Development of an MRI-Compatible Device for Prostate Focal Therapy

被引:0
|
作者
Cepek, Jeremy [1 ]
Chronik, Blaine [1 ]
Lindner, Uri [2 ]
Trachtenberg, John [2 ]
Fenster, Aaron [1 ]
机构
[1] Western Univ, Robarts Res Inst, London, ON, Canada
[2] Univ Hlth Network, Div Urol, Dept Surg Oncol, Toronto, ON, Canada
关键词
MRI-compatible device; prostate cancer; focal thermal therapy; ACCURACY; ROBOT;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a device that has been developed for delivering prostate focal thermal therapy under magnetic resonance imaging (MRI) guidance. Unlike most existing devices, ours is capable of delivering needles to targets in the prostate without removing the patient from the scanner. This feature greatly reduces procedure time and increases accuracy. The device consists of a mechanical linkage encoded with optical incremental encoders, and is manually actuated. A custom magnetic resonance (MR) compatible alignment interface allows the user to manually align the device to its target with high accuracy inbore in very short time. The use of manual actuation over motors greatly reduces the complexity and bulk of the system, making it much more compact and portable. This is important when dealing with such tight space constraints. Needle targeting experiments in gel phantoms have demonstrated the device's ability to deliver needles with an accuracy of 2.1 +/- 1.3 mm.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 50 条
  • [21] Special MRI-Compatible Leads
    Hansky, Bert
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2012, 109 (39): : 643 - 644
  • [22] An MRI-Compatible Robotic System With Hybrid Tracking for MRI-Guided Prostate Intervention
    Krieger, Axel
    Iordachita, Iulian I.
    Guion, Peter
    Singh, Anurag K.
    Kaushal, Aradhana
    Menard, Cynthia
    Pinto, Peter A.
    Camphausen, Kevin
    Fichtinger, Gabor
    Whitcomb, Louis L.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (11) : 3049 - 3060
  • [23] Design Requirements and Feasibility Study for a 3-DOF MRI-Compatible Robotic Device for MRI-Guided Prostate Intervention
    Bohren, Jonathan
    Iordachita, Iulian
    Whitcomb, Louis L.
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 677 - 682
  • [24] An MRI-compatible caloric stimulation device for the investigation of human vestibular cortex
    Frank, Sebastian M.
    Greenlee, Mark W.
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 235 : 208 - 218
  • [25] Pneumatically operated MRI-compatible needle placement robot for prostate interventions
    Fischer, Gregory S.
    Iordachita, Iulian
    Csoma, Csaba
    Tokuda, Junichi
    Mewes, Philip W.
    2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-9, 2008, : 2489 - +
  • [26] Development of a QCT- and MRI-compatible Muscle Phantom.
    Wong, Andy Kin On
    Merali, Zamir
    Adachi, Jonathan
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S341 - S342
  • [27] Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI
    Duppenbecker, Peter M.
    Weissler, Bjoern
    Gebhardt, Pierre
    Schug, David
    Wehner, Jakob
    Marsden, Paul K.
    Schulz, Volkmar
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (01):
  • [28] Development of a Novel Wearable MRI-Compatible Finger Assistive Robot
    Liu, Kun
    Hasegawa, Yasuhisa
    2017 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2017,
  • [29] An MRI-compatible foot-loading device for assessment of internal tissue deformation
    Petre, Marc
    Erdemir, Ahmet
    Cavanagh, Peter R.
    JOURNAL OF BIOMECHANICS, 2008, 41 (02) : 470 - 474
  • [30] The MRI-compatible neonatal incubator in practice
    Lane, Annah
    Chuk, Lai-Man R.
    Colditz, Paul B.
    Coulthard, Alan
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2013, 49 (09) : E377 - E380