Image quality and dose assessment in digital breast tomosynthesis: A Monte Carlo study

被引:16
|
作者
Baptista, M. [1 ]
Di Maria, S. [1 ]
Oliveira, N. [2 ]
Matela, N. [2 ]
Janeiro, L. [2 ]
Almeida, P. [2 ]
Vaz, P. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, Ctr Ciencias & Tecnol Nucl, P-2695066 Bobadela Lrs, Portugal
[2] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, P-1749016 Lisbon, Portugal
关键词
Digital breast tomosynthesis; Image quality; Signal difference to noise ratio; Mean glandular dose; Monte Carlo simulations; TO-NOISE RATIO; MAMMOGRAPHY; SIMULATION; OPTIMIZATION; POPULATION; DETECTORS; CONTRAST; SYSTEM;
D O I
10.1016/j.radphyschem.2013.12.036
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Mammography is considered a standard technique for the early detection of breast cancer. However, its sensitivity is limited essentially due to the issue of the overlapping breast tissue. This limitation can be partially overcome, with a relatively new technique, called digital breast tomosynthesis (DBT). For this technique, optimization of acquisition parameters which maximize image quality, whilst complying with the ALARA principle, continues to be an area of considerable research. The aim of this work was to study the best quantum energies that optimize the image quality with the lowest achievable dose in DBT and compare these results with the digital mammography (DM) ones. Monte Carlo simulations were performed using the state-of-the-art computer program MCNPX 2.7.0 in order to generate several 2D cranio-caudal (CC) projections obtained during an acquisition of a standard DBT examination. Moreover, glandular absorbed doses and photon flux calculations, for each projection image, were performed. A homogeneous breast computational phantom with 50%/50% glandular/adipose tissue composition was used and two compressed breast thicknesses were evaluated: 4 cm and 8 cm. The simulated projection images were afterwards reconstructed with an algebraic reconstruction tool and the signal difference to noise ratio (SDNR) was calculated in order to evaluate the image quality in DBT and DM. Finally, a thorough comparison between the results obtained in terms of SDNR and dose assessment in DBT and DM was performed. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 50 条
  • [31] Evaluation of denoising digital breast tomosynthesis data in both projection and image domains and a study of noise model on digital breast tomosynthesis image domain
    Scarparo, Daniele Cristina
    Pinheiro Salvadeo, Denis Henrique
    Guimaraes Pedronette, Daniel Carlos
    Barufaldi, Bruno
    Arnold Maidment, Andrew Douglas
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [32] Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics
    King, J. M.
    Hickling, S.
    Elbakri, I. A.
    Reed, M.
    Wrogemann, J.
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [33] Optimization of exposure parameters in digital tomosynthesis considering effective dose and image quality
    Choi, Seungyeon
    Choi, Sunghoon
    Kim, Ye-seul
    Lee, Haenghwa
    Lee, Donghoon
    Jeon, Pil-Hyun
    Jang, Dong-Hyuk
    Kim, Hee-Joung
    [J]. MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [34] Medical Imaging Image Quality Assessment with Monte Carlo Methods
    Michail, C. M.
    Karpetas, G. E.
    Fountos, G. P.
    Kalyvas, N. I.
    Martini, Niki
    Koukou, Vaia
    Valais, I. G.
    Kandarakis, I. S.
    [J]. 4TH INTERNATIONAL CONFERENCE ON MATHEMATICAL MODELING IN PHYSICAL SCIENCES (IC-MSQUARE2015), 2015, 633
  • [35] PATIENT DOSE EVALUATION IN DIGITAL BREAST TOMOSYNTHESIS
    Kisielewicz, K.
    Rawojc, K.
    Dziubinska, A.
    Mazur, L.
    Kieltyka, B.
    Najberg-Pierzchala, D.
    Gadek, M.
    Luczynska, E.
    Wos, Z.
    Heinze, S.
    Dziecichowicz, A.
    [J]. ACTA PHYSICA POLONICA B, 2020, 51 (01): : 345 - 349
  • [36] Image quality measurements in breast tomosynthesis
    van Engen, Ruben
    Bouwman, Ramona
    van der Burght, Roeland
    Lazzari, Barbara
    Dance, David R.
    Heid, Patrice
    Aslund, Magnus
    Young, Kenneth C.
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 696 - +
  • [37] Simulation of Dose Reduction in Digital Breast Tomosynthesis
    Borges, Lucas R.
    Guerrero, Igor
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    Schiabel, Homero
    Vieira, Marcelo A. C.
    [J]. BREAST IMAGING, IWDM 2016, 2016, 9699 : 343 - 350
  • [38] Image Quality Evaluation of Breast Tomosynthesis
    Andria, G.
    Attivissimo, F.
    Di Nisio, A.
    Lanzoa, A. M. L.
    Spadavecchia, M.
    [J]. 2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2016, : 143 - 148
  • [39] Lesion assessment and radiation dose in Contrast-Enhanced Digital Breast Tomosynthesis
    Huang, Hailiang
    Scaduto, David A.
    Liu, Chunling
    Yang, Jie
    Zhu, Chencan
    Rinaldi, Kim
    Eisenberg, Jason
    Liu, Jingxuan
    Hoernig, Mathias
    Wicklein, Julia
    Vogt, Sebastian
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    [J]. 14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [40] Restored low-dose digital breast tomosynthesis: A perception study
    Borges, Lucas R.
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    Vieira, Marcelo A. C.
    [J]. MEDICAL IMAGING 2018: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2018, 10577