MR based polymer gel dosimetry (MRPD) versus film dosimetry using dose modulation transfer function (DMTF)

被引:0
|
作者
Alam, N. Riyahi [1 ]
Takavar, A. [1 ,4 ]
Moghadam, M. [1 ]
Haghgoo, S. [2 ]
Firooznia, K. [3 ]
Hadad, P. [4 ]
Pourfallah, T. A. [1 ]
Mohammadi, E. [4 ]
Nedaei, A.
机构
[1] Med Sci Univ Tehran, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Minist Hlth & Higher educ, Dept Pharmaceut Chem, Food & Drug Labs, Tehran, Iran
[3] Univ Tehran, Dept Radiol & Med Sci, Tehran, Iran
[4] Univ Tehran, Radiat Oncol Ctr Med Sci, Tehran, Iran
来源
2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS | 2007年
关键词
DMTF; film densitometry; polymer gel dosimeter; spatial resolution;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Precise methods of modern radiation therapy such as intensity modulated radiotherapy (IMRT), brachytherapy (BT) and high LET irradiation allow for high dose localization in volumes of a few mm3. However, most dosimetry methods-ionization chambers, TLD arrangements or silicon detectors, for example-are not capable of detecting sub-mm dose variations or do not allow for simple dose imaging. Magnetic resonance based polymer dosimetry (MRPD) appears to be well suited to three-dimensional high resolution relative dosimetry but the spatial resolution based on a systematic modulation transfer function (MTF) approach has not yet been investigated. In this study a theoretical construct for addressing the spatial resolution in different dose imaging systems, i.e. the dose modulation transfer function (DMTF) approach, have been used. The absorption grid is made of brass, which offers a good compromise between effective absorption necessary to obtain sufficient modulation and easy mechanical processing to obtain the fine grid structures. Quasi-periodic slits at lateral width of about 280, 525 and 1125 mu m were sawed by means of fine saw blades in the 8 mm thick brass absorber material. The modulated dose is detected by the polymer gel and then, for film dosimetry the polymer gel is replaced by a film layer which was located under the absorption grid. We concluded that the DMTF in high frequencies is related to the imaging system, and with the current imaging system the spatial resolution in film densitometry and MRPD for 280 mu m resolution is nearly the same.
引用
收藏
页码:44 / +
页数:2
相关论文
共 33 条
  • [21] Dosimetry of small photon fields in the presence of bone heterogeneity using MAGIC polymer gel, Gafchromic film, and Monte Carlo simulation
    Parwaie, Wrya
    Geraily, Ghazale
    Mehri-Kakavand, Ghazal
    Babaloui, Somayyeh
    Rezvani, Samira
    Pursamimi, Mohamad
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (02) : 226 - 234
  • [22] Differential dose volume histograms of Gamma Knife in the presence of inhomogeneities using MRI-polymer gel dosimetry and MC simulation
    Pourfallah, Tayyeb Allahverdi
    Allahverdi, Mahmoud
    Alam, Nader Riahi
    Ay, Mohammad-Reza
    Zahmatkesh, Mohammad-Hasan
    MEDICAL PHYSICS, 2009, 36 (07) : 3002 - 3012
  • [23] Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry"
    MacDougall, ND
    Pitchford, WG
    Smith, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (04): : L19 - L22
  • [24] Dose uncertainty and resolution of polymer gel dosimetry using an MRI guided radiation therapy system's onboard 0.35 T scanner
    Maraghechi, Borna
    Gach, H. Michael
    Setianegara, Jufri
    Yang, Deshan
    Li, H. Harold
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 8 - 12
  • [25] The Feasibility of Using Polymer Gel Dosimetry to Measure the Dose Around Thin High Z Materials Irradiated with High Energy Photon Beams
    Warmington, L.
    Watanabe, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3505 - 3506
  • [26] Characteristic study of a novel polymer gel for Tc-99m nuclide dose gradient dosimetry using an optical CT scanner
    Yu, Bi-Wei
    Chu, Chien-Hau
    Chang, Yuan-Jen
    Hsieh, Bor-Tsung
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [27] VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Goto, T.
    Akahane, K.
    Ota, H.
    Tsukagoshi, S.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 508 - 517
  • [28] Validation of 4D dose calculation using an independent motion monitoring by the calypso tracking system and 3D polymer gel dosimetry
    Mann, P.
    Saito, N.
    Lang, C.
    Runz, A.
    Johnen, W.
    Witte, M.
    Schmitt, D.
    Karger, C. P.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [29] Toward "on-line" X-ray computed tomography-based dosimetry using a new polymer gel with rapid response
    Tachibana, Hidenobu
    Oshika, Riki
    Tachibana, Rie
    Seki, Kazuya
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [30] Investigation of target dose conformity using normoxic polymer gel dosimetry techniques: A clinical example of 12th thoracic vertebrae SBRT treatment with VMAT
    Yenning, A.
    Chandrothl, M. Mundayadan
    Morgan, C.
    Roberts, M.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167