Prevalence, development, and factors associated with cyst formation after meniscal repair with the all-inside suture device

被引:14
|
作者
Terai, Shozaburo [1 ]
Hashimoto, Yusuke [2 ]
Yamasaki, Shinya [3 ]
Takahashi, Shinji [2 ]
Shimada, Nagakazu [4 ]
Nakamura, Hiroaki [2 ]
机构
[1] Osaka City Juso Hosp, Dept Orthopaed Surg, Yodogawa Ku, 2-12-27 Nonaka Kita, Osaka, Osaka 5320034, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Orthopaed Surg, Abeno Ku, 1-4-3 Asahi Machi, Osaka, Osaka 5458585, Japan
[3] Osaka City Gen Hosp, Dept Orthopaed Surg, Miyakojima Ku, 2-13-22 Miyakojima Hondori, Osaka, Osaka 5310031, Japan
[4] Shimada Hosp, Dept Orthopaed Surg, Habikino, Osaka 5830875, Japan
关键词
Meniscus; Meniscal cyst; FasT-Fix; MRI; MEDIAL MENISCUS; ANATOMY; RECONSTRUCTION; COMPLICATIONS; MENISCECTOMY; NERVE; JOINT;
D O I
10.1007/s00402-019-03176-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To investigate the prevalence of cyst formation after using all-inside meniscal repair device and analysed the risk factors associated with it. Methods Between August 2008 and September 2013, 51 menisci of 46 patients were included in the study, 46 menisci of which had concomitant anterior cruciate ligament (ACL) ruptures and had an ACL reconstruction. Magnetic resonance imaging (MRI) of the knee was performed at 3, 6, 12 and 24 months after meniscal surgery. The MRIs were assessed to detect the development of cysts encasing the suture anchors and to evaluate meniscal healing. Statistical analysis was performed using multiple regression analysis. Results Out of the 51 menisci examined, MRI revealed cysts in 15 menisci. Cysts were detected in 3 menisci at 6 months, in 9 menisci at 12 months, and in 3 menisci at 24 months after surgery. Only 3 patients (6.5%) were symptomatic, and cystectomy was performed in 2 of these patients and arthroscopic debridement in the other. Compared with using both the suture device and an inside-out suture repair, using the suture device alone was more likely to be associated with cyst development [odds ratio (OR), 12.04]. The medial meniscus was also significantly more likely to develop a cyst compared with the lateral meniscus (OR, 12.48). There was an increased outcome for the number of device use (P = 0.033). Though it was not statistically significant, the patients with anterior knee laxity (side-to-side difference > 3 mm using a knee arthrometer) were more likely to develop cysts than those without anterior knee laxity (P = 0.06). There were no significant differences between the remaining variables. Conclusions The prevalence of cyst formation around the suture implant was 29%, but most cases were not symptomatic. Significant risk factors for cyst formation included the use of a suture device alone, and a location in the medial meniscus.
引用
收藏
页码:1261 / 1268
页数:8
相关论文
共 50 条
  • [1] Prevalence, development, and factors associated with cyst formation after meniscal repair with the all-inside suture device
    Shozaburo Terai
    Yusuke Hashimoto
    Shinya Yamasaki
    Shinji Takahashi
    Nagakazu Shimada
    Hiroaki Nakamura
    [J]. Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 1261 - 1268
  • [2] Meniscal cyst formation after all-inside meniscal repair
    Lombardo, S
    Eberly, V
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05): : 666 - 667
  • [3] Comparison of new and old all-inside suture devices in meniscal cyst formation rates after meniscal repair
    Takuya Kinoshita
    Yusuke Hashimoto
    Kazuya Nishino
    Yohei Nishida
    Shinji Takahashi
    Hiroaki Nakamura
    [J]. International Orthopaedics, 2022, 46 : 1563 - 1571
  • [4] Comparison of new and old all-inside suture devices in meniscal cyst formation rates after meniscal repair
    Kinoshita, Takuya
    Hashimoto, Yusuke
    Nishino, Kazuya
    Nishida, Yohei
    Takahashi, Shinji
    Nakamura, Hiroaki
    [J]. INTERNATIONAL ORTHOPAEDICS, 2022, 46 (07) : 1563 - 1571
  • [5] The incidence of meniscal cyst formation following meniscal repair using the all-inside suture anchor device is comparable to conventional techniques
    Goto, Kazumi
    Sanada, Takaki
    Honda, Eisaburo
    Sameshima, Shin
    Inagawa, Miyu
    Ishida, Yutaro
    Matsuo, Koji
    Kuzuhara, Ryota
    Iwaso, Hiroshi
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (04)
  • [6] All-inside suture meniscal repair using suture passer
    Uchida, Ryohei
    Horibe, Shuji
    Ohori, Tomoki
    Shino, Konsei
    [J]. ANNALS OF JOINT, 2024, 9
  • [7] All-inside meniscal repair using the RapidLoc device
    Sen, Cengiz
    Asik, Mehmet
    Yumrukcal, Feridun
    Atalar, Ata Can
    Erdil, Mehmet
    Taser, Oemer F.
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 291 - 297
  • [8] All-inside, suture anchor repair for meniscal root tears
    Nam-Hong Choi
    Kyoung-Mo Son
    Brian N. Victoroff
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 430 - 430
  • [9] All-inside, suture anchor repair for meniscal root tears
    Gregory Scott DiFelice
    Hilary Umans
    Eliyahu Englesohn
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 428 - 429
  • [10] All-inside, suture anchor repair for meniscal root tears
    Choi, Nam-Hong
    Son, Kyoung-Mo
    Victoroff, Brian N.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (04) : 430 - 430