A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible

被引:0
|
作者
Gialain, Ivan Onone [1 ,2 ]
Gantier-Takano, Marlene Kasumi [1 ]
da Silva, Leonardo Folmer Rodrigues [1 ]
Roscoe, Marina Guimaraes [1 ]
Pinhata-Baptista, Otavio Henrique [3 ,4 ]
Meira, Josete Barbosa Cruz [1 ]
Fok, Alex Siu Lun [5 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biol, Av Prof Lineu Prestes,2227, BR-05508000 Sao Paulo, Brazil
[2] Univ Cuiaba, Cuiaba, Brazil
[3] Univ Sao Paulo, Mil Hosp Sao Paulo Area, Dent Div, Sao Paulo, Brazil
[4] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, Brazil
[5] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN USA
关键词
Mandible; Bone resorption; Dental implant; Dental prostheses; Occlusal load; ITI CONSENSUS REPORT; STRESS-DISTRIBUTION; SURROUNDING BONE; VALIDATION; DIAMETER; QUALITY; DESIGN; CROWNS; LENGTH;
D O I
10.2186/jpr.JPR_D_24_00003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible. Methods: Implants of different lengths (L = 4 or 6 mm) and diameters (0 = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 mu J/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold. Results: Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the 04.1 short implant with 3ca had a medium (0.8 <= PIBRri <= 1.0) or high (PIBRri>1.0) resorption risk. Conclusions: Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [31] Peri-implant bone loss around posterior mandible dental implants placed after distraction osteogenesis: Preliminary findings
    Polo, Wilson C. K.
    de Araujo, Ney Soares
    Lima, Ynara B. O.
    Joly, Julio Cesar
    Sendyk, Wilson R.
    Cury, Patricia R.
    JOURNAL OF PERIODONTOLOGY, 2007, 78 (02) : 204 - 208
  • [32] Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible
    Draenert, Florian G.
    Sagheb, Keyvan
    Baumgardt, Katharina
    Kaemmerer, Peer W.
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (09) : 1063 - 1069
  • [33] Rehabilitation of Atrophic Posterior Maxilla with Pterygoid Implants: A 3D Finite Element Analysis
    Wilkirson, Elizabeth
    Chandran, Ravi
    Duan, Yuanyuan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : E51 - E62
  • [34] Does Bruxism Affect Marginal Bone Level around Single Tooth Implants in the Posterior Mandible?
    Tabrizi, Reza
    Rasaei, Mahdie
    Moslemi, Hamidreza
    Shafiei, Shervin
    Latifi, Fatemeh
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2022, 21 (04): : 1162 - 1167
  • [35] Does Bruxism Affect Marginal Bone Level around Single Tooth Implants in the Posterior Mandible?
    Reza Tabrizi
    Mahdie Rasaei
    Hamidreza Moslemi
    Shervin Shafiei
    Fatemeh Latifi
    Journal of Maxillofacial and Oral Surgery, 2022, 21 : 1162 - 1167
  • [36] Load-carrying capacity of short implants in edentulous posterior maxilla: A finite element study
    Demenko, Vladislav
    Linetskiy, Igor
    Linetska, Larysa
    Yefremov, Oleg
    MEDICAL ENGINEERING & PHYSICS, 2019, 71 : 30 - 37
  • [37] Virtual Bone Augmentation in Atrophic Mandible to Assess Optimal Implant-Prosthetic Rehabilitation-A Finite Element Study
    Butnaru-Moldoveanu, Sinziana Anca
    Munteanu, Florin
    Forna, Norina Consuela
    APPLIED SCIENCES-BASEL, 2020, 10 (01):
  • [38] Evaluating the Feasibility of Short Dental Implants as Alternatives to Long Dental Implants in Mandibular Bone: A Finite Element Study
    Deshmukh, Prathamesh
    Dhatrak, Pankaj
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2024, 112 (09)
  • [39] The Effect of the Length and Distribution of Implants for Fixed Prosthetic Reconstructions in the Atrophic Posterior Maxilla: A Finite Element Analysis
    Cenkoglu, Brunilda Gashi
    Balcioglu, Nilufer Bolukbasi
    Ozdemir, Tayfun
    Mijiritsky, Eitan
    MATERIALS, 2019, 12 (16)
  • [40] Finite element simulation of bone remodelling in human mandible around osseointegrated dental implant
    Lian, Z. Q.
    Guan, H.
    Loo, Y. C.
    Ivanovski, S.
    Johnson, N. W.
    9TH WORLD CONGRESS ON COMPUTATIONAL MECHANICS AND 4TH ASIAN PACIFIC CONGRESS ON COMPUTATIONAL MECHANICS, 2010, 10