Alternative Placement of Bispectral Index Electrode for Monitoring Depth of Anesthesia during Neurosurgery

被引:0
|
作者
Akavipat, Phuping [1 ]
Hungsawanich, Nate [1 ]
Jansin, Rungruedee [1 ]
机构
[1] Prasat Neurol Inst, Dept Anesthesiol, Bangkok 10400, Thailand
关键词
Bland and Altman analysis; electroencephalogram; instrumentation; equipment; BIS; SENSOR; PERFORMANCE; POSITION; MONTAGE; EVENTS; VALUES; SITE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
In neurosurgery in particular, the recommended placement of electrodes for monitoring depth of anesthesia during surgery sometimes conflicts with the surgical site or patient positioning. Therefore, we proposed this study to evaluate the agreement and correlation of bispectral index values recorded from the usual frontal area and the alternate, post-auricular areas in neurosurgery patients. Thirtyfour patients scheduled for neurosurgery under general anesthesia were included. Bispectral index (BIS) sensors were placed at both the frontal and post-auricular areas. The anesthesia given was clinically adjusted according to the frontal (standard) BIS reading. The BIS values and impedance were recorded; Pearson's correlation and Bland-Altman plots were analyzed. The bias +/- 2SD for the electrode placement before, during, and post-anesthesia were 0 +/- 23.32, 1.5 +/- 10.69, and 2.1 +/- 13.52, while the limits of agreement were -23.3 to 23.3, -12.2 to 9.2, and -17.7 to 13.5, respectively. The correlation coefficient between frontal- and post-auricular-area electrodes was 0.74 with a p-value < 0.001. The post-auricular placement of a BIS electrode is a practical alternative to frontal lobe placement. Nevertheless, proper electrode location is important to minimize error.
引用
下载
收藏
页码:151 / 155
页数:5
相关论文
共 50 条
  • [21] Bispectral index monitoring: comparison of two types of electrode
    Thogersen, B
    Ording, H
    ANAESTHESIA, 2000, 55 (03) : 242 - 246
  • [22] Comparative Evaluation of a New Depth of Anesthesia Index in ConView® System and the Bispectral Index during Total Intravenous Anesthesia: A Multicenter Clinical Trial
    Fu, Yang
    Xu, Tao
    Xie, Keliang
    Wei, Wei
    Gao, Ping
    Nie, Huang
    Deng, Xiaoming
    Wang, Guolin
    Tian, Ming
    Yan, Min
    Dong, Hailong
    Yue, Yun
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [23] Prospective Randomized Trial of Bispectral Index Monitoring of Sedation Depth during Flexible Bronchoscopy
    Fruchter, Oren
    Tirosh, Michal
    Carmi, Uri
    Rosengarten, Dror
    Kramer, Mordechai R.
    RESPIRATION, 2014, 87 (05) : 388 - 393
  • [24] Electromyographic activity on the bispectral index during combined anesthesia
    Panousis, Periklis
    Koch, Thea
    Heller, Axel R.
    ANESTHESIA AND ANALGESIA, 2006, 103 (06): : 1605 - 1605
  • [25] The bispectral index during induction of anesthesia with midazolam and propofol
    Hoffman, WE
    Zsigmond, E
    Albrecht, RF
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1996, 8 (01) : 15 - 20
  • [26] Is the ARX index a more sensitive indicator of anesthetic depth than the bispectral index during sevoflurane/nitrous oxide anesthesia?
    Nishiyama, T
    Matsukawa, T
    Hanaoka, K
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (08) : 1028 - 1032
  • [27] Monitoring anesthesia depth with patient state index during pediatric surgery
    Ricci, Zaccaria
    Robino, Chiara
    Rufini, Paolo
    Cumbo, Silvia
    Cavallini, Sara
    Gobbi, Lorenzo
    Brocchi, Agata
    Serio, Paola
    Romagnoli, Stefano
    PEDIATRIC ANESTHESIA, 2023, 33 (10) : 855 - 861
  • [28] Bispectral index (BIS) analysis of anesthesia depth and anesthetic requirements during partial hepatectomy and liver transplantation
    Janicki, PK
    Higgins, M
    Weitman, R
    Walker, G
    Rodriguez, L
    Beattie, C
    ANESTHESIA AND ANALGESIA, 2000, 90 (02):
  • [29] Evaluation of bispectral index (BIS) for anaesthetic depth monitoring in pigs
    Schmidt, M
    Papp-Jambor, C
    Marx, T
    Schirmer, U
    Reinelt, H
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 2000, 9 (02): : 83 - 86
  • [30] Monitoring depth of anesthesia - With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall
    Drummond, JC
    ANESTHESIOLOGY, 2000, 93 (03) : 876 - 882