Accuracy of Two Ultrasound-Guided Coracohumeral Ligament Injection Approaches: A Cadaveric Study

被引:4
|
作者
Majdalani, Carl [1 ]
Boudier-Reveret, Mathieu [1 ]
Pape, John [2 ]
Brismee, Jean-Michel [3 ]
Michaud, Johan [1 ]
Luong, Dien Hung [1 ]
Grabs, Detlev [4 ,5 ]
Chang, Ke-Vin [6 ]
Chen, Wen-Shiang [6 ]
Wu, Chueh Hung [6 ]
Sobczak, Stephane [4 ,5 ]
机构
[1] Ctr Hosp Univ Montreal, Dept Phys Med & Rehabil, Montreal, PQ, Canada
[2] Univ Hosp North Tees, Dept Physiotherapy, Stockton On Tees, England
[3] Texas Tech Univ, Hlth Sci Ctr, Sch Hlth Profess, Ctr Rehabil Res, Lubbock, TX 79430 USA
[4] Univ Quebec Trois Rivieres, Dept Anat, Quebec City, PQ, Canada
[5] Univ Quebec Trois Rivieres, Res Unit Clin & Funct Anat, Quebec City, PQ, Canada
[6] Natl Taiwan Univ Hosp, Dept Phys Med & Rehabil, Taipei, Taiwan
关键词
ADHESIVE CAPSULITIS; FROZEN SHOULDER; CORTICOSTEROID INJECTION; ROTATOR INTERVAL; ANATOMY; CONTRACTURE; RELEASE;
D O I
10.1002/pmrj.12079
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background Glenohumeral idiopathic adhesive capsulitis is a common shoulder condition that hinders functionality. Addressing the pathology has been extensively researched. Ultrasound (US)-guided injections have shown their efficacy. However, no study has been conducted to compare anatomical accuracy between different approaches in targeting the coracohumeral ligament (CHL). Objective To investigate whether US-guided injection of the CHL can be performed accurately using either the rotator interval (RI) or the coracoidal (CO) approach. Methods An experimental cadaveric case series. Setting Anatomy laboratory. Specimens Both shoulders of 13 Thiel-embalmed cadavers. Interventions Three physiatrists each injected a 0.1 mL bolus of colored dye in both shoulders of each cadaver using either the RI or the CO approach under US guidance. Each cadaver received a total of six injections (three injections per shoulder). The accuracy of the injection was determined following shoulder dissection by an anatomist. Main Outcome Measure The accuracy of the US-guided injection of the CHL. Results The RI approach yielded 36 accurate injections, giving it an accuracy of 100%. With the CO approach two injections were deemed inaccurate yielding an accuracy of 94%. There was no significant difference in accuracy between all operators. Conclusions US-guided injection of the CHL can be performed accurately with both the RI and CO approaches. The RI approach was likely to be more accurate.
引用
收藏
页码:989 / 995
页数:7
相关论文
共 50 条
  • [21] A Two-Point Ultrasound-Guided Injection Technique for the Transversus Thoracis Plane Block: A Canine Cadaveric Study
    Alaman, Manuel
    Bonastre, Cristina
    Gonzalez-Marron, Adrian
    Gamez Maidanskaia, Ekaterina
    Laborda, Alicia
    ANIMALS, 2022, 12 (17):
  • [22] Accuracy of ultrasound-guided injections of thoracolumbar articular process joints in horses: A cadaveric study
    Fuglbjerg, V.
    Nielsen, J. V.
    Thomsen, P. D.
    Berg, L. C.
    EQUINE VETERINARY JOURNAL, 2010, 42 (01) : 18 - 22
  • [23] Effectiveness of ultrasound-guided fascia hydrorelease on the coracohumeral ligament in patients with global limitation of the shoulder range of motion: a pilot study
    Kimura, Hiroaki
    Suda, Masei
    Kobayashi, Tadashi
    Suzuki, Shigeki
    Fukui, Sho
    Obata, Hideaki
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [24] Accuracy of ultrasound-guided versus fluoroscopically guided contrast-controlled piriformis injections - A cadaveric study
    Finnoff, Jonathan T.
    Hurdle, Mark Friedrich B.
    Smith, Jay
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (08) : 1157 - 1163
  • [25] Ultrasound-guided transversus abdominis plane injection with computed tomography correlation: a cadaveric study
    Moeschler, Susan M.
    Murthy, Naveen S.
    Hoelzer, Bryan C.
    Gazelka, Halena M.
    Rho, Richard H.
    Pingree, Matthew J.
    JOURNAL OF PAIN RESEARCH, 2013, 6 : 493 - 496
  • [26] Ultrasound-guided corticosteroid injection in rheumatology: accuracy or efficacy?
    Iagnocco, Annamaria
    Naredo, Esperanza
    RHEUMATOLOGY, 2010, 49 (08) : 1427 - 1428
  • [27] Ultrasound-guided injection of the ankle joint: cadaveric investigation of the anterolateral approach
    Vincenzo Ricci
    Kamal Mezian
    Ke-Vin Chang
    Kentaro Onishi
    Murat Kara
    Ondřej Naňka
    Levent Özçakar
    Surgical and Radiologic Anatomy, 2024, 46 : 241 - 248
  • [28] Ultrasound-guided injection of the ankle joint: cadaveric investigation of the anterolateral approach
    Ricci, Vincenzo
    Mezian, Kamal
    Chang, Ke-Vin
    Onishi, Kentaro
    Kara, Murat
    Nanka, Ondrej
    Ozcakar, Levent
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (02) : 241 - 248
  • [29] Ultrasound-guided injection of the elbow: Cadaveric description for the proximal to distal approach
    Ricci, Vincenzo
    Mezian, Kamal
    Chang, Ke-Vin
    Mittal, Nimish
    Kara, Murat
    Nanka, Ondrej
    Ozcakar, Levent
    PM&R, 2023, 15 (11) : 1431 - 1435
  • [30] Ultrasound-Guided Thoracic Paravertebral Blockade: A Cadaveric Study
    Cowie, Brian
    McGlade, Desmond
    Ivanusic, Jason
    Barrington, Michael J.
    ANESTHESIA AND ANALGESIA, 2010, 110 (06): : 1735 - 1739