Influence of Implant Dimensions in the Resorbed and Bone Augmented Mandible: A Finite Element Study

被引:4
|
作者
Agop Forna, Doriana [1 ]
Forna, Norina Consuela [2 ]
Butnaru Moldoveanu, Sinziana Anca [3 ]
机构
[1] Univ Med & Pharm Grigore T Popa, Dept Dentoalveolar & Maxillofacial Surg, Fac Dent Med, Iasi, Romania
[2] Univ Med & Pharm Grigore T Popa, Dept Implantol, Removable Dentures, Dentures Technol,Fac Dent Med, Iasi, Romania
[3] Univ Med & Pharm Grigore T Popa, Fac Med Bioengn, Dept Biomed Sci, 9-16 M Kogalniceanu St, Iasi 700454, Romania
关键词
Bone augmentation; bone resorption; finite element analysis; implant dimensions; peri-implant stress; STRESS-DISTRIBUTION; DENTAL IMPLANTS; FOLLOW-UP; DIAMETER; LENGTH; PARAMETERS; PROSTHESES;
D O I
10.4103/ccd.ccd_366_19
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims: The scope of this study was to analyze the influence of clinically feasible implant diameter and length on the stress transmitted to the peri-implant bone in the case of a resorbed and bone augmented mandible through finite element analysis. Settings and Design: The study was carried out in silico. Subjects and Methods: Resorbed and bone-augmented 3D models were derived from in vivo cone-beam computed tomography scans of the same patient. Corresponding implant systems were modeled with the diameter ranging from 3.3 to 6 mm and length ranging from 5 to 13 mm, and masticatory loads were applied on the abutment surface. Statistical Analysis Used: None. Results: In the bone augmented ridge, maximum stress values in the peri-implant region drastically decreased only when using implants of a diameter of 5 mm and 6 mm. Implants up to 4 mm in diameter led to comparable stress values with the ones obtained in the resorbed ridge, when using the larger implants. The increase of length reduced stress in the resorbed mandible, whereas in the bone augmented model, it led to small variations only in implants up to 4 mm in diameter. Conclusions: It was concluded that bone augmentation provides the optimal framework for clinicians to use larger implants, which, in turn, reduces stress in the peri-implant region. Diameter and length play an equally important role in decreasing stress. Implant dimensions should be carefully considered with ridge geometry.
引用
收藏
页码:336 / 341
页数:6
相关论文
共 50 条
  • [31] Influence of Implant Tilting and Length on the Biomechanics of Single-Tooth Restoration: A Finite Element Analysis in Atrophic Mandible
    Anitua, Eduardo
    Saez de Ibarra, Naiara Larrazabal
    Morales Martin, Inigo
    Saracho Rotaeche, Luis
    DENTISTRY JOURNAL, 2022, 10 (05)
  • [32] Biomechanics study of dental implant-bone system by finite element method
    Roatesi, Iulia
    Roatesi, Simona
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (06)
  • [33] A SENSITIVITY STUDY BY FINITE ELEMENT ANALYSIS FOR THE ABUTMENT-IMPLANT-BONE SYSTEM
    Muraev, A. A.
    Tatoyan, A. D.
    Dolgalev, A. A.
    Vershinin, A. V.
    Yakovlev, M. Ya.
    Ivanov, S. Yu
    Konovalov, D. A.
    Petrovsky, K. A.
    Levin, V. A.
    MATHEMATICS AND MECHANICS OF COMPLEX SYSTEMS, 2022, 10 (01) : 1 - 20
  • [34] Finite element analysis of post dental implant fixation in drilled mandible sites
    Pirjamalineisiani, Adel
    Sarafbidabad, Mohsen
    Jamshidi, Nima
    Esfahani, Fatemeh Abedi
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 81 : 159 - 166
  • [35] Biomechanics study of dental implant-bone system by finite element method
    Iulia Roatesi
    Simona Roatesi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [36] Failure location prediction by finite element analysis for an additive manufactured mandible implant
    Huo, Jinxing
    Derand, Per
    Rannar, Lars-Erik
    Hirsch, Jan-Michael
    Gamstedt, E. Kristofer
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (09) : 862 - 869
  • [37] Biomechanical influence of plate configurations on mandible subcondylar fracture fixation: a finite element study
    Gupta, Anoushka
    Dutta, Abir
    Dutta, Kaushik
    Mukherjee, Kaushik
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (10) : 2581 - 2591
  • [38] Biomechanical influence of plate configurations on mandible subcondylar fracture fixation: a finite element study
    Anoushka Gupta
    Abir Dutta
    Kaushik Dutta
    Kaushik Mukherjee
    Medical & Biological Engineering & Computing, 2023, 61 : 2581 - 2591
  • [39] A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible
    Gialain, Ivan Onone
    Gantier-Takano, Marlene Kasumi
    da Silva, Leonardo Folmer Rodrigues
    Roscoe, Marina Guimaraes
    Pinhata-Baptista, Otavio Henrique
    Meira, Josete Barbosa Cruz
    Fok, Alex Siu Lun
    JOURNAL OF PROSTHODONTIC RESEARCH, 2025, 69 (01) : 110 - 119
  • [40] Influence of sidewall retention and interference fit in total ankle replacement on implant-bone micromotion: A finite element study
    Johnson, Joshua E.
    Clarke, Gabriel A.
    de Cesar Netto, Cesar
    Anderson, Donald D.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (07) : 1536 - 1544