A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry

被引:39
|
作者
MacDougall, N [1 ]
Pitchford, WG
Smith, MA
机构
[1] Cookridge Hosp, Dept Phys Med, Leeds LS16 6QB, W Yorkshire, England
[2] Univ Leeds, Acad Unit Med Phys, Leeds LS2 9NL, W Yorkshire, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 20期
关键词
D O I
10.1088/0031-9155/47/20/201
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-5 1)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43 695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al 1998 Radiother. Oncol. 48 283-91, Farajollahi et al 2000 Br. J. Radiol. 72 1085-92, McJury et al 1999b Phys. Med. Biol. 44 2431-44, Murphy et al 2000b Phys. Med. Biol. 45 835-45, Oldham et al 2001 Med. Phys. 28 1436-45) and 5% for Fricke gel (Chan and Ayyangar 1995b Med. Phys. 22 1171-5). Evidence also points to accuracy worsening at lower dose levels for both gels. The precision data should be viewed with caution as repeated MR measurements were not performed with the same samples. The only precision data for Fricke gels was 1.5% (Johansson Back et al 1998 Phys. Med. Biol. 43 261-76), but for zero dose. In conclusion, despite the amount of published data, sparse research has been undertaken which provides clear evidence of the accuracy and precision for both gels. That which has been published has used higher doses than would be routine in radiotherapy. The basic radiation dosimeter qualities of accuracy and precision have yet to be fully quantified for polymer and Fricke gels at clinically relevant dose levels.
引用
收藏
页码:R107 / R121
页数:15
相关论文
共 50 条
  • [11] Evaluation of dose delivery accuracy of Gamma Knife by polymer gel dosimetry
    Watanabe, Yoichi
    Akimitsu, Tomohide
    Hirokawa, Yutaka
    Mooij, Rob B.
    Perera, G. Mark
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03): : 133 - 142
  • [12] Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements
    Bäck, SÅJ
    Medin, J
    Magnusson, P
    Olsson, P
    Grusell, E
    Olsson, LE
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : 1983 - 1996
  • [13] Validation of complex radiotherapy techniques using polymer gel dosimetry
    Karger, Christian P.
    Elter, Alina
    Dorsch, Stefan
    Mann, Philipp
    Pappas, Evangelos
    Oldham, Mark
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (06):
  • [14] Mycosis Fungoides electron beam absorbed dose distribution using Fricke xylenol gel dosimetry
    da Silveira, Michely C.
    Sampaio, Francisco G. A.
    Petchevist, Paulo C. D.
    de Oliveira, Andre L.
    de Almeida, Adelaide
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24): : 3137 - 3140
  • [15] Fricke and polymer gel 2D dosimetry validation using Monte Carlo simulation
    Vedelago, J.
    Chacon Obando, D.
    Malano, F.
    Conejeros, R.
    Figueroa, R.
    Garcia, D.
    Gonzalez, G.
    Romero, M.
    Santibanez, M.
    Strumia, M. C.
    Velasquez, J.
    Mattea, F.
    Valente, M.
    RADIATION MEASUREMENTS, 2016, 91 : 54 - 64
  • [16] Noise in polymer gel measurements using MRI
    Low, DA
    Markman, J
    Dempsey, JF
    Mutic, S
    Oldham, M
    Venkatesan, R
    Haacke, EM
    Purdy, JA
    MEDICAL PHYSICS, 2000, 27 (08) : 1814 - 1817
  • [17] Gel dosimetry measurements and Monte Carlo modeling for external radiotherapy photon beams comparison with a treatment planning system dose distribution
    Valente, M.
    Aon, E.
    Brunetto, A.
    Castellano, G.
    Gallivanone, F.
    Gambarini, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 497 - 501
  • [18] Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy
    Tavares, P. V. S.
    Diniz, R. E.
    Rodrigues Jr, O.
    Campos, L. L.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 224
  • [19] Relative output factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry
    Pappas, E
    Petrokokkinos, L
    Angelopoulos, A
    Maris, TG
    Kozicki, M
    Dalezios, I
    Kouloulias, V
    MEDICAL PHYSICS, 2005, 32 (06) : 1513 - 1520
  • [20] Dose sensitivity modification in polymer gel dosimeters improves the accuracy of optical CT scanning for gel dosimetry
    Maryanski, MJ
    Xu, Y
    Wuu, CS
    MEDICAL PHYSICS, 2003, 30 (06) : 1478 - 1478