Long open-path measurements of greenhouse gases in air using near-infrared Fourier transform spectroscopy

被引:24
|
作者
Griffith, David W. T. [1 ]
Poehler, Denis [2 ]
Schmitt, Stefan [2 ]
Hammer, Samuel [2 ]
Vardag, Sanam N. [2 ,3 ]
Platt, Ulrich [2 ]
机构
[1] Univ Wollongong, Ctr Atmospher Chem, Wollongong, NSW, Australia
[2] Heidelberg Univ, Inst Environm Phys, Heidelberg, Germany
[3] Heidelberg Univ, Heidelberg Ctr Environm, Heidelberg, Germany
关键词
INSTRUMENTAL LINE-SHAPE; TRACE-GAS; METHANE EMISSIONS; CO2; SPECTROMETERS; CALIBRATION; NETWORK; FTIR; POLLUTANTS; ACCURACY;
D O I
10.5194/amt-11-1549-2018
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
In complex and urban environments, atmospheric trace gas composition is highly variable in time and space. Point measurement techniques for trace gases with in situ instruments are well established and accurate, but do not provide spatial averaging to compare against developing high-resolution atmospheric models of composition and meteorology with resolutions of the order of a kilometre. Open-path measurement techniques provide path average concentrations and spatial averaging which, if sufficiently accurate, may be better suited to assessment and interpretation with such models. Open-path Fourier transform spectroscopy (FTS) in the mid-infrared region, and differential optical absorption spectroscopy (DOAS) in the UV and visible, have been used for many years for open-path spectroscopic measurements of selected species in both clean air and in polluted environments. Near infrared instrumentation allows measurements over longer paths than mid-infrared FTS for species such as greenhouse gases which are not easily accessible to DOAS. In this pilot study we present the first open-path near-infrared (4000-10 000 cm(-1), 1.0-2.5 mu m) FTS measurements of CO2, CH4, O-2, H2O and HDO over a 1.5 km path in urban Heidelberg, Germany. We describe the construction of the open-path FTS system, the analysis of the collected spectra, several measures of precision and accuracy of the measurements, and the results a four-month trial measurement period in July-November 2014. The open-path measurements are compared to calibrated in situ measurements made at one end of the open path. We observe significant differences of the order of a few ppm for CO2 and a few tens of ppb for CH4 between the open-path and point measurements which are 2 to 4 times the measurement repeatability, but we cannot unequivocally assign the differences to specific local sources or sinks. We conclude that open-path FTS may provide a valuable new tool for investigations of atmospheric trace gas composition in complex, small-scale environments such as cities.
引用
收藏
页码:1549 / 1563
页数:15
相关论文
共 50 条
  • [41] A low-resolution spectrometer for open-path Fourier-transform infrared spectrometry
    Berry, RJ
    Hart, BK
    Richardson, RL
    Griffiths, PR
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1999, 3 (02): : 131 - 138
  • [42] Identification and quantitation of oxygenates in gasoline ampules using Fourier transform near-infrared and Fourier transform Raman spectroscopy
    Choquette, SJ
    Chesler, SN
    Duewer, DL
    Wang, SW
    OHaver, TC
    ANALYTICAL CHEMISTRY, 1996, 68 (20) : 3525 - 3533
  • [43] Measuring chemical emissions using open-path Fourier transform infrared (OP-FTIR) spectroscopy and computer-assisted tomography
    Todd, LA
    Ramanathan, M
    Mottus, K
    Katz, R
    Dodson, A
    Mihlan, G
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (11) : 1937 - 1947
  • [44] Detection of benzene and other gases with an open-path, static Fourier-transform UV spectrometer
    Patterson, BA
    Lenney, JP
    Sibbett, W
    Hirst, B
    Hedges, NK
    Padgett, MJ
    APPLIED OPTICS, 1998, 37 (15): : 3172 - 3175
  • [45] Developing and Evaluating Techniques for Localizing Pollutant Emission Sources with Open-Path Fourier Transform Infrared Measurements and Wind Data
    Wu, Chang-Fu
    Chen, Ching-Hui
    Chang, Shih-Ying
    Chang, Pao-Erh
    Shie, Ruei-Hou
    Sung, Lung-Yu
    Yang, Jen-Chih
    Su, Jen-Wei
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (10) : 1360 - 1369
  • [46] Detection of benzene and other gases with an open-path, static Fourier-transform UV spectrometer
    Patterson, Brett A.
    Lenney, James P.
    Sibbett, Wilson
    Hirst, Bill
    Hedges, Nigel K.
    Padgett, Miles J.
    Applied Optics, 1998, 37 (15): : 3172 - 3175
  • [47] Determination of peroxide value by Fourier transform near-infrared spectroscopy
    Li, H
    van de Voort, FR
    Ismail, AA
    Cox, R
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2000, 77 (02) : 137 - 142
  • [48] LONG-PATH FOURIER-TRANSFORM INFRARED-SPECTROSCOPY FOR POST-FUMIGATION INDOOR AIR MEASUREMENTS
    GREEN, M
    BIERMANN, HW
    SEIBER, JN
    ANALUSIS, 1992, 20 (08) : 455 - 460
  • [49] Fourier transform emission spectroscopy of YbO in the near-infrared region
    Melville, TC
    Gordon, I
    Tereszchuk, KA
    Coxon, JA
    Bernath, PF
    JOURNAL OF MOLECULAR SPECTROSCOPY, 2003, 218 (02) : 235 - 238
  • [50] Plane-integrated open-path Fourier transform infrared spectrometry methodology for anaerobic swine lagoon emission measurements
    Shores, RC
    Harris, DB
    Thompson, EL
    Vogel, CA
    Natschke, D
    Hashmonay, RA
    Wagoner, KR
    Modrak, M
    APPLIED ENGINEERING IN AGRICULTURE, 2005, 21 (03) : 487 - 492