Diagnostic performance of wrist magnetic resonance (MR) arthrography: comparison of three-dimensional isotropic T1 weighted fast spin-echo MR arthrography and two-dimensional MR arthrography

被引:5
|
作者
Oh, Eunsun [1 ]
Yoon, Young C. [1 ]
Park, Min J. [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Radiol, Samsung Med Ctr, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Orthoped Surg, Samsung Med Ctr, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2017年 / 90卷 / 1071期
关键词
3.0; T; TRIANGULAR FIBROCARTILAGE; STANDARD MRI; TFCC TEARS; TESLA; SHOULDER; KNEE; LIGAMENTS; ARTHROSCOPY; EXPERIENCE;
D O I
10.1259/bjr.20160867
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the diagnostic performance of direct wrist MR arthrography (D-MRA) with two-dimensional (2D) T-1 weighted fast spin-echo (FSE) and three-dimensional (3D) isotropic T-1 weighted FSE sequences for detecting triangular fibrocartilage (TFC) central perforations and scapholunate ligament (SLL) and lunotriquetral ligament (LTL) tears. Methods: 26 patients who had undergone pre-operative wrist D-MRA with 2D and 3D isotropic T-1 weighted FSE sequences and subsequent arthroscopic surgeries were included. Each MRI sequence was independently evaluated and scored by two readers retrospectively for the presence of TFC central perforations and SLL and LTL tears. Arthroscopic findings were used as the reference standard. Diagnostic performance was evaluated by using the area under the receiver operating characteristic curve. The sensitivity, specificity and accuracy of both sequences for diagnosing the injuries were calculated. Results: Arthroscopic surgery revealed 21 TFC central perforations, 7 SLL tears and 3 LTL tears. The area under the receiver operating characteristic curve value of 2D and 3D for central perforations in TFC and tears in SLL and LTL was identical or similar (0.667-0.947). The sensitivity, specificity and accuracy of both sequences for diagnosing the injury of each structure were not significantly different (TFC, 90.5/80/88.5% for both readers/sequences; SLL, 100/89.5/92.3% for both readers' 2D and Reader A's 3D, and 85.7/89.5/88.5% for Reader B's 3D; LTL, 66.7/100/96.2% for both readers' 2D and 33.3/100/92.3% for both readers' 3D). Interobserver agreements were substantial to excellent. Conclusion: In wrist D-MRA, the diagnostic performances of 3D isotropic and 2D T-1 weighted FSE sequences are comparable for TFC central perforations and SLL and LTL tears.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] MR cisternography of the cerebellopontine angle: Comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences
    Naganawa, S
    Koshikawa, T
    Fukatsu, H
    Ishigaki, T
    Fukuta, T
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (06) : 1179 - 1185
  • [32] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury
    Park, H. J.
    Lee, S. Y.
    Park, N. H.
    Rho, M. H.
    Chung, E. C.
    Park, J. H.
    Park, S. J.
    CLINICAL RADIOLOGY, 2016, 71 (04) : 349 - 355
  • [33] Liver T2-weighted MR imaging: Assessment of a three-dimensional fast spin-echo with extended echo train acquisition sequence at 1.5 Tesla
    Denoiseux, Celine Cotereau
    Boulay-Coletta, Isabelle
    Nakache, Jean-Pierre
    Claude, Isabelle Dufour
    Zins, Marc
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 336 - 343
  • [34] Three-dimensional static-fluid MR urography with gradient- and spin-echo (GRASE) at 3.0T: comparison of image quality and diagnostic performance with respiratory-triggered fast spin-echo (FSE)
    Wang, Wei
    Yang, Junzhe
    Liu, Jing
    Li, Wei
    Zhao, Kai
    Xue, Ke
    Dai, Yongming
    Qiu, Jianxing
    ABDOMINAL RADIOLOGY, 2022, 47 (05) : 1828 - 1839
  • [35] Magnetic resonance visualization of surgical classification of rotator cuff tear: comparison with three-dimensional shoulder magnetic resonance arthrography at 3.0 T
    Lee, Young Han
    Kim, Ah Hyun
    Suh, Jin-Suck
    CLINICAL IMAGING, 2014, 38 (06) : 858 - 863
  • [36] Three-dimensional static-fluid MR urography with gradient- and spin-echo (GRASE) at 3.0T: comparison of image quality and diagnostic performance with respiratory-triggered fast spin-echo (FSE)
    Wei Wang
    Junzhe Yang
    Jing Liu
    Wei Li
    Kai Zhao
    Ke Xue
    Yongming Dai
    Jianxing Qiu
    Abdominal Radiology, 2022, 47 : 1828 - 1839
  • [37] Comparison of three-dimensional isotropic and conventional MR arthrography with respect to the diagnosis of rotator cuff and labral lesions: Focus on isotropic fat-suppressed proton density and VIBE sequences
    Park, S. Y.
    Lee, I. S.
    Park, S. K.
    Cheon, S. J.
    Ahn, J. M.
    Song, J. W.
    CLINICAL RADIOLOGY, 2014, 69 (04) : E173 - E182
  • [38] Optimized single-slab three-dimensional spin-echo MR imaging of the brain
    Mugler, JP
    Bao, SM
    Mulkern, RV
    Guttmann, CRG
    Robertson, RL
    Jolesz, FA
    Brookeman, JR
    RADIOLOGY, 2000, 216 (03) : 891 - 899
  • [39] Magnetic Resonance Imaging of Ankle Syndesmotic Ligament Injuries: Comparison of Three-dimensional Isotropic Intermediate-weighted Fast Spin Echo with Conventional Two-dimensional Imaging
    Park, J. W.
    Lee, S. J.
    Choo, H. J.
    Gwak, H. C.
    Park, D. H.
    Kim, M. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2020, 23 (03): : 391 - 397
  • [40] Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences
    Park, Hee Jin
    Lee, So Yeon
    Park, Noh Hyuck
    Ahn, Jin Hwan
    Chung, Eun Chul
    Kim, Sung Jun
    Cha, Jang Gyu
    ACTA RADIOLOGICA, 2016, 57 (11) : 1372 - 1379