A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry

被引:39
|
作者
MacDougall, N [1 ]
Pitchford, WG
Smith, MA
机构
[1] Cookridge Hosp, Dept Phys Med, Leeds LS16 6QB, W Yorkshire, England
[2] Univ Leeds, Acad Unit Med Phys, Leeds LS2 9NL, W Yorkshire, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 20期
关键词
D O I
10.1088/0031-9155/47/20/201
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-5 1)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43 695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al 1998 Radiother. Oncol. 48 283-91, Farajollahi et al 2000 Br. J. Radiol. 72 1085-92, McJury et al 1999b Phys. Med. Biol. 44 2431-44, Murphy et al 2000b Phys. Med. Biol. 45 835-45, Oldham et al 2001 Med. Phys. 28 1436-45) and 5% for Fricke gel (Chan and Ayyangar 1995b Med. Phys. 22 1171-5). Evidence also points to accuracy worsening at lower dose levels for both gels. The precision data should be viewed with caution as repeated MR measurements were not performed with the same samples. The only precision data for Fricke gels was 1.5% (Johansson Back et al 1998 Phys. Med. Biol. 43 261-76), but for zero dose. In conclusion, despite the amount of published data, sparse research has been undertaken which provides clear evidence of the accuracy and precision for both gels. That which has been published has used higher doses than would be routine in radiotherapy. The basic radiation dosimeter qualities of accuracy and precision have yet to be fully quantified for polymer and Fricke gels at clinically relevant dose levels.
引用
收藏
页码:R107 / R121
页数:15
相关论文
共 50 条
  • [41] Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry
    Watanabe, Y.
    Warmington, L.
    Gopishankar, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3492 - 3492
  • [42] On the accuracy of monomer/polymer gel dosimetry in the proximity of a high-dose-rate 192Ir source
    De Deene, YH
    Reynaert, N
    De Wagter, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2801 - 2825
  • [43] Comparison of graphite-to-water absorbed-dose transfers for Co-60 photon beams using ionometry and Fricke dosimetry
    Chauvenet, B
    Baltes, D
    Delaunay, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11): : 2053 - 2063
  • [44] Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry
    Watanabe, Y
    Mooij, R
    Perera, GM
    Maryanski, MJ
    MEDICAL PHYSICS, 2004, 31 (05) : 975 - 984
  • [45] MR based polymer gel dosimetry (MRPD) versus film dosimetry using dose modulation transfer function (DMTF)
    Alam, N. Riyahi
    Takavar, A.
    Moghadam, M.
    Haghgoo, S.
    Firooznia, K.
    Hadad, P.
    Pourfallah, T. A.
    Mohammadi, E.
    Nedaei, A.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 44 - +
  • [46] Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation
    Karlsson, A.
    Gustavsson, H.
    Mansson, S.
    McAuley, K. B.
    Baeck, S. A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4697 - 4706
  • [47] Improved accuracy in radiotherapy dosimetry of high-energy photon and electron beam using optically stimulated luminescence
    Yukihara, E.
    Mardirossian, G.
    Mirzasadeghi, M.
    Guduru, S.
    Ahmad, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2458 - 2458
  • [48] Intercomparison of absorbed dose to water measurements for 60Co gamma rays using Fricke, alanine and radiochromic dye film dosimetry
    Villarreal-Barajas, JE
    González-Martínez, PR
    Ureña-Nuñez, F
    Martínez-Ayala, L
    Tovar-Muñoz, VM
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A449 - A451
  • [49] Intercomparison of absorbed dose to water measurements for 60Co gamma rays using fricke, alanine and radiochromic dye film dosimetry
    Villarreal-Barajas, JE
    González-Martinez, PR
    Ureña-Nuñez, F
    Martínez-Ayala, L
    Tovar-Muñoz, VM
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 449 - 451
  • [50] MRI-based iPAGAT polymer gel dosimetry using fast recovery spin echo sequences
    Fujino, K.
    Ono, K.
    Hayashi, S.
    Sasaki, K.
    Hioki, K.
    Miyazawa, M.
    Akagi, Y.
    Hirokawa, Y.
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305