Feasibility of Motion Compensation using Inertial Measurement in C-arm CT

被引:0
|
作者
Maier, Jennifer [1 ]
Aichert, Andre [1 ]
Mehringer, Wolfgang [1 ]
Bier, Bastian [1 ]
Eskofier, Bjoern [1 ]
Levenston, Marc [2 ]
Gold, Garry [2 ]
Fahrig, Rebecca [3 ]
Bonaretti, Serena [2 ]
Maier, Andreas [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Dept Comp Sci, Erlangen, Germany
[2] Stanford Univ, Stanford, CA 94305 USA
[3] Siemens Healthcare GmbH, Erlangen, Germany
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
C-arm cone-beam CT (CBCT) systems are highly flexible regarding patient position and scan trajectory, which enables scanning a subject's knee joint under weight-bearing conditions. This is of interest, since the knee joint has shown to have different properties under load. However, involuntary subject motion during these acquisitions results in motion artifacts in the reconstruction and thereby degrades image quality noticeably. A current state-of-the-art approach to correct for this motion tracks fiducial markers attached to the knee. However, the marker placement is tedious and time-consuming. To overcome this issue, in this work the feasibility of a novel approach for motion correction based on an Inertial Measurement Unit (IMU) attached to the subject is investigated. In a study, a moved pumpkin phantom with attached fiducial markers is scanned four times by a C-arm CBCT system moving on a horizontal trajectory. Simultaneously, the phantom's motion is recorded by an attached IMU measuring acceleration and angular velocity. The IMU measurements are validated against the motion estimates of the fiducial marker-based approach, which are transformed to the IMU's coordinate system beforehand. While the rotational signals show average correlations of up to 0.85, the translational signals do not show similarity, except for one axis with an average correlation of 0.75. A spectral analysis reveals that the frequencies of the C-arm movement during scanning overlap with those of the phantom motion. While the C-arm movement is estimated by the marker-based approach, it is not measured by the IMU, preventing a valid comparison of the signals with each other. Although these initial results indicate some challenges for further work, they also already show the potential of the IMU-based motion tracking.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
    Pruemmer, M.
    Wigstroem, L.
    Hornegger, J.
    Boese, J.
    Lauritsch, G.
    Strobel, N.
    Fahrig, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2620 - 2628
  • [22] Effect of respiratory motion on abdominal C-arm CT angiography using the 4D NCAT phantom
    Fung, G. S. K.
    Segars, W. P.
    Geschwind, J. -F. H.
    Tsui, B. M. W.
    Taguchi, K.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4536 - +
  • [23] Image artefact propagation in motion estimation and reconstruction in interventional cardiac C-arm CT
    Mueller, K.
    Maier, A. K.
    Schwemmer, C.
    Lauritsch, G.
    De Buck, S.
    Wielandts, J-Y
    Hornegger, J.
    Fahrig, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12): : 3121 - 3138
  • [24] Truncation Correction for VOI C-arm CT using Scattered Radiation
    Bier, Bastian
    Maier, Andreas
    Hofmann, Hannes G.
    Schwemmer, Chris
    Xia, Yan
    Struffert, Tobias
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [25] Image-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees
    Unberath, Mathias
    Choi, Jang-Hwan
    Berger, Martin
    Maier, Andreas
    Fahrig, Rebecca
    MEDICAL IMAGING 2015: IMAGE PROCESSING, 2015, 9413
  • [26] Detection of pulmonary nodules by C-arm CT using a phantom lung: comparison with CT
    Higashihara, Hiroki
    Osuga, Keigo
    Azuma, Takeo
    Nakazawa, Tetsuro
    Yanagawa, Masahiro
    Kikuyama, Ayano
    Maeda, Noboru
    Tomiyama, Noriyuki
    ACTA RADIOLOGICA, 2011, 52 (09) : 964 - 968
  • [27] 3D C-arm as an alternative modality to CT in postmortem imaging:: Technical feasibility
    Pohlenz, Philipp
    Blessmann, Marco
    Oesterhelweg, Lars
    Habermann, Christan R.
    Begemann, Philipp G. C.
    Schmidgunst, Christian
    Blake, Felix
    Schulze, Dirk
    Pueschel, Klaus
    Schmelzle, Rainer
    Heiland, Max
    FORENSIC SCIENCE INTERNATIONAL, 2008, 175 (2-3) : 134 - 139
  • [28] Rotational micro-CT using a clinical C-arm angiography gantry
    Patel, V.
    Hoffmann, K. R.
    Ionita, C. N.
    Keleshis, C.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL PHYSICS, 2008, 35 (10) : 4757 - 4764
  • [29] Statistical model registration for a C-arm CT system
    Fleute, M
    Desbat, L
    Martin, R
    Lavallée, S
    Defrise, M
    Liu, X
    Taylor, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1667 - 1670
  • [30] C-arm CT for planning and guidance of extrahepatic embolizations
    Wacker, F. K.
    Meissner, O. A.
    Meyer, B. C.
    RADIOLOGE, 2009, 49 (09): : 842 - 847