Detection and Measurement of Stones With Ultrasound Strain Elastography A Phantom Study

被引:3
|
作者
Li, Qian [1 ]
Chen, Lei [1 ]
Halpern, Elkan F. [2 ]
Samir, Anthony E. [3 ]
机构
[1] Peking Univ, Hlth Sci Ctr, Hosp 1, Dept Ultrasound, Beijing 100871, Peoples R China
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Inst Technol Assessment, Boston, MA USA
[3] Harvard Univ, Massachusetts Gen Hosp, Dept Radiol, Sch Med, 55 Fruit St, Boston, MA 02114 USA
关键词
ultrasonography; strain elastography; stone; horizontal dimension; vertical dimension; TIME TISSUE ELASTOGRAPHY; SOLID BREAST MASSES; DIAGNOSIS; BENIGN; SONOGRAPHY; MANAGEMENT; FIBROSIS;
D O I
10.1097/RUQ.0000000000000204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The sonoelastographic appearances of stones in a phantom were evaluated in this study. Ten stones were embedded into a tissue-mimicking meat phantom. The stone axial (vertical) and transverse (horizontal) dimensions measured by an electronic digital caliper, gray-scale ultrasound, and strain elastography (SE) were compared in 5 groups with stones embedded at different depths. In this study, physically measured axial and transverse stone dimensions were 1.17 to 6.86 and 1.30 to 11.15 mm, respectively. Strain elastography showed a characteristic 3-layer pattern associated with stones, comprising a superficial transition region, a hard region, and a deep transition region. As SE data were available in group 5, only data of groups 1 to 4 were analyzed. Compared with physical measurements, measurement mean errors of SE horizontal and SE vertical dimensions ranged from -0.20 to 0.42 mm and from -1.28 to -0.05 mm, respectively, in the 4 groups. Paired t testing demonstrated a significant horizontal dimension measurement error difference between B mode and SE method in group 4 (0.44 vs -0.20 mm, P < 0.05; F = 1.18, P > 0.05), but not in the other groups. Strain elastography horizontal dimension measurement error was not statistically correlated with stone size in the 4 groups. Strain elastography vertical dimension measurement error significantly correlated with stone size only in group 4 (P < 0.05). Preliminary results indicate that stone horizontal and vertical dimensions can be measured using SE in a soft tissue phantom, including when shadowing precludes measurement of vertical dimension on conventional 2-dimensional ultrasound. These results provide substantial motivation to further investigate SE as a modality to image stones in clinical practice.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 50 条
  • [41] Precision and Test-Retest Repeatability of Stiffness Measurement with MR Elastography: A Multicenter Phantom Study
    Ozkaya, Efe
    Kennedy, Paul
    Chen, Jun
    Bane, Octavia
    Dillman, Jonathan R.
    Jhaveri, Kartik S.
    Ohliger, Michael A.
    Rossman, Phillip J.
    Tkach, Jean A.
    Doucette, John T.
    Venkatesh, Sudhakar K.
    Ehman, Richard L.
    Taouli, Bachir
    RADIOLOGY, 2024, 311 (02)
  • [42] Quantitative Assessment of Tissue Stiffness Using Transfer Learning Ultrasound Elastography: A Breast Cancer Phantom Study
    An, Justin
    Abdus-Shakur, Tasneem
    Denis, Max
    IEEE SENSORS LETTERS, 2023, 7 (10)
  • [43] Ultrasound elastography using a regularized modified error in constitutive equations (MECE) approach: a comprehensive phantom study
    Ghavami, S.
    Babaniyi, O.
    Adabi, S.
    Rosen, D.
    Alizad, A.
    Aquino, W.
    Fatemi, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22):
  • [44] Inter- and intraobserver reproducibility of Strain and 2D Shear Wave Elastography - a phantom study
    Dudea-Simon, Marina
    Dudea, Sorin Marian
    Schiau, Calin
    Ciortea, Razvan
    Malutan, Andrei
    Simon, Vasile
    Burde, Alexandru
    Ciurea, Anca
    Mihu, Dan
    MEDICAL ULTRASONOGRAPHY, 2021, 23 (04) : 430 - 437
  • [45] Strain Ratio of Ultrasound Elastography for the Evaluation of Tendon Elasticity
    Chang, Ke-Vin
    Wu, Wei-Ting
    Chen, Ing-Jeng
    Lin, Che-Yu
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (03) : 384 - 385
  • [46] Application of strain elastography ultrasound to the endometrium of normal women
    Shen, Guili
    Zhang, Xueling
    Qin, Lei
    Wu, Yiyun
    Li, Hongbo
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [47] Advanced head and neck ultrasound technique: strain elastography
    Dombrowski, Tobias
    Pursche, Nils
    Beutner, Dirk
    Bevis, Nicholas
    LARYNGO-RHINO-OTOLOGIE, 2023, 102 (06) : 410 - 411
  • [48] Comparative study between conventional ultrasound strain elastography and an AI-enabled elastography software in differentiating breast masses
    Eman Faker Kamal
    Rasha Mohamed Kamal
    Ahmed M. Mahmoud
    Mahmoud Ibrahim Mekhaimar
    Mennatallah Mohamed Hanafy
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [49] Comparative study between conventional ultrasound strain elastography and an AI-enabled elastography software in differentiating breast masses
    Kamal, Eman Faker
    Kamal, Rasha Mohamed
    Mahmoud, Ahmed M.
    Mekhaimar, Mahmoud Ibrahim
    Hanafy, Mennatallah Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01):
  • [50] Measurement of the Shear Modulus of an Ultrasound Tissue Phantom
    Park, Jeong Man
    Choi, Seung Min
    Kwon, Sung Jae
    Jeong, Mok Kun
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2012, 31 (06): : 399 - 409