Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT

被引:1
|
作者
Visser, R. [1 ,2 ]
Godart, J. [1 ]
Wauben, D. J. L. [1 ]
Langendijk, J. A. [1 ]
van't Veld, A. A. [1 ]
Korevaar, E. W. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
[2] Hanze Univ Appl Sci, Res Grp Hlth Ageing Allied Hlth Care & Nursing, Groningen, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 23期
关键词
MLC; iterative reconstruction; 3D dose reconstruction; high resolution; 2D detector array; QUALITY-ASSURANCE; DOSIMETRY; VERIFICATION; FILM; BEAM; STEP;
D O I
10.1088/0031-9155/61/23/N642
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In pre-treatment dose verification, low resolution detector systems are unable to identify shifts of individual leafs of high resolution multi leaf collimator (MLC) systems from detected changes in the dose deposition. The goal of this study was to introduce an alternative approach (the shutter technique) combined with a previous described iterative reconstruction method to accurately reconstruct high resolution MLC leaf positions based on low resolution measurements. For the shutter technique, two additional radiotherapy treatment plans (RT-plans) were generated in addition to the original RT-plan; one with even MLC leafs closed for reconstructing uneven leaf positions and one with uneven MLC leafs closed for reconstructing even leaf positions. Reconstructed leaf positions were then implemented in the original RT-plan for 3D dose reconstruction. The shutter technique was evaluated for a 6 MV Elekta SLi linac with 5 mm MLC leafs (Agility (TM)) in combination with the MatriXX Evolution detector with detector spacing of 7.62mm. Dose reconstruction was performed with the COMPASS system (v2.0). The measurement setup allowed one row of ionization chambers to be affected by two adjacent leaf pairs. Measurements were obtained for various field sizes with MLC leaf position errors ranging from 1.0mm to 10.0mm. Furthermore, one clinical head and neck IMRT treatment beam with MLC introduced leaf position errors of 5.0mm was evaluated to illustrate the impact of the shutter technique on 3D dose reconstruction. Without the shutter technique, MLC leaf position reconstruction showed reconstruction errors up to 6.0mm. Introduction of the shutter technique allowed MLC leaf position reconstruction for the majority of leafs with sub-millimeter accuracy resulting in a reduction of dose reconstruction errors. The shutter technique in combination with the iterative reconstruction method allows high resolution MLC leaf position reconstruction using low resolution measurements with sub-millimeter accuracy.
引用
收藏
页码:N642 / N649
页数:8
相关论文
共 50 条
  • [1] Development of an iterative reconstruction method to overcome 2D detector low resolution limitations in MLC leaf position error detection for 3D dose verification in IMRT
    Visser, R.
    Godart, J.
    Wauben, D. J. L.
    Langendijk, J. A.
    van't Veld, A. A.
    Korevaar, E. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (10): : 3843 - 3856
  • [2] RECONSTRUCTION OF HIGH RESOLUTION 3D DOSE FROM LOW RESOLUTION MATRIX MEASUREMENTS: A CORRECTION KERNEL METHOD
    Godart, J.
    Korevaar, E.
    Visser, R.
    Wauben, D.
    van 't Veld, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S171 - S171
  • [3] High resolution reconstruction for 3D SPECT
    Li, TF
    Wen, JH
    Lu, HB
    Li, X
    Liang, ZR
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1894 - 1900
  • [4] 3D cardiac anatomy reconstruction using high resolution CT data
    Chen, T
    Metaxas, D
    Axel, L
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 411 - 418
  • [5] A 3D vision system for high resolution surface reconstruction
    Marani, Roberto
    Roselli, Giuseppe
    Nitti, Massimiliano
    Cicirelli, Grazia
    D'Orazio, Tiziana
    Stella, Ettore
    [J]. 2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 157 - 162
  • [6] 3D Stereo Reconstruction: High Resolution Satellite Video
    Chernetskiy, M.
    Tao, Y.
    Muller, J-P
    [J]. IMAGE AND SIGNAL PROCESSING FOR REMOTE SENSING XXV, 2019, 11155
  • [7] Local Readjustment for High-Resolution 3D Reconstruction
    Zhu, Siyu
    Fang, Tian
    Xiao, Jianxiong
    Quan, Long
    [J]. 2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 3938 - 3945
  • [8] High resolution 3d reconstruction of the human gastroesophageal junction
    Yassi, Rita
    Cheng, Leo K.
    Gerneke, Dane
    Legrice, Ian
    Sands, Greg B.
    Windsor, John A.
    Pullan, Andrew J.
    [J]. GASTROENTEROLOGY, 2007, 132 (04) : A171 - A171
  • [9] A Method of 3D Dose Reconstruction Using MapCHECK Measurement for IMRT QA
    Kim, S.
    Barnett, E.
    Gallamore, M.
    Yeung, I.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [10] USING THE BUILT-IN DETECTOR FOR 3D DOSE RECONSTRUCTION IN TOMOTHERAPY
    Schombourg, K.
    Bochud, F.
    Mirimanoff, R. O.
    Moeckli, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S25 - S25