Long open-path measurements of greenhouse gases in air using near-infrared Fourier transform spectroscopy

被引:24
|
作者
Griffith, David W. T. [1 ]
Poehler, Denis [2 ]
Schmitt, Stefan [2 ]
Hammer, Samuel [2 ]
Vardag, Sanam N. [2 ,3 ]
Platt, Ulrich [2 ]
机构
[1] Univ Wollongong, Ctr Atmospher Chem, Wollongong, NSW, Australia
[2] Heidelberg Univ, Inst Environm Phys, Heidelberg, Germany
[3] Heidelberg Univ, Heidelberg Ctr Environm, Heidelberg, Germany
关键词
INSTRUMENTAL LINE-SHAPE; TRACE-GAS; METHANE EMISSIONS; CO2; SPECTROMETERS; CALIBRATION; NETWORK; FTIR; POLLUTANTS; ACCURACY;
D O I
10.5194/amt-11-1549-2018
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
In complex and urban environments, atmospheric trace gas composition is highly variable in time and space. Point measurement techniques for trace gases with in situ instruments are well established and accurate, but do not provide spatial averaging to compare against developing high-resolution atmospheric models of composition and meteorology with resolutions of the order of a kilometre. Open-path measurement techniques provide path average concentrations and spatial averaging which, if sufficiently accurate, may be better suited to assessment and interpretation with such models. Open-path Fourier transform spectroscopy (FTS) in the mid-infrared region, and differential optical absorption spectroscopy (DOAS) in the UV and visible, have been used for many years for open-path spectroscopic measurements of selected species in both clean air and in polluted environments. Near infrared instrumentation allows measurements over longer paths than mid-infrared FTS for species such as greenhouse gases which are not easily accessible to DOAS. In this pilot study we present the first open-path near-infrared (4000-10 000 cm(-1), 1.0-2.5 mu m) FTS measurements of CO2, CH4, O-2, H2O and HDO over a 1.5 km path in urban Heidelberg, Germany. We describe the construction of the open-path FTS system, the analysis of the collected spectra, several measures of precision and accuracy of the measurements, and the results a four-month trial measurement period in July-November 2014. The open-path measurements are compared to calibrated in situ measurements made at one end of the open path. We observe significant differences of the order of a few ppm for CO2 and a few tens of ppb for CH4 between the open-path and point measurements which are 2 to 4 times the measurement repeatability, but we cannot unequivocally assign the differences to specific local sources or sinks. We conclude that open-path FTS may provide a valuable new tool for investigations of atmospheric trace gas composition in complex, small-scale environments such as cities.
引用
收藏
页码:1549 / 1563
页数:15
相关论文
共 50 条
  • [21] A single-beam titration method for the quantification of open-path Fourier transform infrared spectroscopy
    Sung, Lung-Yu
    Lu, Chia-Jung
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2014, 145 : 43 - 49
  • [22] An evaluation of flare combustion efficiency using open-path Fourier transform infrared technology
    Blackwood, TR
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (10): : 1714 - 1722
  • [23] Open-path Fourier transform infrared spectrometry characterization of low temperature combustion gases in biomass fuels
    de Castro, A. J.
    Lerma, A. M.
    Lopez, F.
    Guijarro, M.
    Diez, C.
    Hernando, C.
    Madrigal, J.
    INFRARED PHYSICS & TECHNOLOGY, 2007, 51 (01) : 21 - 30
  • [24] Ground-Based Remote Sensing with Open-Path Fourier-Transform Infrared (OP-FTIR) Spectroscopy for Large-Scale Monitoring of Greenhouse Gases
    Schuetze, C.
    Lau, S.
    Reiche, N.
    Sauer, U.
    Borsdorf, H.
    Dietrich, P.
    GHGT-11, 2013, 37 : 4276 - 4282
  • [25] Evaluation of flare combustion efficiency using open-path Fourier transform infrared technology
    Blackwood, Thomas R.
    Journal of the Air and Waste Management Association, 2000, 50 (10): : 1714 - 1722
  • [26] Visible and near-infrared Fourier transform spectroscopy with a common-path interferometer
    Perri, Antonio
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2021, 54 (11)
  • [27] Monitoring of CO flare emissions using open-path Fourier transform infrared technology
    Zwicker, JO
    Ringler, E
    Kagann, R
    ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES, 1999, 3534 : 9 - 20
  • [28] Application of open-path Fourier transform infrared spectroscopy (OP-FTIR) to measure greenhouse gas concentrations from agricultural fields
    Lin, Cheng-Hsien
    Grant, Richard H.
    Heber, Albert J.
    Johnston, Cliff T.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (06) : 3403 - 3415
  • [29] Monitoring of Grape Decay via Its Volatiles Based on Open-Path Fourier Transform Infrared Spectroscopy
    Wang Jie-jun
    Chen Jia
    Ye Song
    Dong Da-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (07) : 2132 - 2135
  • [30] Applications of Fourier transform infrared spectroscopy, Fourier transform infrared microscopy and near-infrared spectroscopy to cancer research
    Yano, K
    Sakamoto, Y
    Hirosawa, N
    Tonooka, S
    Katayama, H
    Kumaido, K
    Satomi, A
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2003, 17 (2-3): : 315 - 321