An evaluation of flare combustion efficiency using open-path Fourier transform infrared technology

被引:12
|
作者
Blackwood, TR [1 ]
机构
[1] Healthsite Associates, Ballwin, MO USA
来源
关键词
D O I
10.1080/10473289.2000.10464206
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Open-path Fourier transform infrared (OP-FTIR) technology was used to evaluate the combustion efficiency of a flare for comparison to several combustion models. Most flares have been considered an effective method for destroying organic compounds and anything that burns. As the Btu content of the flare gas is reduced, the combustion efficiency may also be reduced. Recent studies have suggested that lower Btu flares may have efficiencies as low as 65%. In addition, models have been developed to predict the effect of wind speed and stack discharge velocity on the combustion efficiency. This study was conducted on a low-Btu flare gas that is primarily CO. While the models would predict efficiencies as low as 30%, the sampling using OP-FTIR showed most combustion efficiencies well above 90%. Three methods were used to track combustion efficiency: monitoring the ratio of CO to CO2, monitoring the ratio of CO to tracer gas, and dispersion modeling. This study was complicated by the presence of two flare stacks, thus two tracer gases were used-SF6 and CF4. A method was developed for distinguishing between the two stacks and quantifying the efficiency in each stack.
引用
收藏
页码:1714 / 1722
页数:9
相关论文
共 50 条
  • [1] Evaluation of flare combustion efficiency using open-path Fourier transform infrared technology
    Blackwood, Thomas R.
    Journal of the Air and Waste Management Association, 2000, 50 (10): : 1714 - 1722
  • [2] Monitoring of CO flare emissions using open-path Fourier transform infrared technology
    Zwicker, JO
    Ringler, E
    Kagann, R
    ENVIRONMENTAL MONITORING AND REMEDIATION TECHNOLOGIES, 1999, 3534 : 9 - 20
  • [3] Open-path Fourier transform infrared spectroscopy
    Tucker, MD
    Shaffer, RE
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1999, 3 (02): : 67 - 68
  • [4] Axicon as a retroreflector in open-path Fourier transform infrared spectrometry
    Richardson, RL
    Griffiths, PR
    OPTICAL ENGINEERING, 2003, 42 (08) : 2197 - 2201
  • [5] Emissions from smoldering combustion of biomass measured by open-path Fourier transform infrared spectroscopy
    Yokelson, RJ
    Susott, R
    Ward, DE
    Reardon, J
    Griffith, DWT
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (D15) : 18865 - 18877
  • [6] Applying open-path Fourier transform infrared spectroscopy for measuring aerosols
    Wu, Chang-Fu
    Chen, Yen-Ling
    Chen, Chih-Chieh
    Yang, Tzu-Ting
    Chang, Pao-Erh
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2007, 42 (08): : 1131 - 1140
  • [7] Applying open-path Fourier transform infrared spectroscopy for measuring aerosols
    Wu, Chang-Fu
    Chen, Yen-Ling
    Chen, Chih-Chieh
    Yang, Tzu-Ting
    Chang, Pao-Erh
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2007, 42 (08): : 1131 - 1140
  • [8] Open-path Fourier transform infrared spectrometry characterization of low temperature combustion gases in biomass fuels
    de Castro, A. J.
    Lerma, A. M.
    Lopez, F.
    Guijarro, M.
    Diez, C.
    Hernando, C.
    Madrigal, J.
    INFRARED PHYSICS & TECHNOLOGY, 2007, 51 (01) : 21 - 30
  • [9] Quantifying flare combustion efficiency using a long wave infrared Fourier transform spectrometer
    Lapeyre, Paule
    Narayanan, Nishant Sriram
    Lariviere-Bastien, Martin
    Daun, Kyle J.
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2024, 40 (1-4)
  • [10] Minimizing the Effect of Extraneous Spikes in Open-Path Fourier Transform Infrared Interferograms
    Shao, Limin
    Griffiths, Peter R.