We present a device that has been developed for delivering prostate focal thermal therapy under magnetic resonance imaging (MRI) guidance. Unlike most existing devices, ours is capable of delivering needles to targets in the prostate without removing the patient from the scanner. This feature greatly reduces procedure time and increases accuracy. The device consists of a mechanical linkage encoded with optical incremental encoders, and is manually actuated. A custom magnetic resonance (MR) compatible alignment interface allows the user to manually align the device to its target with high accuracy inbore in very short time. The use of manual actuation over motors greatly reduces the complexity and bulk of the system, making it much more compact and portable. This is important when dealing with such tight space constraints. Needle targeting experiments in gel phantoms have demonstrated the device's ability to deliver needles with an accuracy of 2.1 +/- 1.3 mm.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 50 条
  • [41] Design and Development of a 3-Axis MRI-compatible Force Sensor
    Tan, U-Xuan
    Yang, Bo
    Gullapalli, Rao
    Desai, Jaydev P.
    2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, : 2586 - 2591
  • [42] Simulated weight-bearing MRI of the knee: Initial experience using an MRI-compatible compression device
    Zoga, AC
    Elias, I
    Bergin, D
    Morrison, WB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 50 - 50
  • [43] Accuracy of seed reconstruction in prostate postplanning studied with a CT- and MRI-compatible phantom
    De Brabandere, Marisol
    Kirisits, Christian
    Peeters, Ronald
    Haustermans, Karin
    Van den Heuvel, Frank
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) : 190 - 197
  • [44] Design of an MRI-Compatible Modularized Needle Driver for In-Bore MRI-Guided Prostate Interventions
    Kim, Ki-Young
    Li, Meng
    Gonenc, Berk
    Shang, Weijian
    Eslami, Sohrab
    Iordachita, Iulian
    2015 15TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2015, : 1520 - 1525
  • [45] Design of a force sensing needle guide for an MRI-compatible robotic prostate biopsy system
    Liu, Rongrong
    Ko, Seong Young
    2022 9TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB 2022), 2022,
  • [46] Cardiac pre-load alteration with MRI-compatible lower body suction device
    Gergely V Szantho
    Chris B Lawton
    Stephen Lyen
    Chiara Bucciarelli-Ducci
    Nathan E Manghat
    Mark S Turner
    Michael P Frenneaux
    Mark Hamilton
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [47] Experimental validation of a novel MRI-compatible HIFU device for the treatment of superficial venous insufficiency
    Salomir, Rares
    Pichardo, Samuel
    Petrusca, Lorena
    Angel, Yves
    Lacoste, Francois
    Chapelon, Jean-Yves
    6th International Symposium on Therapeutic Ultrasound, 2007, 911 : 111 - 116
  • [48] Silicon photomultiplier modules for MRI-compatible PET
    Sul, Woo-Suk
    Kim, Hyoungtaek
    Cho, Gyuseong
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [49] The modelling and design of an MRI-compatible cryosurgical probe
    Kossel, L.
    Pfotenhauer, J.
    Harter, R.
    ADVANCES IN CRYOGENIC ENGINEERING, 2020, 755
  • [50] Design and validation of an MRI-compatible mechatronic system for needle delivery to localized prostate cancer
    Knull, Eric
    Bax, Jeffrey Scott
    Park, Claire Keun Sun
    Tessier, David
    Fenster, Aaron
    MEDICAL PHYSICS, 2021, 48 (09) : 5283 - 5299