Results with all-inside meniscal suture in pediatrics

被引:28
|
作者
Sehmitt, A. [1 ,2 ,3 ]
Batisse, F. [4 ]
Bonnard, C. [2 ,3 ]
机构
[1] CHU Tours, Serv Chirurg Orthoped & Traumatol, Ave Republ, F-37000 Tours, France
[2] CHU Tours, Serv Chirurg Orthoped & Traumatol Infantile, F-37000 Tours, France
[3] Univ Tours, Tours, France
[4] CHU Poitiers, Serv Chirurg Orthoped & Traumatol, Poitiers, France
关键词
Meniscus; Repair; Pediatrics; FasT-Fix; Arthroscopy; Children; ARTHROSCOPIC PARTIAL MENISCECTOMY; FOLLOW-UP; MEDIAL MENISCECTOMY; LIGAMENT INJURIES; AVASCULAR ZONE; YOUNG ATHLETE; REPAIR; KNEE; CHILDREN; TEARS;
D O I
10.1016/j.otsr.2015.12.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Incidence of meniscal lesions is increasing in the pediatric population. Given the harmful impact of meniscectomy, meniscal repair is attempted whenever possible. The present study sought to assess the efficacy of FasT-Fix (Smith and Nephew) all-inside arthroscopic meniscal repair devices in childhood meniscal lesions. The study hypothesis was that functional results would be equivalent to those of other suture techniques. Material and methods: Nineteen patients were assessed following arthroscopic meniscal repair, at a mean 6 years (range: 3-9 years). Mean age was 14.8 years. There was associated ACL tear in 31% of cases. Functional assessment used Lysholm, subjective IKDC, Tegner activity level and KOOS scores. Anatomic assessment of healing used MRI, arthroscopy or CT-arthrography. Results: At last follow-up, the meniscal survival rate was 89.5% (n = 17/19). Functional results were good: Lysholm: 95.7/100; subjective IKDC: 90.7/100; Tegner: 7.64. Imaging found systematic healing. Discussion: All-inside arthroscopic meniscal suture is increasingly used in adults, and can also be implemented in children or adolescents in pediatrics. FasT-Fix (Smith and Nephew) implants, although not always easy to use, ensure a perfectly functional knee and conserve long-term meniscal chondroprotection with a low risk of complications. (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 50 条
  • [31] The incidence of meniscal cyst formation following meniscal repair using the all-inside suture anchor device is comparable to conventional techniques
    Goto, Kazumi
    Sanada, Takaki
    Honda, Eisaburo
    Sameshima, Shin
    Inagawa, Miyu
    Ishida, Yutaro
    Matsuo, Koji
    Kuzuhara, Ryota
    Iwaso, Hiroshi
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (04)
  • [32] An anatomic evaluation of T-Fix suture device placement for arthroscopic all-inside meniscal repair
    Coen, MJ
    Caborn, DNM
    Urban, W
    Nyland, J
    Johnson, DL
    [J]. ARTHROSCOPY, 1999, 15 (03): : 275 - 280
  • [33] Prevalence, development, and factors associated with cyst formation after meniscal repair with the all-inside suture device
    Shozaburo Terai
    Yusuke Hashimoto
    Shinya Yamasaki
    Shinji Takahashi
    Nagakazu Shimada
    Hiroaki Nakamura
    [J]. Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 1261 - 1268
  • [34] Prevalence, development, and factors associated with cyst formation after meniscal repair with the all-inside suture device
    Terai, Shozaburo
    Hashimoto, Yusuke
    Yamasaki, Shinya
    Takahashi, Shinji
    Shimada, Nagakazu
    Nakamura, Hiroaki
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (09) : 1261 - 1268
  • [35] The Biomechanical Performance of the Latest All-Inside Meniscal Repair Devices
    Barber, F. Alan
    Howard, Michael S.
    Ashraf, Wasik
    Spenciner, David B.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (12): : 3001 - 3007
  • [36] A Biomechanical Evaluation of All-Inside 2-Stitch Meniscal Repair Devices With Matched Inside-Out Suture Repair
    Ramappa, Arun J.
    Chen, Alvin
    Hertz, Benjamin
    Wexler, Michael
    Bournissaint, Leandro Grimaldi
    DeAngelis, Joseph P.
    Nazarian, Ara
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (01): : 194 - 199
  • [37] All-inside meniscal repair surgery: factors affecting the outcome
    Majeed, Haroon
    Karuppiah, Saravana Vail
    Sigamoney, Kohila Vani
    Geutjens, Guido
    Straw, Robert G.
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2015, 16 (03) : 245 - 249
  • [38] An arthroscopic repair technique for meniscal tear using a needle and suture: outside-in transfer all-inside repair
    Wang, Zhiqiang
    Xiong, Yan
    Tang, Xin
    Li, Qi
    Zhang, Zhong
    Li, Jian
    Chen, Gang
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [39] A Reduction Method for All-Inside Posterior Horn Meniscal Repair
    Thompson, Simon M.
    Pinczewski, Leo A.
    [J]. ARTHROSCOPY TECHNIQUES, 2015, 4 (05): : E423 - E424
  • [40] Complications with all-inside devices used in reconstructive meniscal surgery
    Wilmes, P.
    Lorbach, O.
    Brogard, P.
    Seil, R.
    [J]. ORTHOPADE, 2008, 37 (11): : 1088 - +