Spectral analysis applied to hepatobiliary dynamic scintigraphy with Tc-99(m)-N-pyridoxyl-5-methyltryptophan

被引:5
|
作者
Murase, K
Tsuda, T
Mochizuki, T
Tanada, S
Ikezoe, J
机构
关键词
D O I
10.1097/00006231-199711000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was performed to evaluate the application of spectral analysis (SA) to hepatobiliary dynamic scintigraphy with Tc-99(m)-N-pyridoxyl-5-methyltryptophan (Tc-99(m)-PMT) in 82 patients with a wide range of liver function, and to compare it with compartment analysis (CA) and deconvolution analysis (DA). The rate of uptake of PMT by the liver from the blood (k(1)) obtained by SA (y, min(-1)) agreed well with the k(1) value obtained using CA (x, min(-1)) (y = 1.079x + 0.000, r = 0.993, standard error of the estimate (S.E.E.) = 0.042 min(-1)). The mean residence time (MRT) of PMT in the liver obtained by SA (y, min) also agreed well with the MRT value obtained by DA (x, min) (y = 1.036x - 0.759, r = 0.967 S.E.E. = 1.014 min) and that obtained by CA (x, min) (y = 0.859x + 1.006, r = 0.931, S.E.E. 1.428 min). The fraction of the measured blood activity superimposed on the true liver activity (f) obtained by SA (y) correlated well with the f value obtained by CA (x) (y = 1.168x - 0.004, r = 0.924, S.E.E. = 0.043). We conclude that the application of SA to hepatobiliary dynamic scintigraphy with PMT appears to be useful in evaluating the functional status of the liver, since it facilitates the interpretation of the kinetic behaviour of PMT in the liver and allows us to extract quantitative parameters corresponding to those obtained by CA or DA.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 33 条
  • [31] QUANTIFICATION OF TRACER KINETICS IN INTRAHEPATIC AND EXTRA-HEPATIC BILE-DUCTS AND OF GALLBLADDER FILLING RATES IN HEPATOBILIARY DYNAMIC SCINTIGRAPHY USING TC-99M-IDA DERIVATES
    STRITZKE, P
    DENKHAUS, H
    MONTZ, R
    KLAPDOR, R
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 1983, 22 (04): : 181 - 186
  • [32] Clinical usefulness of spectral analysis and dynamic SPECT with Tc-99m-diethylenetriamine pentaacetic acid galactosyl human serum albumin (Tc-99m-GSA): A quantitative assessment of liver function.
    Yano, M
    Kato, J
    Terao, T
    Watanabe, A
    Takahashi, Y
    Chiba, H
    Sogabe, I
    Higashino, H
    Murase, K
    Mochizuki, T
    GASTROENTEROLOGY, 2003, 124 (04) : A773 - A773
  • [33] DYNAMIC PRESSURE-VOLUME GRINDING ANALYSIS UNDER THERAPEUTIC INTERVENTION - COMPUTER-AIDED SIMULTANEOUS LV VOLUME REGISTRATION BY SCINTIGRAPHY (TC-99M) AND THE BAAN CONDUCTANCE CATHETER
    THORMANN, J
    KRAMER, W
    KINDLER, M
    KREMER, FP
    NEUSS, H
    BILGIN, Y
    SCHLEPPER, M
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 79 - 79