Evaluation of bispectral index (BIS) for anaesthetic depth monitoring in pigs

被引:0
|
作者
Schmidt, M [1 ]
Papp-Jambor, C [1 ]
Marx, T [1 ]
Schirmer, U [1 ]
Reinelt, H [1 ]
机构
[1] Univ Ulm, Dept Cardiac Anaesthesia, D-89070 Ulm, Germany
来源
关键词
anaesthesia; xenon; bispectral index; EEG;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Bispectral index (BIS) is a promising method for monitoring anaesthetic depth in humans. Inhalational and intravenous anaesthetics produce dose-dependent effects on electroencephalogram-derived parameters, such as bispectral index (BIS). Significant correlations between decrease of BIS values in humans and end-tidal concentrations of volatile anaesthetics halothane, isoflurane, desflurane and sevoflurane and plasma propofol concentrations have been reported in several investigations. We have investigated the effect of xenon anaesthesia on bispectral index (BIS) in pigs. Materials and Methods: BIS index was measured under total intravenous, xenon and halothane anaesthesia: in 8 pigs. Each animal received 1 MAC halothane before or after xenon anaesthesia in randomized cross over design to eliminate systemic errors. Between xenon and halothane anaesthesia total intravenous anaesthesia was applied to eliminate the effects of the anaesthetic gas first applied. Surgical stimuli were not present during xenon and halothane anaesthesia, surgical preparations were completed in TIVA. BIS levels measured during preparation phase were used as reference values to assure adequate level of anaesthesia. BIS was measured using an BIS EEG monitor (Aspect A 2000, Aspect Medical Systems Inc., Natick, MA, USA). Results: We found no significant difference between BIS scores in anaesthetized pigs with I MAC of halothane or 70% xenon or in total intravenous anaesthesia. In addition, we found no significant difference in BIS during the whole anaesthesia with halothane or xenon. BIS levels during halothane and xenon anaesthesia were comparable to those measured under TIVA and surgical preparation. BIS values remained unchanged during xenon anaesthesis as compared with TIVA and halothane anaesthesia. Conclusion: As a conclusion the BIS EEG is a very promising tool for measuring depth of xenon, halothane and total intravenous anaesthesia also in animals.
引用
收藏
页码:83 / 86
页数:4
相关论文
共 50 条
  • [1] Bispectral Index (BIS) and Entropy monitoring differ in classification of depth of anaesthesia
    Velik-Salchner, C.
    Steger, B.
    Colvin, J.
    Kolbitsch, C.
    Lorenz, I. H.
    Tiefenthaler, W.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 37 - 37
  • [2] Bispectral index and the clinically evaluated anaesthetic depth in dogs
    Bleijenberg, Elise H.
    van Oostrom, Hugo
    Akkerdaas, Louise C.
    Doornenbal, Arie
    Hellebrekers, Ludo J.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2011, 38 (06) : 536 - 543
  • [3] Depth of anesthesia and bispectral index monitoring
    Kissin, I
    ANESTHESIA AND ANALGESIA, 2000, 90 (05): : 1114 - 1117
  • [4] Cardiopulmonary bypass modifies anaesthetic depth as measured by Bispectral Index
    Pettit-Mills, RS
    Smith, DC
    ANAESTHESIA, 2004, 59 (09) : 939 - 939
  • [5] Contribution of bispectral index (bis) monitoring to determination of sedation depth in patients undergoing cardioversion
    Kabukcu, Hanife Karakaya
    Karakas, Mustafa Serkan
    Yanikoglu, Atakan
    Sahyn, Nursel
    Tytyz, Tulin Aydogdu
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 6 - 7
  • [6] Isoflurane anaesthetic depth in goats monitored using the bispectral index of the electroencephalogram
    Antognini, JF
    Wang, XW
    Carstens, E
    VETERINARY RESEARCH COMMUNICATIONS, 2000, 24 (06) : 361 - 370
  • [7] Isoflurane Anaesthetic Depth in Goats Monitored Using the Bispectral Index of the Electroencephalogram
    J.F. Antognini
    X.W. Wang
    E. Carstens
    Veterinary Research Communications, 2000, 24 : 361 - 370
  • [8] Bispectral index (BIS) EEG monitoring in children
    Watcha, MF
    Galinkin, J
    Fazi, LM
    Rose, JB
    ANESTHESIOLOGY, 1999, 91 (3A) : U492 - U492
  • [9] Monitoring sleep depth: analysis of bispectral index (BIS) based on polysomnographic recordings and sleep deprivation
    Gimenez, Sandra
    Romero, Sergio
    Francesc Alonso, Joan
    Angel Mananas, Miguel
    Pujol, Anna
    Baxarias, Pilar
    Maria Antonijoan, Rosa
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (01) : 103 - 110
  • [10] Monitoring sleep depth: analysis of bispectral index (BIS) based on polysomnographic recordings and sleep deprivation
    Sandra Giménez
    Sergio Romero
    Joan Francesc Alonso
    Miguel Ángel Mañanas
    Anna Pujol
    Pilar Baxarias
    Rosa Maria Antonijoan
    Journal of Clinical Monitoring and Computing, 2017, 31 : 103 - 110