Device and technique for extracorporeal blood volume sequestration during hemodialysis

被引:1
|
作者
Wimmer, Juergen
Bachler, Isolde
Haditsch, Bernd
Stadlbauer, Vanessa
Holzer, Herwig
Schneditz, Daniel
机构
[1] Graz Med Univ, Inst Physiol, Ctr Physiol Med, A-8010 Graz, Austria
[2] Graz Med Univ, Div Neurol, Dept Internal Med, A-8010 Graz, Austria
[3] Graz Med Univ, Div Gastroenterol, Dept Internal Med, A-8010 Graz, Austria
关键词
D O I
10.1097/01.mat.0000235812.55055.5b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a technique for a controlled and reversible volume perturbation of the cardiovascular system during hemodialysis. The capacitance of the extracorporeal circulation was modified by an expansion bag, using separate filling and draining lines connected to postpump and prepump sections of the arterial line segment, respectively. The connection to this bag was manually operated by three-way valves. The volume sequestered into the blood bag was continuously measured by a weighing scale. Filling and draining of the expansion bag was measured in eight patients in two subsequent routine dialysis treatments. Four volume shifts were done in each treatment. Filling and draining rates and times depended on extracorporeal blood flow as well as arterial and venous line pressures. Bag inflow and outflow volumes were 215.8 +/- 28.5 ml/min and 221.6 +/- 37.0 ml/min, respectively. The total volume transiently sequestered in the bag was 479.8 +/- 61.3 ml. The duration of the whole test was 4.5 +/- 0.8 minutes. During filling, residual dialyzer blood flow was transiently reduced to 58.5 +/- 21.6 ml/min and the filtration fraction reached 30 +/- 13%. There were no adverse events such as clotting in the blood bag or in the dialyzer. The method provides rapid, reversible, and safe volume shifts between the patient and the extracorporeal circulation with the potential to elicit a hemodynamic response for characterizing the patient during each dialysis treatment.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 50 条
  • [1] Device and technique for extracorporeal blood volume sequestration during hemodialysis (HD)
    Wimmer, J
    Bachler, I
    Haditsch, B
    Stadlbauer, V
    Holzer, H
    Schneditz, D
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 525 - 525
  • [2] Effect of controlled extracorporeal blood cooling on ultrafiltration-induced blood volume changes during hemodialysis
    Schneditz, D
    Martin, K
    Kramer, M
    Kenner, T
    Skrabal, F
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 (06): : 956 - 964
  • [3] Exercise and extracorporeal blood cooling during hemodialysis
    Rosales, Laura M.
    Schneditz, Daniel
    Chmielnicki, Hicha
    Shaw, Kevin
    Levin, Nathan W.
    ASAIO Journal, 44 (05):
  • [4] Exercise and extracorporeal blood cooling during hemodialysis
    Rosales, LM
    Schneditz, D
    Chmielnicki, H
    Shaw, K
    Levin, NW
    ASAIO JOURNAL, 1998, 44 (05) : M574 - M578
  • [5] Effect of controlled extracorporeal blood cooling on ultrafiltration (UF) induced blood volume changes during hemodialysis (HD)
    Schneditz, D
    Martin, K
    Kramer, M
    Kenner, T
    Skrabal, F
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0859 - A0859
  • [6] Blood volume regulation during hemodialysis
    Santoro, A
    Mancini, E
    Paolini, F
    Cavicchioli, G
    Bosetto, A
    Zucchelli, P
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 32 (05) : 739 - 748
  • [7] A New Device to Monitor Blood Volume in Hemodialysis Patients
    Yoshida, Izumi
    Ando, Katsunobu
    Ando, Yasuhiro
    Ookawara, Susumu
    Suzuki, Masayuki
    Furuya, Hiroaki
    Iimura, Osamu
    Takada, Daisuke
    Kajiya, Masaharu
    Komada, Takanori
    Mori, Honami
    Tabei, Kaoru
    THERAPEUTIC APHERESIS AND DIALYSIS, 2010, 14 (06) : 560 - 565
  • [8] Measurement of Cardiac Output and Blood Volume During Hemodialysis with Fluorescent Dye Dilution Technique
    Jean Michel I. Maarek
    Eduardo H. Rubinstein
    Yumei Guo
    Christianne J. Lane
    Vito M. Campese
    Daniel P. Holschneider
    Annals of Biomedical Engineering, 2017, 45 : 580 - 591
  • [9] Measurement of Cardiac Output and Blood Volume During Hemodialysis with Fluorescent Dye Dilution Technique
    Maarek, Jean Michel I.
    Rubinstein, Eduardo H.
    Guo, Yumei
    Lane, Christianne J.
    Campese, Vito M.
    Holschneider, Daniel P.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (03) : 580 - 591
  • [10] Biofeedback in blood volume regulation during hemodialysis
    Santoro, A
    Mancini, E
    NEFROLOGIA, 1997, 17 : 56 - 60