Beamformer Source Analysis and Connectivity on Concurrent EEG and MEG Data during Voluntary Movements

被引:36
|
作者
Muthuraman, Muthuraman [1 ]
Hellriegel, Helge [1 ]
Hoogenboom, Nienke [3 ]
Anwar, Abdul Rauf [1 ,2 ]
Mideksa, Kidist Gebremariam [1 ,2 ]
Krause, Holger [3 ]
Schnitzler, Alfons [3 ]
Deuschl, Guenther [1 ]
Raethjen, Jan [1 ]
机构
[1] Univ Kiel, Dept Neurol, Kiel, Germany
[2] Univ Kiel, Inst Circuit & Syst Theory, Kiel, Germany
[3] Univ Dusseldorf, Dept Neurol, Dusseldorf, Germany
来源
PLOS ONE | 2014年 / 9卷 / 03期
关键词
VOLUME CONDUCTION; GRANGER CAUSALITY; COHERENT SOURCES; COMBINING MEG; MOTOR AREAS; BRAIN-AREAS; MODEL; MAGNETOENCEPHALOGRAPHY; LOCALIZATION; SYSTEMS;
D O I
10.1371/journal.pone.0091441
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electroencephalography (EEG) and magnetoencephalography (MEG) are the two modalities for measuring neuronal dynamics at a millisecond temporal resolution. Different source analysis methods, to locate the dipoles in the brain from which these dynamics originate, have been readily applied to both modalities alone. However, direct comparisons and possible advantages of combining both modalities have rarely been assessed during voluntary movements using coherent source analysis. In the present study, the cortical and sub-cortical network of coherent sources at the finger tapping task frequency (2-4 Hz) and the modes of interaction within this network were analysed in 15 healthy subjects using a beamformer approach called the dynamic imaging of coherent sources (DICS) with subsequent source signal reconstruction and renormalized partial directed coherence analysis (RPDC). MEG and EEG data were recorded simultaneously allowing the comparison of each of the modalities separately to that of the combined approach. We found the identified network of coherent sources for the finger tapping task as described in earlier studies when using only the MEG or combined MEG+EEG whereas the EEG data alone failed to detect single sub-cortical sources. The signal-to-noise ratio (SNR) level of the coherent rhythmic activity at the tapping frequency in MEG and combined MEG+EEG data was significantly higher than EEG alone. The functional connectivity analysis revealed that the combined approach had more active connections compared to either of the modalities during the finger tapping (FT) task. These results indicate that MEG is superior in the detection of deep coherent sources and that the SNR seems to be more vital than the sensitivity to theoretical dipole orientation and the volume conduction effect in the case of EEG.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Optimal measurement conditions for spatiotemporal eeg/meg source analysis
    Hilde M. Huizenga
    Dirk J. Heslenfeld
    Peter C. M. Molenaar
    Psychometrika, 2002, 67 : 299 - 313
  • [42] Optimal measurement conditions for spatiotemporal EEG/MEG source analysis
    Huizenga, HM
    Heslenfeld, DJ
    Molenaar, PCM
    PSYCHOMETRIKA, 2002, 67 (02) : 299 - 313
  • [43] A multivariate analysis of evoked responses in EEG and MEG data
    Friston, KJ
    Stephan, KM
    Heather, JD
    Frith, CD
    Ioannides, AA
    Liu, LC
    Rugg, MD
    Vieth, J
    Keber, H
    Hunter, K
    Frackowiak, RSJ
    NEUROIMAGE, 1996, 3 (03) : 167 - 174
  • [44] EEG and MEG Data Analysis in SPM8
    Litvak, Vladimir
    Mattout, Jeremie
    Kiebel, Stefan
    Phillips, Christophe
    Henson, Richard
    Kilner, James
    Barnes, Gareth
    Oostenveld, Robert
    Daunizeau, Jean
    Flandin, Guillaume
    Penny, Will
    Friston, Karl
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2011, 2011
  • [45] MEG/EEG single trial source estimates based on inter-trial priors in the time-frequency domain for source connectivity analysis
    Strohmeier, D.
    Kowalski, M.
    Haueisen, J.
    Hamalainen, M.
    Gramfort, A.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 391 - 391
  • [46] SOURCE ANALYSIS OF MEG ACTIVITIES DURING SLEEP
    UENO, S
    IRAMINA, K
    JOURNAL OF APPLIED PHYSICS, 1991, 69 (08) : 6023 - 6023
  • [47] Incorporating priors for EEG source imaging and connectivity analysis
    Lei, Xu
    Wu, Taoyu
    Valdes-Sosa, Pedro A.
    FRONTIERS IN NEUROSCIENCE, 2015, 9
  • [48] EEG Source Imaging and Connectivity Analysis in Epilepsy Patients
    Lu, Yunfeng
    Worrell, Gregory A.
    Zhang, Huishi C.
    Sohrabpour, Abbas
    He, Bin
    2013 ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, 2013, : 795 - 797
  • [49] Robust Bayesian algorithm for distributed source reconstructions from MEG/EEG data
    Cai, Chang
    Diwakar, Mithun
    Sekihara, Kensuke
    Nagarajan, Srikantan S.
    2019 9TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2019, : 336 - 339
  • [50] A probabilistic algorithm integrating source localization and noise suppression for MEG and EEG data
    Zumer, Johanna M.
    Attias, Hagai T.
    Sekihara, Kensuke
    Nagarajan, Snikantan S.
    NEUROIMAGE, 2007, 37 (01) : 102 - 115