Diagnostic performance of wrist magnetic resonance (MR) arthrography: comparison of three-dimensional isotropic T1 weighted fast spin-echo MR arthrography and two-dimensional MR arthrography

被引:5
|
作者
Oh, Eunsun [1 ]
Yoon, Young C. [1 ]
Park, Min J. [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Radiol, Samsung Med Ctr, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Orthoped Surg, Samsung Med Ctr, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2017年 / 90卷 / 1071期
关键词
3.0; T; TRIANGULAR FIBROCARTILAGE; STANDARD MRI; TFCC TEARS; TESLA; SHOULDER; KNEE; LIGAMENTS; ARTHROSCOPY; EXPERIENCE;
D O I
10.1259/bjr.20160867
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the diagnostic performance of direct wrist MR arthrography (D-MRA) with two-dimensional (2D) T-1 weighted fast spin-echo (FSE) and three-dimensional (3D) isotropic T-1 weighted FSE sequences for detecting triangular fibrocartilage (TFC) central perforations and scapholunate ligament (SLL) and lunotriquetral ligament (LTL) tears. Methods: 26 patients who had undergone pre-operative wrist D-MRA with 2D and 3D isotropic T-1 weighted FSE sequences and subsequent arthroscopic surgeries were included. Each MRI sequence was independently evaluated and scored by two readers retrospectively for the presence of TFC central perforations and SLL and LTL tears. Arthroscopic findings were used as the reference standard. Diagnostic performance was evaluated by using the area under the receiver operating characteristic curve. The sensitivity, specificity and accuracy of both sequences for diagnosing the injuries were calculated. Results: Arthroscopic surgery revealed 21 TFC central perforations, 7 SLL tears and 3 LTL tears. The area under the receiver operating characteristic curve value of 2D and 3D for central perforations in TFC and tears in SLL and LTL was identical or similar (0.667-0.947). The sensitivity, specificity and accuracy of both sequences for diagnosing the injury of each structure were not significantly different (TFC, 90.5/80/88.5% for both readers/sequences; SLL, 100/89.5/92.3% for both readers' 2D and Reader A's 3D, and 85.7/89.5/88.5% for Reader B's 3D; LTL, 66.7/100/96.2% for both readers' 2D and 33.3/100/92.3% for both readers' 3D). Interobserver agreements were substantial to excellent. Conclusion: In wrist D-MRA, the diagnostic performances of 3D isotropic and 2D T-1 weighted FSE sequences are comparable for TFC central perforations and SLL and LTL tears.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The usefulness of the three-dimensional enhanced T1 high-resolution isotropic volume excitation MR in the evaluation of shoulder pathology: comparison with two-dimensional enhanced T1 fat saturation MR
    Park, Hee J.
    Lee, So Y.
    Rho, Myung H.
    Kwon, Heon J.
    Kim, Mi S.
    Chung, Eun C.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1054):
  • [22] Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist
    Park, Hee Jin
    Lee, So Yeon
    Kang, Kyung A.
    Kim, Eun Young
    Shin, Hun Kyu
    Park, Se Jin
    Park, Jai Hyung
    Kim, Eugene
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084):
  • [23] Single-slab three-dimensional T2-weighted fast spin-echo MR imaging of multiple sclerosis patients
    Zhao, L
    Mugler, JP
    Li, X
    Wei, X
    Mulkern, V
    Guttmann, CR
    RADIOLOGY, 2001, 221 : 140 - 140
  • [24] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [25] MR IMAGING OF THE KNEE - COMPARISON OF 3-DIMENSIONAL FISP AND TWO-DIMENSIONAL SPIN-ECHO PULSE SEQUENCES
    SOLOMON, SL
    TOTTY, WG
    LEE, JKT
    RADIOLOGY, 1989, 173 (03) : 739 - 742
  • [26] Noncontrast MR imaging and MR arthrography of the ulnar collateral ligament of the elbow: prospective evaluation of two-dimensional pulse sequences for detection of complete tears
    Carrino, JA
    Morrison, WB
    Zou, KH
    Steffen, RT
    Snearly, WN
    Murray, PM
    SKELETAL RADIOLOGY, 2001, 30 (11) : 625 - 632
  • [27] Noncontrast MR imaging and MR arthrography of the ulnar collateral ligament of the elbow: prospective evaluation of two-dimensional pulse sequences for detection of complete tears
    John A. Carrino
    William B. Morrison
    Kelly H. Zou
    Richard T. Steffen
    William N. Snearly
    Peter M. Murray
    Skeletal Radiology, 2001, 30 : 625 - 632
  • [28] Use of a three-dimensional fast spin-echo MR imaging sequence in the evaluation of the cruciate ligaments of the knee
    Sonin, AH
    Penrod, BJ
    McRae, GA
    RADIOLOGY, 1997, 205 : 1490 - 1490
  • [29] Spatial relationship between vestibular schwannoma and facial nerve on three-dimensional T2-weighted fast spin-echo MR images
    Sartoretti-Schefer, S
    Kollias, S
    Valavanis, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (05) : 810 - 816
  • [30] Three-dimensional fast-recovery fast spin-echo MRCP: Comparison with two-dimensional single-shot fast spin-echo techniques
    Sodickson, A
    Mortele, KJ
    Barish, MA
    Zou, KH
    Thibodeau, S
    Tempany, CMC
    RADIOLOGY, 2006, 238 (02) : 549 - 559