Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset

被引:7
|
作者
Valente, Giuseppe [1 ]
Lanting, Brent [1 ]
MacDonald, Steven [1 ]
Teeter, Matthew G. [2 ,3 ]
Van Citters, Douglas [4 ]
Howard, James [1 ]
机构
[1] Western Univ, London Hlth Sci Ctr, Schulich Sch Med & Dent, Div Orthopaed Surg,Dept Surg,Univ Hosp, London, ON, Canada
[2] Western Univ, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
[3] Lawson Hlth Res Inst, Surg Innovat Program, London, ON, Canada
[4] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
关键词
Corrosion; metal-on-polyethylene; taper; total hip arthroplasty; trunnion; trunnionosis; TAPER JUNCTION; CORROSION; METAL; TRUNNIONOSIS; COMPONENTS; INTERFACE;
D O I
10.1177/1120700018814473
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. Methods: A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. Results: There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). Conclusion: There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 50 条
  • [21] Short-stem hip arthroplasty in osteonecrosis of the femoral head
    Thilo Floerkemeier
    Stefan Budde
    Jens Gronewold
    Kerstin Radtke
    Max Ettinger
    Henning Windhagen
    Gabriela von Lewinski
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 715 - 722
  • [22] The Influence of Assembly Force on the Material Loss at the Metallic Head-Neck Junction of Hip Implants Subjected to Cyclic Fretting Wear
    Fallahnezhad, Khosro
    Oskouei, Reza H.
    Badnava, Hojjat
    Taylor, Mark
    METALS, 2019, 9 (04):
  • [23] The wear of the taper junction of the stem trunnion with the femoral head of a total modular hip prosthesis
    Capitanu, Lucian
    Badita, Liliana-Laura
    Tiganesteanu, Constantin
    Florescu, Virgil
    JURNAL TRIBOLOGI, 2019, 23 : 61 - 75
  • [24] Decomposition of micromotion at the head-neck interface in total hip arthroplasty during walking
    Zhang, Guoxian
    Yang, Shu
    Cui, Wen
    Huang, Zhi
    Zhang, Xiaogang
    Zhang, Yali
    Li, Junyan
    Jin, Zhongmin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (05) : 548 - 558
  • [25] Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers
    Bechstedt, Maren
    Gustafson, Jonathan A.
    Mell, Steven P.
    Guehrs, Julian
    Morlock, Michael M.
    Levine, Brett R.
    Lundberg, Hannah J.
    JOURNAL OF BIOMECHANICS, 2020, 103
  • [26] A biomechanical study of the Birmingham mid head resection arthroplasty: Effect of stem size on femoral neck fracture
    Aghayan, Sam
    Shepherd, Duncan E. T.
    Davis, Edward T.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (08) : 913 - 918
  • [27] Mixing of Head-Stem Components in Total Hip Arthroplasty
    Mueller, Ulrike
    Panzram, Benjamin
    Braun, Steffen
    Sonntag, Robert
    Kretzer, J. Philippe
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 945 - 951
  • [28] The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty
    Michael Müller
    Dirk Crucius
    Carsten Perka
    Stephan Tohtz
    International Orthopaedics, 2011, 35 : 981 - 987
  • [29] The association between the sagittal femoral stem alignment and the resulting femoral head centre in total hip arthroplasty
    Mueller, Michael
    Crucius, Dirk
    Perka, Carsten
    Tohtz, Stephan
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (07) : 981 - 987
  • [30] Optimal drilling at femoral head-neck junction for treatment of the femoral head necrosis: Experimental and numerical evaluation
    Tran, Thanh Ngoc
    Baltaci, Yeliz
    Winter, Philipp
    Tschernig, Thomas
    Landgraeber, Stefan
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2023, 248