In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study

被引:41
|
作者
Shao, Yiping [1 ]
Sun, Xishan [1 ]
Lou, Kai [1 ,2 ]
Zhu, Xiaorong R. [3 ]
Mirkovic, Dragon [3 ]
Poenisch, Falk [3 ]
Grosshans, David [4 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77251 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 13期
关键词
proton radiotherapy; proton beam range; positron emission tomography; in-beam PET imaging; positron activity range; POSITRON-EMISSION-TOMOGRAPHY; CARBON-ION THERAPY; RANGE VERIFICATION; RECONSTRUCTION; DISTRIBUTIONS; FEASIBILITY; SIMULATION; READOUT; SCANNER; SYSTEM;
D O I
10.1088/0031-9155/59/13/3373
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered similar to 50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180 degrees were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A Na-22 disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (<1%) after each beam, due mainly to the neutron exposure of SSPM that increased the dark-count noise. This minor effect was corrected offline with a shifting 350-650 keV energy window for each dataset. The results show a fast converging of activity-ranges measured by the prototype PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.
引用
收藏
页码:3373 / 3388
页数:16
相关论文
共 50 条
  • [41] Characterization of in-beam MR imaging performance during proton beam irradiation
    Hoffmann, A.
    Gantz, S.
    Grossinger, P.
    Karsch, L.
    Pawelke, J.
    Serra, A.
    Smeets, J.
    Schellhammer, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S547 - S548
  • [42] Reconstruction of Dose Distribution in In-beam PET for Carbon Therapy
    Kim, Kwangdon
    Bae, Seungbin
    Lee, Kisung
    Chung, Yonghyun
    An, Sujung
    Joung, Jinhun
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2433 - 2436
  • [43] Aptamers and in-beam PET for advanced diagnosis and therapy optimisation
    Giovanni Lucignani
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 1095 - 1097
  • [44] Aptamers and in-beam PET for advanced diagnosis and therapy optimisation
    Lucignani, Giovanni
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (09) : 1095 - 1097
  • [45] On the detector arrangement for in-beam PET for hadron therapy monitoring
    Crespo, Paulo
    Shakirin, Georgy
    Enghardt, Wolfgang
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (09): : 2143 - 2163
  • [46] Low-Dose, Short-Acquisition, On-Line PET Imaging for Proton Intra-Beam Range Verification
    Yang, D.
    Zhu, X.
    Ma, L.
    Chen, M.
    Park, Y.
    Lu, W.
    Shao, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E222 - E223
  • [47] A simulation study of in-beam visualization system for proton therapy by monitoring scattered protons
    Sato, Shogo
    Yokokawa, Hiromu
    Hosobuchi, Mana
    Kataoka, Jun
    [J]. FRONTIERS IN MEDICINE, 2023, 10
  • [48] First Results From All-Digital PET Dual Heads for In-Beam Beam-On Proton Therapy Monitoring
    Gao, Min
    Chen, Hsien-Hsin
    Chen, Fang-Hsin
    Hong, Ji-Hong
    Hsiao, Ing-Tsung
    Yen, Tzu-Chen
    Mao, Jingfang
    Lu, Jiade J.
    Wang, Weidong
    D'Ascenzo, Nicola
    Xie, Qingguo
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (06) : 775 - 782
  • [49] Identification of Morphological Changes in Head-And-Neck Patients Through In-Beam PET Monitoring in Proton Therapy
    Kraan, A. C.
    Berti, A.
    Retico, A.
    Battistoni, G.
    Cerello, P.
    Del Sarto, D.
    Ferrero, V.
    Fiorina, E.
    Laruina, F.
    Mazzoni, E.
    Morrocchi, M.
    Pennazio, F.
    Rosso, V.
    Sportelli, G.
    Vitolo, V.
    Bisogni, G.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [50] In-vivo range verification analysis with in-beam PET data for patients treated with proton therapy at CNAO
    Moglioni, Martina
    Kraan, Aafke Christine
    Baroni, Guido
    Battistoni, Giuseppe
    Belcari, Nicola
    Berti, Andrea
    Carra, Pietro
    Cerello, Piergiorgio
    Ciocca, Mario
    De Gregorio, Angelica
    De Simoni, Micol
    Del Sarto, Damiano
    Donetti, Marco
    Dong, Yunsheng
    Embriaco, Alessia
    Fantacci, Maria Evelina
    Ferrero, Veronica
    Fiorina, Elisa
    Fischetti, Marta
    Franciosini, Gaia
    Giraudo, Giuseppe
    Laruina, Francesco
    Maestri, Davide
    Magi, Marco
    Magro, Giuseppe
    Malekzadeh, Etesam
    Marafini, Michela
    Mattei, Ilaria
    Mazzoni, Enrico
    Mereu, Paolo
    Mirandola, Alfredo
    Morrocchi, Matteo
    Muraro, Silvia
    Orlandi, Ester
    Patera, Vincenzo
    Pennazio, Francesco
    Pullia, Marco
    Retico, Alessandra
    Rivetti, Angelo
    Rolo, Manuel Dionisio Da Rocha
    Rosso, Valeria
    Sarti, Alessio
    Schiavi, Angelo
    Sciubba, Adalberto
    Sportelli, Giancarlo
    Tampellini, Sara
    Toppi, Marco
    Traini, Giacomo
    Trigilio, Antonio
    Valle, Serena Marta
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12