Spectral analysis applied to hepatobiliary dynamic scintigraphy with Tc-99(m)-N-pyridoxyl-5-methyltryptophan

被引:5
|
作者
Murase, K
Tsuda, T
Mochizuki, T
Tanada, S
Ikezoe, J
机构
关键词
D O I
10.1097/00006231-199711000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was performed to evaluate the application of spectral analysis (SA) to hepatobiliary dynamic scintigraphy with Tc-99(m)-N-pyridoxyl-5-methyltryptophan (Tc-99(m)-PMT) in 82 patients with a wide range of liver function, and to compare it with compartment analysis (CA) and deconvolution analysis (DA). The rate of uptake of PMT by the liver from the blood (k(1)) obtained by SA (y, min(-1)) agreed well with the k(1) value obtained using CA (x, min(-1)) (y = 1.079x + 0.000, r = 0.993, standard error of the estimate (S.E.E.) = 0.042 min(-1)). The mean residence time (MRT) of PMT in the liver obtained by SA (y, min) also agreed well with the MRT value obtained by DA (x, min) (y = 1.036x - 0.759, r = 0.967 S.E.E. = 1.014 min) and that obtained by CA (x, min) (y = 0.859x + 1.006, r = 0.931, S.E.E. 1.428 min). The fraction of the measured blood activity superimposed on the true liver activity (f) obtained by SA (y) correlated well with the f value obtained by CA (x) (y = 1.168x - 0.004, r = 0.924, S.E.E. = 0.043). We conclude that the application of SA to hepatobiliary dynamic scintigraphy with PMT appears to be useful in evaluating the functional status of the liver, since it facilitates the interpretation of the kinetic behaviour of PMT in the liver and allows us to extract quantitative parameters corresponding to those obtained by CA or DA.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 33 条
  • [21] Quantification of [Tc-99m]-mebrofenin hepatobiliary scintigraphy with Patlak-Rutland analysis
    Peng, Jia Xin
    Schembri, Geoff
    Bailey, Dale
    Chan, David
    Willowson, Kathy
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [22] DIAGNOSIS OF CONJUGATED BILIRUBIN ICTERUS - HEPATOBILIARY DYNAMIC SCINTIGRAPHY USING TC-99M PYRIDOXYLIDENE GLUTAMATE
    DELALANDE, JP
    MOSNIER, H
    BEHAR, A
    PICARD, D
    ALEXANDRE, JH
    MEDECINE & CHIRURGIE DIGESTIVES, 1980, 9 (01): : 15 - 20
  • [23] RENAL PARENCHYMAL DETERMINATION AND ANALYSIS DURING DYNAMIC TC-99 (M) DTPA SCANS IN CHILDREN
    VIVIAN, GC
    BARRATT, TM
    TODDPOKROPEK, A
    GORDON, I
    NUCLEAR MEDICINE COMMUNICATIONS, 1984, 5 (01) : 35 - 40
  • [24] COMBINED COMPUTER AND NOMOGRAPHIC ANALYSIS OF TC-99M DYNAMIC KIDNEY SCINTIGRAPHY
    BLAHA, V
    NICEK, F
    KORAL, V
    KOLINSKA, J
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1983, 4 (04): : 451 - 454
  • [25] Precision of the gallbladder ejection fraction obtained with Tc-99m- pyridoxyl-5-methyl-tryptophan (99mTc-PMT) hepatobiliary scintigraphy as compared with the contraction ratio in three-dimensional computed tomography
    Uchiyama K.
    Kuniyasu Y.
    Higashi S.T.
    Shen Y.
    Niio Y.
    Hasebe S.
    Matsuoka S.
    Shima H.
    Shinohara H.
    Takizawa K.
    Obuchi M.
    Honda M.
    Hirata N.
    Annals of Nuclear Medicine, 1997, 11 (2) : 123 - 128
  • [26] Clinical evaluation of spectral analysis for the quantification of chronic liver disease with Tc-99m PMT and dynamic scintigraphy.
    Tsuda, T
    Murase, K
    Tanada, S
    Ikezoe, J
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1071 - 1071
  • [27] Comparison of the efficacies of Tc-99m N-pyridoxyl-5-methyl tryptophan, Tc-99m hydroxymethylene diphosphonate, and F-18 fluorodeoxyglucose in detecting bone metastasis of hepatocellular carcinoma
    Yamane, T.
    Nagata, T.
    Yoshiya, K.
    Ito, S.
    Fukaya, N.
    Ito, S.
    Uchida, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S288 - S288
  • [28] Small-angle Compton Scatter Artifact in Tc-99m-IDA Hepatobiliary Scintigraphy Resulting in the Breast Overlying the Liver in Planar Dynamic Imaging
    Qutbi, Mohsen
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2021, 30 (01) : 54 - 56
  • [29] TC-99M(SN)PYRIDOXYLIDENEAMINATES AND TC-99M(SN)-N-PYRIDOXYLAMINATES - RECENT DEVELOPMENT OF A SERIES OF HEPATOBILIARY IMAGING AGENTS, WITH SPECIAL ATTENTION TO RESULTS OF HPLC ANALYSIS
    KATOAZUMA, M
    UEDA, H
    HAZUE, M
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1982, 26 (03): : 149 - 149
  • [30] Kinetic analysis using asialoglycoprotein receptor scintigraphy with Tc-99m GSA dynamic SPECT/CT for assessment of hepatic function
    Fukuda, Y.
    Sanomura, T.
    Okuda, H.
    Yamamoto, Y.
    Okano, K.
    Kudomi, N.
    Nishiyama, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S862 - S862