Assessing the carbon sequestration potential of basalt using X-ray micro-CT and rock mechanics

被引:69
|
作者
Callow, Ben [1 ]
Falcon-Suarez, Ismael [2 ]
Ahmed, Sharif [3 ]
Matter, Juerg [1 ]
机构
[1] Univ Southampton, Ocean & Earth Sci, Southampton SO14 3ZH, Hants, England
[2] Univ Southampton, Natl Oceanog Ctr, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
[3] Univ Southampton, Fac Engn & Environm, VIS Xray Imaging Ctr, Univ Rd, Southampton SO17 1BJ, Hants, England
关键词
CO2; sequestration; Geological storage; Basalt; Permeability; X-ray micro-CT; Image-based modelling; MINERAL SEQUESTRATION; CO2; SEQUESTRATION; GEOTHERMAL-FIELD; ICELAND; STORAGE; PERMEABILITY; TRANSPORT; HELLISHEIDI; SENSITIVITY; CHEMISTRY;
D O I
10.1016/j.ijggc.2017.12.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mineral carbonation in basaltic rock provides a permanent storage solution for the mitigation of anthropogenic CO2 emissions in the atmosphere. 3D X-ray micro-CT (XCT) image analysis is applied to a core sample from the main basaltic reservoir of the CarbFix site in Iceland, which obtained a connected porosity of 2.05-8.76%, a reactive surface area of 0.10-0.33 mm(-1) and a larger vertical permeability (2.07 x 10(-10) m(2)) compared to horizontal permeability (5.10 x 10(-11) m(2)). The calculations suggest a CO2 storage capacity of 0.33 Gigatonnes at the CarbFix pilot site. The XCT results were compared to those obtained from a hydromechanical test applied to the same sample, during which permeability, electrical resistivity and volumetric deformation were measured under realistic reservoir pressure conditions. It was found that permeability is highly stress sensitive, dropping by two orders of magnitude for a -0.02% volumetric deformation change, equivalent to a mean pore diameter reduction of 5 mu m. This pore contraction was insufficient to explain such a permeability reduction according to the XCT analysis, unless combined with the effects of clay swelling and secondary mineral pore clogging. The findings provide important benchmark data for the future upscaling and optimisation of CO2 storage in basalt formations.
引用
收藏
页码:146 / 156
页数:11
相关论文
共 50 条
  • [31] Resolution and Limitations of X-Ray Micro-CT with Applications to Sandstones and Limestones
    Jean E. Elkhoury
    Raji Shankar
    T. S. Ramakrishnan
    Transport in Porous Media, 2019, 129 : 413 - 425
  • [32] Investigation of Sparse Data Mouse Imaging Using Micro-CT with a Carbon-Nanotube-Based X-ray Source
    SIDKY Emil Y
    ZHOU Otto
    Tsinghua Science and Technology, 2010, 15 (01) : 74 - 78
  • [33] X-ray micro-CT study of Cabeco de Vide serpentinites and carbonate rock samples: a preliminary approach
    Mauricio, A.
    Pereira, M. F.
    Rocha, C.
    Figueiredo, C.
    Marques, J. M.
    15TH WATER-ROCK INTERACTION INTERNATIONAL SYMPOSIUM, WRI-15, 2017, 17 : 952 - 955
  • [34] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [35] Using X-ray micro-CT imaging to monitor dissolution of macroporous bioactive glass scaffolds
    Jones, JR
    Milroy, GE
    Cameron, RE
    Bonfield, W
    Hench, LL
    BIOCERAMICS 17, 2005, 284-286 : 493 - 496
  • [36] Three-dimensional reconstruction of neurons in the brain by using X-ray micro-CT technology
    Mizutani, Haruo
    Takeda, Yoshihiro
    Momose, Atsushi
    Takagi, Toshihisa
    NEUROSCIENCE RESEARCH, 2007, 58 : S184 - S184
  • [37] Data-Constrained Microstructure Characterization with Multispectrum X-Ray Micro-CT
    Mayo, Sheridan C.
    Tulloh, Andrew M.
    Trinchi, Adrian
    Yang, Sam Y. S.
    MICROSCOPY AND MICROANALYSIS, 2012, 18 (03) : 524 - 530
  • [38] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [39] X-ray micro-CT measurement of large parts at very low temperature
    Koutecky, T.
    Zikmund, T.
    Glittova, D.
    Palousek, D.
    Zivcak, J.
    Kaiser, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [40] X-ray micro-CT applied to natural building materials and art objects
    De Witte, Y.
    Cnudde, V.
    Pieters, K.
    Masschaele, B.
    Dierick, M.
    Vlassenbroeck, J.
    Van Hoorebeke, L.
    Jacobs, P.
    X-RAY SPECTROMETRY, 2008, 37 (04) : 383 - 387