MR based polymer gel dosimetry (MRPD) versus film dosimetry using dose modulation transfer function (DMTF)

被引:0
|
作者
Alam, N. Riyahi [1 ]
Takavar, A. [1 ,4 ]
Moghadam, M. [1 ]
Haghgoo, S. [2 ]
Firooznia, K. [3 ]
Hadad, P. [4 ]
Pourfallah, T. A. [1 ]
Mohammadi, E. [4 ]
Nedaei, A.
机构
[1] Med Sci Univ Tehran, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Minist Hlth & Higher educ, Dept Pharmaceut Chem, Food & Drug Labs, Tehran, Iran
[3] Univ Tehran, Dept Radiol & Med Sci, Tehran, Iran
[4] Univ Tehran, Radiat Oncol Ctr Med Sci, Tehran, Iran
来源
2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS | 2007年
关键词
DMTF; film densitometry; polymer gel dosimeter; spatial resolution;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Precise methods of modern radiation therapy such as intensity modulated radiotherapy (IMRT), brachytherapy (BT) and high LET irradiation allow for high dose localization in volumes of a few mm3. However, most dosimetry methods-ionization chambers, TLD arrangements or silicon detectors, for example-are not capable of detecting sub-mm dose variations or do not allow for simple dose imaging. Magnetic resonance based polymer dosimetry (MRPD) appears to be well suited to three-dimensional high resolution relative dosimetry but the spatial resolution based on a systematic modulation transfer function (MTF) approach has not yet been investigated. In this study a theoretical construct for addressing the spatial resolution in different dose imaging systems, i.e. the dose modulation transfer function (DMTF) approach, have been used. The absorption grid is made of brass, which offers a good compromise between effective absorption necessary to obtain sufficient modulation and easy mechanical processing to obtain the fine grid structures. Quasi-periodic slits at lateral width of about 280, 525 and 1125 mu m were sawed by means of fine saw blades in the 8 mm thick brass absorber material. The modulated dose is detected by the polymer gel and then, for film dosimetry the polymer gel is replaced by a film layer which was located under the absorption grid. We concluded that the DMTF in high frequencies is related to the imaging system, and with the current imaging system the spatial resolution in film densitometry and MRPD for 280 mu m resolution is nearly the same.
引用
收藏
页码:44 / +
页数:2
相关论文
共 33 条
  • [1] High resolution MR based polymer dosimetry versus film densitometry:: a systematic study based on the modulation transfer function approach
    Berg, A
    Pernkopf, M
    Waldhäusl, C
    Schmidt, W
    Moser, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (17): : 4087 - 4108
  • [2] Magnetization transfer proportion: a simplified measure of dose response for polymer gel dosimetry
    Whitney, Heather M.
    Gochberg, Daniel F.
    Gore, John C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24): : 7107 - 7124
  • [3] Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry
    Pavoni, J. F.
    Pike, T. L.
    Snow, J.
    DeWerd, L.
    Baffa, O.
    MEDICAL PHYSICS, 2012, 39 (05) : 2877 - 2884
  • [4] The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach
    Bayreder, Christian
    Schoen, Robert
    Wieland, M.
    Georg, Dietmar
    Moser, Ewald
    Berg, Andreas
    MEDICAL PHYSICS, 2008, 35 (05) : 1756 - 1769
  • [5] Measurement of 3D dose distributions and DVH of IMRT treatment plans using MR based gel Dosimetry
    Parker, W
    Brodeur, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1263 - 1264
  • [6] Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation
    Karlsson, A.
    Gustavsson, H.
    Mansson, S.
    McAuley, K. B.
    Baeck, S. A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4697 - 4706
  • [7] Investigation of lung tumour peripheral doses using normoxic polymer gel and film dosimetry techniques
    Venning, A.
    Chandroth, M. Mundayadan
    Chick, B.
    Waller, B.
    Morgan, C.
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [8] Investigation of dose characteristics in three-dimensional MAGAT-type polymer gel dosimetry with MSE MR imaging
    Lee, Jason J. S.
    Tsai, Chia-Jung
    Lo, Man-Kuok
    Huan, Yung-Hui
    Chen, Chien-Chuan
    Wu, Jay
    Tyan, Yeu-Sheng
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (10): : 2199 - 2202
  • [9] Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry
    Wuu, Cheng-Shie
    Xu, Y.
    MEDICAL PHYSICS, 2006, 33 (05) : 1412 - 1419
  • [10] Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources
    Sang-Young Kim
    Hyeon-Man Baek
    Jung-Hoon Lee
    Dae-Hyun Kim
    Jin-Young Jung
    Do-Wan Lee
    Jung-Whan Min
    Ji-Yeon Park
    Seu-Ran Lee
    Bo-Young Choe
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 533 - 541