On- and off-line monitoring of ion beam treatment

被引:48
|
作者
Parodi, Katia [1 ]
机构
[1] Univ Munich, Dept Med Phys, D-85748 Garching, Germany
关键词
Ion beam therapy; Range verification; Positron Emission Tomography; Prompt gamma imaging; POSITRON-EMISSION-TOMOGRAPHY; PROTON RANGE VERIFICATION; IN-VIVO VERIFICATION; PROMPT GAMMA-RAYS; PET MEASUREMENTS; PARTICLE THERAPY; TUMOR-THERAPY; MONTE-CARLO; RADIOTHERAPY; CAMERA;
D O I
10.1016/j.nima.2015.06.056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Ion beam therapy is an emerging modality for high precision radiation treatment of cancer. In comparison to conventional radiation sources (photons, electrons), ion beams feature major dosimetric advantages due to their finite range with a localized dose deposition maximum, the Bragg peak, which can be selectively adjusted in depth. However, due to several sources of treatment uncertainties, full exploitation of these dosimetric advantages in clinical practice would require the possibility to visualize the stopping position of the ions in vivo, ideally in real-time. To this aim, different imaging methods have been proposed and investigated, either pre-clinically or even clinically, based on the detection of prompt or delayed radiation following nuclear interaction of the beam with the irradiated tissue. However, the chosen or ad-hoc developed instrumentation has often relied on technologies originally conceived for different applications, thus compromising on the achievable performances for the sake of cost-effectiveness. This contribution will review major examples of used instrumentation and related performances, identifying the most promising detector developments for next generation devices especially dedicated to on-line monitoring of ion beam treatment. Moreover, it will propose an original combination of different techniques in a hybrid detection scheme, aiming to make the most of complementary imaging methods and open new perspectives of image guidance for improved precision of ion beam therapy. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 50 条
  • [21] Off-line condition monitoring of worn surfaces
    Raadnui, S
    [J]. QRM 2002: PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, AND MAINTENANCE, 2002, : 211 - 214
  • [22] OFF-LINE MONITORING IN ISCHEMIC HEART DISEASE
    MAZZAREL.JA
    BRUCE, RA
    GREEN, E
    [J]. CIRCULATION, 1966, 33 (05) : 719 - &
  • [23] A decision-analyzer for optimal on- and off-line management of adaptive prostate radiotherapy
    Keller, H
    Jaffray, D
    Tome, W
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1854 - 1854
  • [24] Analysis of On- and Off-Line Optimized Predictive Current Controllers for PWM Converter Systems
    Kolar, Johann W.
    Ertl, Hans
    Zach, Franz C.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1991, 6 (03) : 451 - 462
  • [25] STRUCTURAL CHARACTERIZATION OF BACTERIAL LIPOPOLYSACCHARIDES WITH MASS SPECTROMETRY AND ON- AND OFF-LINE SEPARATION TECHNIQUES
    Kilar, Aniko
    Doernyei, Agnes
    Kocsis, Bela
    [J]. MASS SPECTROMETRY REVIEWS, 2013, 32 (02) : 90 - 117
  • [27] Off-line and on-line optical monitoring of microalgal growth
    Lazcano-Hernandez, Hugo-Enrique
    Aguilar, Gabriela
    Antonia Dzul-Cetz, Gabriela
    Patino, Rodrigo
    Arellano-Verdejo, Javier
    [J]. PEERJ, 2019, 7
  • [28] Monitoring adenovirus infections with on-line and off-line methods
    Monica, TJ
    Montgomery, T
    Ayala, JL
    Schoofs, GM
    Whiteley, EM
    Roth, G
    Garbutt, JJ
    Harvey, S
    Castillo, FJ
    [J]. BIOTECHNOLOGY PROGRESS, 2000, 16 (05) : 866 - 871
  • [29] A dedicated software application for treatment verification with off-line PET/CT imaging at the Heidelberg Ion Beam Therapy Center
    Chen, W.
    Bauer, J.
    Kurz, C.
    Tessonnier, T.
    Handrack, J.
    Haberer, T.
    Debus, J.
    Parodi, K.
    [J]. MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [30] ON AND OFF-LINE
    ALEXANDER, M
    [J]. DATAMATION, 1995, 41 (21): : 29 - 29