On- and off-line monitoring of ion beam treatment

被引:48
|
作者
Parodi, Katia [1 ]
机构
[1] Univ Munich, Dept Med Phys, D-85748 Garching, Germany
关键词
Ion beam therapy; Range verification; Positron Emission Tomography; Prompt gamma imaging; POSITRON-EMISSION-TOMOGRAPHY; PROTON RANGE VERIFICATION; IN-VIVO VERIFICATION; PROMPT GAMMA-RAYS; PET MEASUREMENTS; PARTICLE THERAPY; TUMOR-THERAPY; MONTE-CARLO; RADIOTHERAPY; CAMERA;
D O I
10.1016/j.nima.2015.06.056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Ion beam therapy is an emerging modality for high precision radiation treatment of cancer. In comparison to conventional radiation sources (photons, electrons), ion beams feature major dosimetric advantages due to their finite range with a localized dose deposition maximum, the Bragg peak, which can be selectively adjusted in depth. However, due to several sources of treatment uncertainties, full exploitation of these dosimetric advantages in clinical practice would require the possibility to visualize the stopping position of the ions in vivo, ideally in real-time. To this aim, different imaging methods have been proposed and investigated, either pre-clinically or even clinically, based on the detection of prompt or delayed radiation following nuclear interaction of the beam with the irradiated tissue. However, the chosen or ad-hoc developed instrumentation has often relied on technologies originally conceived for different applications, thus compromising on the achievable performances for the sake of cost-effectiveness. This contribution will review major examples of used instrumentation and related performances, identifying the most promising detector developments for next generation devices especially dedicated to on-line monitoring of ion beam treatment. Moreover, it will propose an original combination of different techniques in a hybrid detection scheme, aiming to make the most of complementary imaging methods and open new perspectives of image guidance for improved precision of ion beam therapy. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 50 条
  • [41] OFF-LINE MANAGEMENT
    ALLDERIGE, JM
    [J]. DATAMATION, 1968, 14 (06): : 43 - +
  • [42] On- and off-line evaluation of the single-layer urban canopy model in London summertime conditions
    Tsiringakis, Aristofanis
    Steeneveld, Gert-Jan
    Holtslag, Albert A. M.
    Kotthaus, Simone
    Grimmond, Sue
    [J]. QUARTERLY JOURNAL OF THE ROYAL METEOROLOGICAL SOCIETY, 2019, 145 (721) : 1474 - 1489
  • [43] The Dynamics of Motherhood Performance: Hong Kong's Middle Class Working Mothers On- and Off-Line
    Chan, Annie Hau-nung
    [J]. SOCIOLOGICAL RESEARCH ONLINE, 2009, 13 (04):
  • [44] Off-line emittance measurements of the SPES ion source at LNL
    Montano, J.
    Vasquez, J.
    Andrighetto, A.
    Bassato, G.
    Calabretta, L.
    Poggi, M.
    Prete, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 (01): : 238 - 245
  • [45] Monitoring of the transesterification reaction by continuous off-line density measurements
    Talavera-Prieto, Nieves M. C.
    Ferreira, Abel G. M.
    Moreira, Rui J.
    Portugal, Antonio T. G.
    [J]. FUEL, 2020, 264
  • [46] A microwave driven off-line ion source for ISAC at TRIUMF
    Jayamanna, K
    Cojocaru, G
    Dombsky, M
    Kuo, T
    Laxdal, R
    McDonald, M
    Schmor, PW
    Yuan, D
    Zyuzin, A
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 753 - 755
  • [47] Internet-Initiated Sexual Abuse: Adolescent Victims' Reports About On- and Off-Line Sexual Activities
    Leander, Lina
    Christianson, Sven A.
    Granhag, Paer Anders
    [J]. APPLIED COGNITIVE PSYCHOLOGY, 2008, 22 (09) : 1260 - 1274
  • [48] In-line and off-line NDT defect monitoring for thermoplastic automated tape layup
    Yadav, Neha
    Oswald-Tranta, Beate
    Guerocak, Maximilian
    Galic, Antonio
    Adam, Rene
    Schledjewski, Ralf
    [J]. NDT & E INTERNATIONAL, 2023, 137
  • [49] Power Transformer Health Monitoring: A shift from off-line to on-line detection
    Aburaghiega, Ehnaish
    Farrag, Mohamed Emad
    Hepburn, Donald M.
    Garcia, Belen
    [J]. 2015 50TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2015,
  • [50] On-line and off-line monitoring-diagnosis system(MDS) for power transformers
    Nedelcut, Dorel
    Sacerdotianu, Dumitru
    Tanasescu, Gabriel
    Nicolae, Serban
    Voinescu, Lucian
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 949 - +