A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible

被引:0
|
作者
Gialain, Ivan Onone [1 ,2 ]
Gantier-Takano, Marlene Kasumi [1 ]
da Silva, Leonardo Folmer Rodrigues [1 ]
Roscoe, Marina Guimaraes [1 ]
Pinhata-Baptista, Otavio Henrique [3 ,4 ]
Meira, Josete Barbosa Cruz [1 ]
Fok, Alex Siu Lun [5 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biol, Av Prof Lineu Prestes,2227, BR-05508000 Sao Paulo, Brazil
[2] Univ Cuiaba, Cuiaba, Brazil
[3] Univ Sao Paulo, Mil Hosp Sao Paulo Area, Dent Div, Sao Paulo, Brazil
[4] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, Brazil
[5] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN USA
关键词
Mandible; Bone resorption; Dental implant; Dental prostheses; Occlusal load; ITI CONSENSUS REPORT; STRESS-DISTRIBUTION; SURROUNDING BONE; VALIDATION; DIAMETER; QUALITY; DESIGN; CROWNS; LENGTH;
D O I
10.2186/jpr.JPR_D_24_00003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible. Methods: Implants of different lengths (L = 4 or 6 mm) and diameters (0 = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 mu J/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold. Results: Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the 04.1 short implant with 3ca had a medium (0.8 <= PIBRri <= 1.0) or high (PIBRri>1.0) resorption risk. Conclusions: Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [1] Evaluation of Bone Turnover around Short Finned Implants in Atrophic Posterior Maxilla: A Finite Element Study
    Kondratiev, Andrii
    Demenko, Vladislav
    Linetskiy, Igor
    Weisskircher, Hans-Werner
    Linetska, Larysa
    PROSTHESIS, 2024, 6 (05): : 1170 - 1188
  • [2] Bone quality effect on short implants in the edentulous mandible: a finite element study
    Chaowei Liu
    Yifeng Xing
    Yan Li
    Yanjun Lin
    Jianghan Xu
    Dong Wu
    BMC Oral Health, 22
  • [3] Bone quality effect on short implants in the edentulous mandible: a finite element study
    Liu, Chaowei
    Xing, Yifeng
    Li, Yan
    Lin, Yanjun
    Xu, Jianghan
    Wu, Dong
    BMC ORAL HEALTH, 2022, 22 (01)
  • [4] Comparative Finite Element Analysis of Short Implants with Different Treatment Approaches in the Atrophic Mandible
    Doganay, Ozge
    Kilic, Erdem
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (04) : E69 - E76
  • [5] Finite element analysis of bone loss around failing implants
    Wolff, Jan
    Narra, Nathaniel
    Antalainen, Anna-Kaisa
    Valasek, Jiri
    Kaiser, Jozef
    Sandor, George K.
    Marcian, Petr
    MATERIALS & DESIGN, 2014, 61 : 177 - 184
  • [6] Rehabilitation of the atrophic mandible with short implants in different positions: A finite elements study
    Peixoto, Hugo E.
    Camati, Paulo R.
    Faot, Fernanda
    Sotto-Maior, Bruno S.
    Martinez, Elizabeth F.
    Peruzzo, Daiane C.
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 80 : 122 - 128
  • [7] Finite-element study of biomechanical explanations for bone loss around dental implants
    Merdji A.
    Taharou B.
    Hillstrom R.
    Benaissa A.
    Roy S.
    Chong P.L.
    Mukdadi O.
    Della N.
    Bouiadjra B.-A.B.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (01) : 21 - 30
  • [8] Does increasing the number of short implants reduce marginal bone loss in the posterior mandible? A prospective study
    Tabrizi, Reza
    Arabion, Hamidreza
    Aliabadi, Ehsan
    Hasanzadeh, Farzaneh
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (07): : 731 - 735
  • [9] Comparison of Stress and Strain Distribution Around Splinted and Nonsplinted 6-mm Short Implants in Posterior Mandible: A Finite Element Analysis Study
    Meimandi, Mansour
    Ardakani, Mohammad Reza Talebi
    Amid, Reza
    Motlagh, Amir Mahmoudi
    Beheshti, Shahrzad
    IMPLANT DENTISTRY, 2018, 27 (01) : 74 - 80
  • [10] The proportion of cancellous bone as predictive factor for early marginal bone loss around implants in the posterior part of the mandible
    Simons, Willem-Frederik
    De Smit, Menke
    Duyck, Joke
    Coucke, Wim
    Quirynen, Marc
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1051 - 1059