Detection and Measurement of Stones With Ultrasound Strain Elastography A Phantom Study

被引:3
|
作者
Li, Qian [1 ]
Chen, Lei [1 ]
Halpern, Elkan F. [2 ]
Samir, Anthony E. [3 ]
机构
[1] Peking Univ, Hlth Sci Ctr, Hosp 1, Dept Ultrasound, Beijing 100871, Peoples R China
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Inst Technol Assessment, Boston, MA USA
[3] Harvard Univ, Massachusetts Gen Hosp, Dept Radiol, Sch Med, 55 Fruit St, Boston, MA 02114 USA
关键词
ultrasonography; strain elastography; stone; horizontal dimension; vertical dimension; TIME TISSUE ELASTOGRAPHY; SOLID BREAST MASSES; DIAGNOSIS; BENIGN; SONOGRAPHY; MANAGEMENT; FIBROSIS;
D O I
10.1097/RUQ.0000000000000204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The sonoelastographic appearances of stones in a phantom were evaluated in this study. Ten stones were embedded into a tissue-mimicking meat phantom. The stone axial (vertical) and transverse (horizontal) dimensions measured by an electronic digital caliper, gray-scale ultrasound, and strain elastography (SE) were compared in 5 groups with stones embedded at different depths. In this study, physically measured axial and transverse stone dimensions were 1.17 to 6.86 and 1.30 to 11.15 mm, respectively. Strain elastography showed a characteristic 3-layer pattern associated with stones, comprising a superficial transition region, a hard region, and a deep transition region. As SE data were available in group 5, only data of groups 1 to 4 were analyzed. Compared with physical measurements, measurement mean errors of SE horizontal and SE vertical dimensions ranged from -0.20 to 0.42 mm and from -1.28 to -0.05 mm, respectively, in the 4 groups. Paired t testing demonstrated a significant horizontal dimension measurement error difference between B mode and SE method in group 4 (0.44 vs -0.20 mm, P < 0.05; F = 1.18, P > 0.05), but not in the other groups. Strain elastography horizontal dimension measurement error was not statistically correlated with stone size in the 4 groups. Strain elastography vertical dimension measurement error significantly correlated with stone size only in group 4 (P < 0.05). Preliminary results indicate that stone horizontal and vertical dimensions can be measured using SE in a soft tissue phantom, including when shadowing precludes measurement of vertical dimension on conventional 2-dimensional ultrasound. These results provide substantial motivation to further investigate SE as a modality to image stones in clinical practice.
引用
收藏
页码:272 / 278
页数:7
相关论文
共 50 条
  • [21] Cross-Validation of Magnetic Resonance Elastography and Ultrasound-Based Transient Elastography: A Preliminary Phantom Study
    Oudry, Jennifer
    Chen, Jun
    Glaser, Kevin J.
    Miette, Veronique
    Sandrin, Laurent
    Ehman, Richard L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1145 - 1150
  • [22] Strain ultrasound elastography for liver diseases
    Kan, Quan-Cheng
    Cui, Xin-Wu
    Chang, Jian-Min
    Dietrich, Christoph F.
    JOURNAL OF HEPATOLOGY, 2015, 63 (02) : 534 - 534
  • [23] MOTORIZING AND OPTIMIZING ULTRASOUND STRAIN ELASTOGRAPHY FOR DETECTION OF INTRAUTERINE GROWTH RESTRICTION PREGNANCIES
    Saw, Shier Nee
    Low, Jess Yi Ru
    Mattar, Citra Nurfarah Zaini
    Biswas, Arijit
    Chen, Lujie
    Yap, Choon Hwai
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (03): : 532 - 543
  • [24] Muscle hardness measurement by using ultrasound elastography: a feasibility study
    Niitsu, Mamoru
    Michizaki, Akie
    Endo, Asako
    Takei, Hitoshi
    Yanagisawa, Osamu
    ACTA RADIOLOGICA, 2011, 52 (01) : 99 - 105
  • [25] SOURCES OF VARIABILITY IN SHEAR WAVE SPEED AND DISPERSION QUANTIFICATION WITH ULTRASOUND ELASTOGRAPHY: A PHANTOM STUDY
    Martiartu, Naiara Korta
    Nambiar, Sherin
    Kirchner, Iara Nascimento
    Paverd, Catherine
    Cester, Davide
    Frauenfelder, Thomas
    Ruby, Lisa
    Romingertagedend, Marga B.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (12): : 3529 - 3542
  • [26] Reliability of shoulder muscle stiffness measurement using strain ultrasound elastography and an acoustic coupler
    Shimoyama, Daisuke
    Shitara, Hitoshi
    Hamano, Noritaka
    Ichinose, Tsuyoshi
    Sasaki, Tsuyoshi
    Yamamoto, Atsushi
    Kobayashi, Tsutomu
    Tajika, Tsuyoshi
    Takagishi, Kenji
    Chikuda, Hirotaka
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (01) : 91 - 96
  • [27] Optimal Endobronchial Ultrasound Strain Elastography Assessment Strategy: An Explorative Study
    Verhoeven, Roel L. J.
    de Korte, Chris L.
    van der Heijden, Erik H. F. M.
    RESPIRATION, 2019, 97 (04) : 337 - 347
  • [28] Reliability of shoulder muscle stiffness measurement using strain ultrasound elastography and an acoustic coupler
    Daisuke Shimoyama
    Hitoshi Shitara
    Noritaka Hamano
    Tsuyoshi Ichinose
    Tsuyoshi Sasaki
    Atsushi Yamamoto
    Tsutomu Kobayashi
    Tsuyoshi Tajika
    Kenji Takagishi
    Hirotaka Chikuda
    Journal of Medical Ultrasonics, 2021, 48 : 91 - 96
  • [29] Preliminary Study on the Evaluation of Liver Fibrosis Using Endoscopic Ultrasound Elastography and Transabdominal Ultrasound Transient Elastography Combined with Strain Ratio
    Yao, Dun-Wei
    Jiang, Hai-Xing
    Qin, Shan-Yu
    HEPATITIS MONTHLY, 2024, 24 (01)
  • [30] Design, Development and Characterization of Cyst Phantom for Ultrasound Elastography Applications
    Kumar, Kishore
    Andrews, M. E.
    Jayashankar, V.
    Mishra, A. K.
    Suresh, S.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2972 - +