An investigation of gantry angle data accuracy for cine-mode EPID images acquired during arc IMRT

被引:19
|
作者
McCowan, Peter M. [1 ,2 ]
Rickey, Daniel W. [1 ,2 ,3 ]
Rowshanfarzad, Pejman [4 ]
Greer, Peter B. [4 ,5 ]
Ansbacher, William [6 ,7 ]
McCurdy, Boyd M. [1 ,2 ,3 ]
机构
[1] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB, Canada
[2] CancerCare Manitoba, Med Phys, Winnipeg, MB R3E 0V9, Canada
[3] Univ Manitoba, Dept Radiol, Winnipeg, MB, Canada
[4] Univ Western Australia, Sch Phys, Crawley, WA, Australia
[5] Calvary Mater Newcastle Hosp, Dept Radiat Oncol, Newcastle, NSW, Australia
[6] British Columbia Canc Agcy, Dept Med Phys, Victoria, BC, Canada
[7] Univ Victoria, Dept Phys & Astron, Victoria, BC, Canada
来源
关键词
gantry angle; linac; EPID; experimental; measurement; VOLUMETRIC-MODULATED ARC; DOSIMETRIC PROPERTIES; ACQUISITION MODE; VERIFICATION; RADIOTHERAPY; THERAPY; QA;
D O I
10.1120/jacmp.v15i1.4507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
EPID images acquired in cine mode during arc therapy have inaccurate gantry angles recorded in their image headers. In this work, methods were developed to assess the accuracy of the gantry potentiometer for linear accelerators. As well, assessments of the accuracy of other, more accessible, sources of gantry angle information ( i.e., treatment log files, analysis of EPID image headers) were investigated. The methods used in this study are generally applicable to any linear accelerator unit, and have been demonstrated here with Clinac/Trilogy systems. Gantry angle data were simultaneously acquired using three methods: i) a direct gantry potentiometer measurement, ii) an incremental rotary encoder, and iii) a custom-made radiographic gantry-angle phantom which produced unique wire intersections as a function of gantry angle. All methods were compared to gantry angle data from the EPID image header and the linac MLC DynaLog file. The encoder and gantry-angle phantom were used to validate the accuracy of the linac's potentiometer. The EPID image header gantry angles and the DynaLog file gantry angles were compared to the potentiometer. The encoder and gantry-angle phantom mean angle differences with the potentiometer were 0.13 degrees +/- 0.14 degrees and 0.10 degrees +/- 0.30 degrees, respectively. The EPID image header angles analyzed in this study were within +/- 1 degrees of the potentiometer angles only 35% of the time. In some cases, EPID image header gantry angles disagreed by as much as 3 degrees with the potentiometer. A time delay in frame acquisition was determined using the continuous acquisition mode of the EPID. After correcting for this time delay, 75% of the header angles, on average, were within +/- 1 degrees of the true gantry angle, compared to an average of only 35% without the correction. Applying a boxcar smoothing filter to the corrected gantry angles further improved the accuracy of the header-derived gantry angles to within +/- 1 degrees for almost all images ( 99.4%). An angle accuracy of 0.11 degrees +/- 0.04 degrees was determined using a point-by-point comparison of the gantry angle data in the MLC DynaLog file and the potentiometer data. These simple correction methods can be easily applied to individual treatment EPID images in order to more accurately define the gantry angle.
引用
收藏
页码:187 / 201
页数:15
相关论文
共 9 条
  • [1] Precise Gantry Angle Determination for EPID Images during Rotational IMRT
    McCowan, P.
    Rickey, D.
    Rowshanfarzad, P.
    Ansbacher, W.
    Greer, P.
    McCurdy, B.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3534 - +
  • [2] Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging
    Rowshanfarzad, Pejman
    Sabet, Mahsheed
    O'Connor, Daryl J.
    McCowan, Peter M.
    McCurdy, Boyd M. C.
    Greer, Peter B.
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 623 - 635
  • [3] Enhancing heart contrast in cine EPID images acquired during DIBH Breast Hybrid IMRT treatments
    Redekopp, Jonathan
    Aviles, Jorge Alpuche
    [J]. MEDICAL PHYSICS, 2024, 51 (08) : 5824 - 5824
  • [4] Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers
    Rowshanfarzad, Pejman
    Sabet, Mahsheed
    O'Connor, Daryl J.
    McCowan, Peter M.
    McCurdy, Boyd M. C.
    Greer, Peter B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 203 - 214
  • [5] Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries
    McCowan, P. M.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2016, 43 (01) : 254 - 261
  • [6] An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments
    Pejman Rowshanfarzad
    Conor K McGarry
    Michael P Barnes
    Mahsheed Sabet
    Martin A Ebert
    [J]. Radiation Oncology, 9
  • [7] An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments
    Rowshanfarzad, Pejman
    McGarry, Conor K.
    Barnes, Michael P.
    Sabet, Mahsheed
    Ebert, Martin A.
    [J]. RADIATION ONCOLOGY, 2014, 9
  • [8] 3D Dose Reconstruction using EPID Images Acquired during IMRT Treatment
    Zhao, B.
    Yang, Y.
    Li, T.
    Heron, D. E.
    Huq, M. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S633 - S634
  • [9] 3D Dose reconstruction: Banding artefacts in cine mode EPID images during VMAT delivery
    Woodruff, H. C.
    Greer, P. B.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444