efficient Method of 3D Patient Dose Reconstruction Based On EPID Measurements for Pre-Treatment Patient Specific QA
    David, R.
    Zwan, B.
    Hindmarsh, J.
    Seymour, E.
    Kandasamy, K.
    Arthur, G.
    Lee, C.
    Greer, P.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3718 - 3718
  • [36] Quality Assurace for Large Field IMRT Using EPID Images
    Rice, R.
    Kim, G.
    Kinsey, E.
    Whitaker, M.
    Pawlicki, T.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [37] Clinical Implementation of a Comprehensive EPID-Based 3D/4D Patient Dose Reconstruction Framework for Complex Treatment Validations
    Lin, M.
    Jinsheng, L.
    Ma, C. M. Charlie
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S151 - S152
  • [38] 3D building facade model reconstruction using parallel images acquired by line scan cameras
    Kataoka, K
    Osawa, T
    Ozawa, S
    Wakabayashi, K
    Arakawa, K
    [J]. 2005 International Conference on Image Processing (ICIP), Vols 1-5, 2005, : 213 - 216
  • [39] Investigations of an EPID Based 3D Dose Reconstruction Method for Applications in MRI-Linac Radiotherapy
    McNeilly, Adam
    Greer, Peter
    Fuangrod, Todsaporn
    Van Beek, Timothy
    Van Uytven, Eric
    Chytyk-Praznik, Krista
    Zwan, Benjamin
    [J]. ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2018, 14 : 30 - 31
  • [40] Dose Verification for IMRT DMLC Delivery Using An EPID Imager
    Zhao, B.
    Yang, Y.
    Li, T.
    Li, X.
    Heron, D.
    Huq, M.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)