Feasibility of Motion Compensation using Inertial Measurement in C-arm CT

被引:0
|
作者
Maier, Jennifer [1 ]
Aichert, Andre [1 ]
Mehringer, Wolfgang [1 ]
Bier, Bastian [1 ]
Eskofier, Bjoern [1 ]
Levenston, Marc [2 ]
Gold, Garry [2 ]
Fahrig, Rebecca [3 ]
Bonaretti, Serena [2 ]
Maier, Andreas [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Dept Comp Sci, Erlangen, Germany
[2] Stanford Univ, Stanford, CA 94305 USA
[3] Siemens Healthcare GmbH, Erlangen, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
C-arm cone-beam CT (CBCT) systems are highly flexible regarding patient position and scan trajectory, which enables scanning a subject's knee joint under weight-bearing conditions. This is of interest, since the knee joint has shown to have different properties under load. However, involuntary subject motion during these acquisitions results in motion artifacts in the reconstruction and thereby degrades image quality noticeably. A current state-of-the-art approach to correct for this motion tracks fiducial markers attached to the knee. However, the marker placement is tedious and time-consuming. To overcome this issue, in this work the feasibility of a novel approach for motion correction based on an Inertial Measurement Unit (IMU) attached to the subject is investigated. In a study, a moved pumpkin phantom with attached fiducial markers is scanned four times by a C-arm CBCT system moving on a horizontal trajectory. Simultaneously, the phantom's motion is recorded by an attached IMU measuring acceleration and angular velocity. The IMU measurements are validated against the motion estimates of the fiducial marker-based approach, which are transformed to the IMU's coordinate system beforehand. While the rotational signals show average correlations of up to 0.85, the translational signals do not show similarity, except for one axis with an average correlation of 0.75. A spectral analysis reveals that the frequencies of the C-arm movement during scanning overlap with those of the phantom motion. While the C-arm movement is estimated by the marker-based approach, it is not measured by the IMU, preventing a valid comparison of the signals with each other. Although these initial results indicate some challenges for further work, they also already show the potential of the IMU-based motion tracking.
引用
收藏
页数:3
相关论文
共 50 条
  • [11] Evaluating the Feasibility of C-arm CT for Brain Perfusion Imaging: An in vitro Study
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [12] Interventional heart wall motion analysis with cardiac C-arm CT systems
    Mueller, Kerstin
    Maier, Andreas K.
    Zheng, Yefeng
    Wang, Yang
    Lauritsch, Guenter
    Schwemmer, Chris
    Rohkohl, Christopher
    Hornegger, Joachim
    Fahrig, Rebecca
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (09): : 2265 - 2284
  • [13] Myocardial perfusion assessment using C-arm CT angiography
    Rieber, J.
    Sinha, A.
    Schmidt, M.
    Lauritsch, G.
    Koenig, A.
    Klauss, V.
    Rittger, H.
    EUROPEAN HEART JOURNAL, 2010, 31 : 578 - 578
  • [14] C-arm distortion correction using patient CT as a fiducial
    Chintalapani, Gouthami
    Taylor, Russell H.
    2007 4TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING : MACRO TO NANO, VOLS 1-3, 2007, : 1180 - 1183
  • [15] Range Imaging for Motion Compensation in C-Arm Cone-Beam CT of Knees under Weight-Bearing Conditions
    Bier, Bastian
    Ravikumar, Nishant
    Unberath, Mathias
    Levenston, Marc
    Gold, Garry
    Fahrig, Rebecca
    Maier, Andreas
    JOURNAL OF IMAGING, 2018, 4 (01)
  • [16] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [17] C-Arm CT Measurement of Cerebral Blood Volume: An Experimental Study in Canines
    Ahmed, A. S.
    Zellerhoff, M.
    Strother, C. M.
    Pulfer, K. A.
    Redel, T.
    Deuerling-Zheng, Y.
    Royalty, K.
    Consigny, D.
    Niemann, D. B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (05) : 917 - 922
  • [18] CT Imaging with a mobile C-arm prototype
    Cheryauka, Arvi
    Tubbs, Dave
    Langille, Vinton
    Kalya, Prabhanjana
    Smith, Brady
    Cherone, Rocco
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [19] Effect of hierarchical deformable motion compensation on image enhancement for DSA acquired via C-ARM
    Wei, Liyang
    Shen, Dinggang
    Kumar, Dinesh
    Turlapati, Ram
    Suri, Jasjit S.
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS VI, 2008, 6812
  • [20] Adrenal vein sampling with C-arm CT
    Kinnison, Malonnie
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (01) : 153 - 153