Development of an MRI-Compatible Device for Prostate Focal Therapy

被引:0
|
作者
Cepek, Jeremy [1 ]
Chronik, Blaine [1 ]
Lindner, Uri [2 ]
Trachtenberg, John [2 ]
Fenster, Aaron [1 ]
机构
[1] Western Univ, Robarts Res Inst, London, ON, Canada
[2] Univ Hlth Network, Div Urol, Dept Surg Oncol, Toronto, ON, Canada
关键词
MRI-compatible device; prostate cancer; focal thermal therapy; ACCURACY; ROBOT;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a device that has been developed for delivering prostate focal thermal therapy under magnetic resonance imaging (MRI) guidance. Unlike most existing devices, ours is capable of delivering needles to targets in the prostate without removing the patient from the scanner. This feature greatly reduces procedure time and increases accuracy. The device consists of a mechanical linkage encoded with optical incremental encoders, and is manually actuated. A custom magnetic resonance (MR) compatible alignment interface allows the user to manually align the device to its target with high accuracy inbore in very short time. The use of manual actuation over motors greatly reduces the complexity and bulk of the system, making it much more compact and portable. This is important when dealing with such tight space constraints. Needle targeting experiments in gel phantoms have demonstrated the device's ability to deliver needles with an accuracy of 2.1 +/- 1.3 mm.
引用
收藏
页码:455 / 462
页数:8
相关论文
共 50 条
  • [31] Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast
    Larson, BT
    Erdman, AG
    Tsekos, NV
    Yacoub, E
    Tsekos, PV
    Koutlas, LG
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 458 - 465
  • [32] MRI-compatible cardiac pacing catheter
    Hofman, MBM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) : 612 - 612
  • [33] Special MRI-Compatible Leads Reply
    Zobel, Carsten
    Bovenschulte, Henning
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2012, 109 (39): : 644 - 644
  • [34] High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions
    Su, Hao
    Camilo, Alex
    Cole, Gregory A.
    Hata, Nobuhiko
    Tempany, Clare M.
    Fischer, Gregory S.
    MEDICINE MEETS VIRTUAL REALITY 18, 2011, 163 : 623 - 629
  • [35] A MRI-compatible system for whisker stimulation
    Li, Limin
    Weiss, Craig
    Talk, Andrew C.
    Disterhoft, John F.
    Wyrwicz, Alice M.
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 205 (02) : 305 - 311
  • [36] Preliminary Evaluation of a MRI-compatible Modular Robotic System for MRI-guided Prostate Interventions
    Song, Sang-Eun
    Cho, Nathan
    Tokuda, Junichi
    Hata, Nobuhiko
    Tempany, Clare
    Fichtinger, Gabor
    Iordachita, Iulian
    2010 3RD IEEE RAS AND EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS, 2010, : 796 - 801
  • [37] A modular approach to MRI-compatible robotics
    Elhawary, Haytham
    Zivanovic, Aleksandar
    Rea, Marc
    Davies, Brian L.
    Besant, Collin
    McRobbie, Donald
    Desouza, Nandita M.
    Young, Ian
    Lamperth, Michael U.
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2008, 27 (03): : 35 - 41
  • [38] Development of a Novel MRI-Compatible Applicator for Intensity Modulated Rectal Brachytherapy
    Thibodeau-Antonacci, A.
    Vuong, T.
    Liontis, B.
    Rayes, F.
    Pande, S.
    Enger, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E240 - E240
  • [39] Toward the Development of a Flexible Mesoscale MRI-Compatible Neurosurgical Continuum Robot
    Kim, Yeongjin
    Cheng, Shing Shin
    Diakite, Mahamadou
    Gullapalli, Rao P.
    Simard, J. Marc
    Desai, Jaydev P.
    IEEE TRANSACTIONS ON ROBOTICS, 2017, 33 (06) : 1386 - 1397
  • [40] Development of an MRI-Compatible, Compact, Rotary-Linear Piezoworm Actuator
    El Bannan, Khaled
    Chronik, Blaine A.
    Salisbury, Shaun P.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (01):