Feasibility of Motion Compensation using Inertial Measurement in C-arm CT

被引:0
|
作者
Maier, Jennifer [1 ]
Aichert, Andre [1 ]
Mehringer, Wolfgang [1 ]
Bier, Bastian [1 ]
Eskofier, Bjoern [1 ]
Levenston, Marc [2 ]
Gold, Garry [2 ]
Fahrig, Rebecca [3 ]
Bonaretti, Serena [2 ]
Maier, Andreas [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Dept Comp Sci, Erlangen, Germany
[2] Stanford Univ, Stanford, CA 94305 USA
[3] Siemens Healthcare GmbH, Erlangen, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
C-arm cone-beam CT (CBCT) systems are highly flexible regarding patient position and scan trajectory, which enables scanning a subject's knee joint under weight-bearing conditions. This is of interest, since the knee joint has shown to have different properties under load. However, involuntary subject motion during these acquisitions results in motion artifacts in the reconstruction and thereby degrades image quality noticeably. A current state-of-the-art approach to correct for this motion tracks fiducial markers attached to the knee. However, the marker placement is tedious and time-consuming. To overcome this issue, in this work the feasibility of a novel approach for motion correction based on an Inertial Measurement Unit (IMU) attached to the subject is investigated. In a study, a moved pumpkin phantom with attached fiducial markers is scanned four times by a C-arm CBCT system moving on a horizontal trajectory. Simultaneously, the phantom's motion is recorded by an attached IMU measuring acceleration and angular velocity. The IMU measurements are validated against the motion estimates of the fiducial marker-based approach, which are transformed to the IMU's coordinate system beforehand. While the rotational signals show average correlations of up to 0.85, the translational signals do not show similarity, except for one axis with an average correlation of 0.75. A spectral analysis reveals that the frequencies of the C-arm movement during scanning overlap with those of the phantom motion. While the C-arm movement is estimated by the marker-based approach, it is not measured by the IMU, preventing a valid comparison of the signals with each other. Although these initial results indicate some challenges for further work, they also already show the potential of the IMU-based motion tracking.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Respiratory Motion Compensation for C-Arm CT Liver Imaging
    Sindel, Aline
    Boegel, Marco
    Maier, Andreas
    Fahrig, Rebecca
    Hornegger, Joachim
    Doerfler, Arnd
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 221 - 226
  • [2] Motion Compensation Using Range Imaging in C-Arm Cone-Beam CT
    Bier, Bastian
    Unberath, Mathias
    Geimer, Tobias
    Maier, Jennifer
    Gold, Garry
    Levenston, Marc
    Fahrig, Rebecca
    Maier, Andreas
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 561 - 570
  • [3] Prostate Brachytherapy Seed Reconstruction Using C-Arm Rotation Measurement and Motion Compensation
    Dehghan, Ehsan
    Lee, Junghoon
    Moradi, Mehdi
    Wen, Xu
    Fichtinger, Gabor
    Salcudean, Septimiu E.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT I, 2010, 6361 : 283 - +
  • [4] Rigid Motion Compensation in Interventional C-arm CT Using Consistency Measure on Projection Data
    Frysch, Robert
    Rose, Georg
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I, 2015, 9349 : 298 - 306
  • [5] Technical Feasibility of CT Perfusion using a C-Arm CBCT System
    Xu, Min
    Tang, Jie
    Royalty, Kevin
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [6] Automatic Motion Estimation and Compensation Framework for Weight-bearing C-arm CT scans using Fiducial Markers
    Mueller, K.
    Berger, M.
    Choi, J. -H.
    Maier, A.
    Fahrig, R.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 58 - 61
  • [7] Respiratory Motion Compensation Using Diaphragm Tracking for Cone-Beam C-Arm CT: A Simulation and a Phantom Study
    Boegel, Marco
    Hofmann, Hannes G.
    Hornegger, Joachim
    Fahrig, Rebecca
    Britzen, Stefan
    Maier, Andreas
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2013, 2013
  • [8] Cardiac C-Arm CT: A Unified Framework for Motion Estimation and Dynamic CT
    Pruemmer, Marcus
    Hornegger, Joachim
    Lauritsch, Guenter
    Wigstroem, Lars
    Girard-Hughes, Erin
    Fahrig, Rebecca
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1836 - 1849
  • [9] Feasibility of Myocardial Perfusion Assessment by the Novel C-Arm CT Angiography
    Rittger, Harald
    Sinha, Anil
    Lauritsch, Guenter
    Rieber, Johannes
    Brachmann, Johannes
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B165 - B165
  • [10] Three-dimensional CT with a modified C-arm image intensifier: Feasibility
    Linsenmaier, U
    Rock, C
    Euler, E
    Wirth, S
    Brandl, R
    Kotsianos, D
    Mutschler, W
    Pfeifer, KJ
    RADIOLOGY, 2002, 224 (01) : 286 - 292