A simulation study of in-beam visualization system for proton therapy by monitoring scattered protons

被引:2
|
作者
Sato, Shogo [1 ]
Yokokawa, Hiromu [1 ]
Hosobuchi, Mana [1 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo, Japan
基金
日本科学技术振兴机构;
关键词
proton therapy; dose range verification; deep learning; scattering protons; CT utilization; scintillation detectors; current readout; CARLO DOSE CALCULATION; PET; EMISSION; DISTRIBUTIONS; VERIFICATION; IRRADIATION; RADIATION; PHYSICS; WATER;
D O I
10.3389/fmed.2023.1038348
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recently, in-beam positron emission tomography (PET) has been actively researched for reducing biological washout effects and dose monitoring during irradiation. However, the positron distribution does not precisely reflect the dose distribution since positron production and ionization are completely different physical processes. Thus, a novel in-beam system was proposed to determine proton dose range by measuring scattered protons with dozens of scintillation detectors surrounding the body surface. While previous studies conducted a preliminary experiment with a simple phantom, we simulated more complex situations in this paper. Especially, we conducted three stepwise simulation studies to demonstrate the feasibility of the proposed method. First, a simple rectangular phantom was reproduced on simulation and irradiated with protons for obtaining current values and Monte Carlo (MC) dose. Next, we trained a deep learning model to estimate 2-dimensional-dose range (2D-DL dose) from measured current values for simulation (A). We simulated plastic scintillators as detectors to measure the scattered protons. Second, a rectangular phantom with an air layer was used, and 3D-DL dose was estimated in simulation (B). Finally, a cylindrical phantom that mimics the human body was used for confirming the estimation quality of the simulation (C). Consequently, the position of the Bragg peak was estimated with an error of 1.0 mm in simulation (A). In addition, the position of the air layer, as well as the verifying peak position with an error of 2.1 mm, was successfully estimated in simulation (B). Although the estimation error of the peak position was 12.6 mm in simulation (C), the quality was successfully further improved to 9.3 mm by incorporating the mass density distribution obtained from the computed tomography (CT). These simulation results demonstrated the potential of the as-proposed verification system. Additionally, the effectiveness of CT utilization for estimating the DL dose was also indicated.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A PET Prototype for "In-Beam" Monitoring of Proton Therapy
    Vecchio, Sara
    Attanasi, Francesca
    Belcari, Nicola
    Camarda, Manuela
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Di Rosa, Francesco
    Lanconelli, Nico
    Moehrs, Sascha
    Rosso, Valeria
    Russo, Giorgio
    Del Guerra, Alberto
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 51 - 56
  • [2] A PET prototype for in-beam monitoring of proton therapy
    Vecchio, Sara
    Attanasi, Francesca
    Belcari, Nicola
    Camarda, Manuela
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Del Guerra, Alberto
    Di Rosa, Francesco
    Lanconelli, Nico
    Moehrs, Sascha
    Rosso, Valeria
    Russo, Giorgio
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1607 - +
  • [3] Experimental study on the feasibility of in-beam PET for accurate monitoring of proton therapy
    Parodi, K
    Pönisch, F
    Enghardt, W
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 778 - 786
  • [4] Monitoring Proton Therapy Through in-Beam PET: An Experimental Phantom Study
    Topi, A.
    Muraro, S.
    Battistoni, G.
    Belcari, N.
    Bisogni, M. G.
    Camarlinghi, N.
    Del Guerra, A.
    Ferrari, A.
    Kopec, R.
    Kraan, A. C.
    Krzempek, D.
    Krzempek, K.
    Morrocchi, M.
    Olko, P.
    Sala, P.
    Sportelli, G.
    Rosso, V.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 194 - 201
  • [5] A new in-beam proton therapy monitoring system based on digital MVT readout
    D'Ascenzo, N.
    Gao, M.
    Chen, Hsien-Hsin
    Chen, Fang-Hsin
    Hong, Ji-Hong
    Hsiao, Ing-Tsung
    Yen, Tzu-Chen
    Wang, Weidong
    Xi, Daoming
    Zhang, Bo
    Xie, Qingguo
    [J]. 2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [6] First tests for an online treatment monitoring system with in-beam PET for proton therapy
    Kraan, A. C.
    Battistoni, G.
    Belcari, N.
    Camarlinghi, N.
    Cappucci, F.
    Ciocca, M.
    Ferrari, A.
    Ferretti, S.
    Mairani, A.
    Molinelli, S.
    Pullia, M.
    Retico, A.
    Sala, P.
    Sportelli, G.
    Del Guerra, A.
    Rosso, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [7] The feasibility of in-beam PET for accurate monitoring of proton therapy:: Results of a comprehensive experimental study
    Parodi, K
    Pönisch, F
    Enghardt, W
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2160 - 2164
  • [8] An in-beam PET system for monitoring ion-beam therapy: test on phantoms using clinical 62 MeV protons
    Camarlinghi, N.
    Sportelli, G.
    Battistoni, G.
    Belcari, N.
    Cecchetti, M.
    Cirrone, G. A. P.
    Cuttone, G.
    Ferretti, S.
    Kraan, A.
    Retico, A.
    Romano, F.
    Sala, P.
    Straub, K.
    Tramontana, A.
    Del Guerra, A.
    Rosso, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [9] Detection of Interfractional Morphological Changes in Proton Therapy: A Simulation and In Vivo Study With the INSIDE In-Beam PET
    Fiorina, Elisa
    Ferrero, Veronica
    Baroni, Guido
    Battistoni, Giuseppe
    Belcari, Nicola
    Camarlinghi, Niccolo
    Cerello, Piergiorgio
    Ciocca, Mario
    De Simoni, Micol
    Donetti, Marco
    Dong, Yunsheng
    Embriaco, Alessia
    Fischetti, Marta
    Franciosini, Gaia
    Giraudo, Giuseppe
    Kraan, Aafke
    Laruina, Francesco
    Luongo, Carmela
    Maestri, Davide
    Magi, Marco
    Magro, Giuseppe
    Malekzadeh, Etesam
    Mancini Terracciano, Carlo
    Marafini, Michela
    Mattei, Ilaria
    Mazzoni, Enrico
    Mereu, Paolo
    Mirabelli, Riccardo
    Mirandola, Alfredo
    Morrocchi, Matteo
    Muraro, Silvia
    Patera, Alessandra
    Patera, Vincenzo
    Pennazio, Francesco
    Retico, Alessandra
    Rivetti, Angelo
    Da Rocha Rolo, Manuel Dionisio
    Rosso, Valeria
    Sarti, Alessio
    Schiavi, Angelo
    Sciubba, Adalberto
    Solfaroli Camillocci, Elena
    Sportelli, Giancarlo
    Tampellini, Sara
    Toppi, Marco
    Traini, Giacomo
    Valle, Serena Marta
    Valvo, Francesca
    Vischioni, Barbara
    Vitolo, Viviana
    [J]. FRONTIERS IN PHYSICS, 2021, 8
  • [10] In-beam PET monitoring of proton therapy: a method for filtering prompt radiation events
    Ma, Qiuhui
    Yang, Zhiyong
    Mu, Dengyun
    Gao, Min
    Zhang, Ruilin
    Wan, Lin
    Qiu, Ao
    Xie, Qingguo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):