Assessing the carbon sequestration potential of basalt using X-ray micro-CT and rock mechanics

被引:69
|
作者
Callow, Ben [1 ]
Falcon-Suarez, Ismael [2 ]
Ahmed, Sharif [3 ]
Matter, Juerg [1 ]
机构
[1] Univ Southampton, Ocean & Earth Sci, Southampton SO14 3ZH, Hants, England
[2] Univ Southampton, Natl Oceanog Ctr, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
[3] Univ Southampton, Fac Engn & Environm, VIS Xray Imaging Ctr, Univ Rd, Southampton SO17 1BJ, Hants, England
关键词
CO2; sequestration; Geological storage; Basalt; Permeability; X-ray micro-CT; Image-based modelling; MINERAL SEQUESTRATION; CO2; SEQUESTRATION; GEOTHERMAL-FIELD; ICELAND; STORAGE; PERMEABILITY; TRANSPORT; HELLISHEIDI; SENSITIVITY; CHEMISTRY;
D O I
10.1016/j.ijggc.2017.12.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mineral carbonation in basaltic rock provides a permanent storage solution for the mitigation of anthropogenic CO2 emissions in the atmosphere. 3D X-ray micro-CT (XCT) image analysis is applied to a core sample from the main basaltic reservoir of the CarbFix site in Iceland, which obtained a connected porosity of 2.05-8.76%, a reactive surface area of 0.10-0.33 mm(-1) and a larger vertical permeability (2.07 x 10(-10) m(2)) compared to horizontal permeability (5.10 x 10(-11) m(2)). The calculations suggest a CO2 storage capacity of 0.33 Gigatonnes at the CarbFix pilot site. The XCT results were compared to those obtained from a hydromechanical test applied to the same sample, during which permeability, electrical resistivity and volumetric deformation were measured under realistic reservoir pressure conditions. It was found that permeability is highly stress sensitive, dropping by two orders of magnitude for a -0.02% volumetric deformation change, equivalent to a mean pore diameter reduction of 5 mu m. This pore contraction was insufficient to explain such a permeability reduction according to the XCT analysis, unless combined with the effects of clay swelling and secondary mineral pore clogging. The findings provide important benchmark data for the future upscaling and optimisation of CO2 storage in basalt formations.
引用
收藏
页码:146 / 156
页数:11
相关论文
共 50 条
  • [41] X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT
    Kim, Jae G.
    Park, So E.
    Lee, Soo Y.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 63 - 75
  • [42] Enhanced X-ray absorption for micro-CT analysis of low density polymers
    Crica, Livia Elena
    Wengenroth, Jonas
    Tiainen, Hanna
    Ionita, Mariana
    Haugen, Havard Jostein
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2016, 27 (09) : 805 - 823
  • [43] Statistical reconstruction for X-ray micro-CT systems with noncontinuous detectors.
    Zbijewski, Wojciech
    Beekman, Freek J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2323 - 2326
  • [44] A perfusion procedure for imaging of the mouse cerebral vasculature by X-ray micro-CT
    Ghanavati, Sahar
    Yu, Lisa X.
    Lerch, Jason P.
    Sled, John G.
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 221 : 70 - 77
  • [45] Automated Segmentation of Murine Lung Tumors in X-ray micro-CT Images
    Swee, Joshua K. Y.
    Sheridan, Clare
    de Bruin, Elza
    Downward, Julian
    Lassailly, Francois
    Pizarro, Luis
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [46] Micro X-ray CT at spring-8 for granular mechanics
    Matsushima, Takashi
    Katagiri, Jun
    Uesugi, Kentaro
    Nakano, Tsukasa
    Tsuchiyama, Akira
    SOIL STRESS-STAIN BEHAVIOR: MEASUREMENT, MODELING AND ANALYSIS, 2007, 146 : 225 - +
  • [47] Strength, deformability and X-ray micro-CT observations of transversely isotropic composite rock under different confining pressures
    Yang, Sheng-Qi
    Yin, Peng-Fei
    Huang, Yan-Hua
    Cheng, Jian-Long
    ENGINEERING FRACTURE MECHANICS, 2019, 214 : 1 - 20
  • [48] Micro-CTvlab : A web based virtual gallery of biological specimens using X-ray microtomography (micro-CT)
    Keklikoglou, Kleoniki
    Faulwetter, Sarah
    Chatzinikolaou, Eva
    Michalakis, Nikitas
    Filiopoulou, Irene
    Minadakis, Nikos
    Panteri, Emmanouela
    Perantinos, George
    Gougousis, Alexandros
    Arvanitidis, Christos
    BIODIVERSITY DATA JOURNAL, 2016, 4
  • [49] Methodological Refinements to Using Lugol's Iodine as a Contrast Agent in X-ray Micro-CT Imaging
    Gignac, P. M.
    Kley, N. J.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2013, 53 : E77 - E77
  • [50] Whole-Body Imaging of a Hypercholesterolemic Female Zebrafish by Using Synchrotron X-Ray Micro-CT
    Seo, Eunseok
    Lim, Jae-Hong
    Seo, Seung Jun
    Lee, Sang Joon
    ZEBRAFISH, 2015, 12 (01) : 11 - 20