Accuracy of Two Ultrasound-Guided Coracohumeral Ligament Injection Approaches: A Cadaveric Study

被引:4
|
作者
Majdalani, Carl [1 ]
Boudier-Reveret, Mathieu [1 ]
Pape, John [2 ]
Brismee, Jean-Michel [3 ]
Michaud, Johan [1 ]
Luong, Dien Hung [1 ]
Grabs, Detlev [4 ,5 ]
Chang, Ke-Vin [6 ]
Chen, Wen-Shiang [6 ]
Wu, Chueh Hung [6 ]
Sobczak, Stephane [4 ,5 ]
机构
[1] Ctr Hosp Univ Montreal, Dept Phys Med & Rehabil, Montreal, PQ, Canada
[2] Univ Hosp North Tees, Dept Physiotherapy, Stockton On Tees, England
[3] Texas Tech Univ, Hlth Sci Ctr, Sch Hlth Profess, Ctr Rehabil Res, Lubbock, TX 79430 USA
[4] Univ Quebec Trois Rivieres, Dept Anat, Quebec City, PQ, Canada
[5] Univ Quebec Trois Rivieres, Res Unit Clin & Funct Anat, Quebec City, PQ, Canada
[6] Natl Taiwan Univ Hosp, Dept Phys Med & Rehabil, Taipei, Taiwan
关键词
ADHESIVE CAPSULITIS; FROZEN SHOULDER; CORTICOSTEROID INJECTION; ROTATOR INTERVAL; ANATOMY; CONTRACTURE; RELEASE;
D O I
10.1002/pmrj.12079
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background Glenohumeral idiopathic adhesive capsulitis is a common shoulder condition that hinders functionality. Addressing the pathology has been extensively researched. Ultrasound (US)-guided injections have shown their efficacy. However, no study has been conducted to compare anatomical accuracy between different approaches in targeting the coracohumeral ligament (CHL). Objective To investigate whether US-guided injection of the CHL can be performed accurately using either the rotator interval (RI) or the coracoidal (CO) approach. Methods An experimental cadaveric case series. Setting Anatomy laboratory. Specimens Both shoulders of 13 Thiel-embalmed cadavers. Interventions Three physiatrists each injected a 0.1 mL bolus of colored dye in both shoulders of each cadaver using either the RI or the CO approach under US guidance. Each cadaver received a total of six injections (three injections per shoulder). The accuracy of the injection was determined following shoulder dissection by an anatomist. Main Outcome Measure The accuracy of the US-guided injection of the CHL. Results The RI approach yielded 36 accurate injections, giving it an accuracy of 100%. With the CO approach two injections were deemed inaccurate yielding an accuracy of 94%. There was no significant difference in accuracy between all operators. Conclusions US-guided injection of the CHL can be performed accurately with both the RI and CO approaches. The RI approach was likely to be more accurate.
引用
收藏
页码:989 / 995
页数:7
相关论文
共 50 条
  • [31] RE: Accuracy of Ultrasound-Guided Versus Palpation-Guided Acromioclavicular Joint Injections: A Cadaveric Study REPLY
    Peck, Evan
    PM&R, 2011, 3 (05) : 495 - 495
  • [32] Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study
    Jengojan, Suren
    Sorgo, Philipp
    Streicher, Johannes
    Snoj, Ziga
    Kasprian, Gregor
    Gruber, Gerlinde
    Bodner, Gerd
    RADIOLOGIA MEDICA, 2024, 129 (10): : 1513 - 1521
  • [33] Accuracy and efficacy of ultrasound-guided pes anserinus bursa injection
    Lee, Jong H.
    Lee, Jae U.
    Yoo, Seung W.
    JOURNAL OF CLINICAL ULTRASOUND, 2019, 47 (02) : 77 - 82
  • [34] FEASIBILITY AND ACCURACY OF ULTRASOUND-GUIDED SACROILIAC JOINT INJECTION IN DOGS
    Jones, Jeryl C.
    Gonzalez, Luis M.
    Larson, Martha M.
    Freeman, Larry E.
    Werre, Stephen R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (04) : 446 - 454
  • [35] Accuracy of blind versus ultrasound-guided suprapatellar bursal injection
    Park, Yong Bum
    Choi, Won Ah
    Kim, Yong-Kyun
    Lee, Sang Chul
    Lee, Ji Hae
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (01) : 20 - 25
  • [36] Ultrasound-guided quadratus lumborum block in sheep: A cadaveric study
    Mattaliano, Giorgio
    Verdier, Natali
    Klonner, Moriz E.
    Kyllar, Michal
    Kau-Strebinger, Silvio
    Otero, Pablo E.
    LABORATORY ANIMALS, 2024, 58 (04) : 334 - 344
  • [37] Ultrasound-guided infraclavicular approach to brachial plexus: A cadaveric study
    Herrero, Maria A. Perez
    Altinpulluk, Ece Yamak
    Perez, Mario Fajardo
    Zamorano, Carlos Salazar
    Vilches, Luis Valdes
    Galluccio, Felice
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (11) : 1014 - 1019
  • [38] Ultrasound-guided retrobulbar nerve block in horses: a cadaveric study
    Morath, Ute
    Luyet, Cedric
    Spadavecchia, Claudia
    Stoffel, Michael H.
    Hatch, Garry M.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (02) : 205 - 211
  • [39] Ultrasound-Guided Proximal Suprascapular Nerve Block: A Cadaveric Study
    Laumonerie, Pierre
    Ferre, Fabrice
    Cances, Jeremy
    Tibbo, Meagan E.
    Roumiguie, Mathieu
    Mansat, Pierre
    Minville, Vincent
    CLINICAL ANATOMY, 2018, 31 (06) : 824 - 829
  • [40] Ultrasound-guided core needle biopsy of deep fascia: A cadaveric study evaluating feasibility, accuracy and reliability
    Pirri, Carmelo
    Zabotti, Alen
    Pirri, Nina
    Petrelli, Lucia
    Giovannini, Ivan
    Macchi, Veronica
    Porzionato, Andrea
    Quartuccio, Luca
    De Caro, Raffaele
    De Vita, Salvatore
    Stecco, Carla
    CLINICAL ANATOMY, 2025, 38 (02) : 146 - 157