Ultrasound-guided thread versus ultrasound-guided needle release of the A1 pulley: a cadaveric study

被引:1
|
作者
Jengojan, Suren [1 ]
Sorgo, Philipp [1 ,2 ]
Streicher, Johannes [2 ]
Snoj, Ziga [3 ]
Kasprian, Gregor [1 ]
Gruber, Gerlinde [2 ]
Bodner, Gerd [4 ]
机构
[1] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Neuroradiol & Musculoskeletal Radiol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
[2] Karl Landsteiner Univ Hlth Sci, Dept Anat & Dev Biol, Dr Karl Dorrek Str 30, A-3500 Krems An Der Donau, Austria
[3] Univ Med Ctr Ljubljana, Inst Radiol, Zaloska 7, Ljubljana 1000, Slovenia
[4] Neuromuscular Imaging Ordinationszentrum Dobling, Heiligenstadter Str 46-48, A-1190 Vienna, Austria
来源
RADIOLOGIA MEDICA | 2024年 / 129卷 / 10期
关键词
Ultrasonography; Fingers; Decompression; Ligaments; Cadavers; TRIGGER FINGER; PERCUTANEOUS RELEASE; SAFETY; MANAGEMENT; EFFICACY; SURGERY; KNIFE;
D O I
10.1007/s11547-024-01875-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess and compare two ultrasound-guided, minimally invasive procedures to release the A1-pulley (needle release and thread release) regarding efficacy and safety in an anatomical specimen model. Materials and methods Twenty-one ultrasound-guided needle releases and 20 ultrasound-guided thread releases were performed on digits of Thiel-embalmed anatomical specimens. A scoring system was developed to assess ultrasound visibility, intervention outcome (incomplete, almost complete, or full transection of the A1 pulley), and injury to adjacent structures (neurovascular structures, tendons, A2 pulley). Statistical analysis was performed to compare the score of the two groups (group 1: needle release, group 2: thread release). A P-value of <= 0.05 was considered significant. Results Needle release was completely successful in 15 cases (71.5%), almost complete release was achieved in four cases (19%), and incomplete transection occurred in two cases (9.5%). Thread release was completely successful in 17 cases (85%), and almost complete transection was observed in the remaining three cases (15%). In both procedures no neurovascular structures were harmed. Slight injury of flexor tendons occurred in two cases (9.5%) in needle release and in five cases (25%) in thread release. There were no significant statistical differences between the groups regarding ultrasound visibility, intervention safety and outcome, (P > 0.05). Conclusion Ultrasound-guided needle release and ultrasound-guided thread release have similar success of release, both being effective and safe techniques for the release of the A1 pulley. [GRAPHICS] .
引用
收藏
页码:1513 / 1521
页数:9
相关论文
共 50 条
  • [1] Ultrasound-Guided A1 Pulley Release A Systematic Review
    Nakagawa, Hirotaka
    Redmond, Travis
    Colberg, Ricardo
    Latzka, Erek
    White, Mia S.
    Bowers, Robert L.
    Sussman, Walter I.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (11) : 2491 - 2499
  • [2] Ultrasound-Guided Percutaneous A1 Pulley Release by Acupotomy (Needle-Knife): A Cadaveric Study of Safety and Efficacy
    Yang, Jiaxuan
    Ma, Bin
    Zhong, Hao
    Zhang, Yue
    Zhu, Jiang
    Ni, Yong
    JOURNAL OF PAIN RESEARCH, 2022, 15 : 413 - 422
  • [3] Ultrasound-guided needle release of A1 pulley combined with corticosteroid injection is more effective than ultrasound-guided needle release alone in the treatment of trigger finger
    Wu, Yan-Yan
    Chen, Kai
    He, Fan-Ding
    Quan, Jie-Rong
    Guo, Xuan-Yan
    BMC SURGERY, 2022, 22 (01)
  • [4] Ultrasound-guided needle release of A1 pulley combined with corticosteroid injection is more effective than ultrasound-guided needle release alone in the treatment of trigger finger
    Yan-Yan Wu
    Kai Chen
    Fan-Ding He
    Jie-Rong Quan
    Xuan-Yan Guo
    BMC Surgery, 22
  • [5] Ultrasound-Guided Percutaneous Release of A1 Pulley by Using a Needle Knife: A Prospective Study of 41 Cases
    Pan, Min
    Sheng, Shuya
    Fan, Zhiqi
    Lu, Hao
    Yang, Hong
    Yan, Fei
    E, Zhansen
    FRONTIERS IN PHARMACOLOGY, 2019, 10
  • [6] Safety and efficacy of ultrasound-guided percutaneous A1 pulley release using a needle knife: An anatomical study
    Qiu, Zuyun
    Li, Hui
    Shen, Yifeng
    Jia, Yan
    Sun, Xiaojie
    Zhou, Qiaoyin
    Li, Shiliang
    Zhang, Weiguang
    FRONTIERS IN SURGERY, 2022, 9
  • [7] A1 pulley cutting potential and safety of three ultrasound-guided percutaneous A1 pulley release techniques for trigger finger: a cadaveric study
    de la Fuente, Javier
    Blasi, Marc
    Davila, Fernando
    Ribera, Angels
    Sala-Blanch, Xavier
    Balius, Ramon
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [8] Treatment of Trigger finger by ultrasound-guided needle release of a1 pulley: A series of 105 cases
    Chopin, Clement
    Le Guillou, Adrien
    Salmon, Jean Hugues
    Lellouche, Henri
    Richette, Pascal
    Maillet, Jeremy
    JOINT BONE SPINE, 2022, 89 (06)
  • [9] Ultrasound-guided minimally invasive thread release of carpal tunnel: a cadaveric study
    Jengojan, Suren
    Sorgo, Philipp
    Piacentini, Alessio
    Streicher, Johannes
    Albano, Domenico
    Kasprian, Gregor
    Moser, Veith
    Bodner, Gerd
    RADIOLOGIA MEDICA, 2025, : 524 - 533
  • [10] Percutaneous ultrasound-guided A1 pulley release utilizing a modified 20-gauge spinal needle
    Sederberg, Mark
    Sharma, Ragav
    Cushman, Daniel M.
    Finnoff, Jonathan T.
    PM&R, 2025, 17 (03) : 286 - 292