Characterization of in-beam MR imaging performance during proton beam irradiation

被引:0
|
作者
Hoffmann, A. [1 ,2 ,3 ,4 ]
Gantz, S. [1 ,4 ]
Grossinger, P. [1 ]
Karsch, L. [1 ,4 ]
Pawelke, J. [1 ,4 ]
Serra, A. [5 ]
Smeets, J. [6 ]
Schellhammer, S. [1 ,4 ]
机构
[1] Natl Ctr Radiat Res Oncol, Med Radiat Phys, OncoRay, Dresden, Germany
[2] Tech Univ Dresden, Radiotherapy & Radiat Oncol, Fac Med, Dresden, Germany
[3] Tech Univ Dresden, Radiotherapy & Radiat Oncol, Univ Hosp Carl Gustav Carus, Dresden, Germany
[4] Helmholtz Zentrum Dresden Rossendorf, Radiooncol, OncoRay, Dresden, Germany
[5] Paramed Med Syst, Res & Dev, Genoa, Italy
[6] Ion Beam Applicat SA, Res & Dev, Louvain La Neuve, Belgium
关键词
D O I
10.1016/S0167-8140(18)31296-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-0986
引用
收藏
页码:S547 / S548
页数:2
相关论文
共 50 条
  • [1] Image Performance Characterization of an In-Beam Low-Field Magnetic Resonance Imaging System During Static Proton Beam Irradiation
    Gantz, Sebastian
    Schellhammer, Sonja M.
    Hoffmann, Aswin L.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (03) : 271 - 281
  • [2] Characterization of magnetic interference and image artefacts during simultaneous in-beam MR imaging and proton pencil beam scanning
    Gantz, Sebastian
    Hietschold, Volker
    Hoffmann, Aswin Louis
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [3] Experimental dosimetric characterization of proton pencil beam distortion in a perpendicular magnetic field of an in-beam MR scanner
    Gebauer, Benjamin
    Pawelke, Joerg
    Hoffmann, Aswin
    Luehr, Armin
    [J]. MEDICAL PHYSICS, 2023, 50 (11) : 7294 - 7303
  • [4] Optimization of the in-beam OpenPET detector for carbon beam irradiation
    Nishikido, Fumihiko
    Hirano, Yoshiyuki
    Inadama, Naoko
    Yoshida, Eiji
    Tashima, Hideaki
    Sato, Shinji
    Inaniwa, Taku
    Murayama, Hideo
    Ito, Hiroshi
    Yamaya, Taiga
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3847 - 3849
  • [5] Dosimetry by Means of In-Beam PET with RI Beam Irradiation
    Nakajima, Yasunori
    Hirano, Yoshiyuki
    Tashima, Hideaki
    Yoshida, Eiji
    Sato, Shinji
    Lnaniwa, Taku
    Kohno, Toshiyuki
    Sihver, Lembit
    Yamaya, Taiga
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [6] Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation
    Yamamoto, S.
    Toshito, T.
    Komori, M.
    Watabe, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3717 - 3717
  • [7] First in-beam MR scanner for image-guided proton therapy: beam alignment and magnetic field effects
    Schellhammer, S.
    Karsch, L.
    Smeets, J.
    L'Abbate, C.
    Henrotin, S.
    Van der Kraaij, E.
    Luehr, A.
    Quets, S.
    Pawelke, J.
    Hoffmann, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S318 - S319
  • [8] Characterization of an In-Beam PET Prototype for Proton Therapy With Different Target Compositions
    Attanasi, Francesca
    Belcari, Nicola
    Moehrs, Sascha
    Rosso, Valeria
    Vecchio, Sara
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Lojacono, Piero
    Romano, Francesco
    Lanconelli, Nico
    Del Guerra, Alberto
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 1563 - 1569
  • [9] Luminescence imaging of water during proton-beam irradiation for range estimation
    Yamamoto, Seiichi
    Toshito, Toshiyuki
    Okumura, Satoshi
    Komori, Masataka
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6498 - 6506
  • [10] In-Beam PET Imaging with Depth-Of-Interaction Measurement for Accurate Proton Beam-Range Verification
    Shao, Y.
    Sun, X.
    Lou, K.
    Zhu, X.
    Mirkovic, D.
    Poenisch, F.
    Grosshans, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)