Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset

被引:7
|
作者
Valente, Giuseppe [1 ]
Lanting, Brent [1 ]
MacDonald, Steven [1 ]
Teeter, Matthew G. [2 ,3 ]
Van Citters, Douglas [4 ]
Howard, James [1 ]
机构
[1] Western Univ, London Hlth Sci Ctr, Schulich Sch Med & Dent, Div Orthopaed Surg,Dept Surg,Univ Hosp, London, ON, Canada
[2] Western Univ, Schulich Sch Med & Dent, Dept Med Biophys, London, ON, Canada
[3] Lawson Hlth Res Inst, Surg Innovat Program, London, ON, Canada
[4] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
关键词
Corrosion; metal-on-polyethylene; taper; total hip arthroplasty; trunnion; trunnionosis; TAPER JUNCTION; CORROSION; METAL; TRUNNIONOSIS; COMPONENTS; INTERFACE;
D O I
10.1177/1120700018814473
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. Methods: A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. Results: There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). Conclusion: There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 50 条
  • [31] Intraoperative evaluation of the effects of femoral component offset and head size on joint stability in total hip arthroplasty
    Jinno, Tetsuya
    Koga, Daisuke
    Asou, Yoshinori
    Morita, Sadao
    Okawa, Atsushi
    Muneta, Takeshi
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01)
  • [32] Osseous Remodeling After Femoral Head-neck Junction Osteochondroplasty
    Nassif, Nader A.
    Pekmezci, Murat
    Pashos, Gail
    Schoenecker, Perry L.
    Clohisy, John C.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 511 - 518
  • [33] Effect of collapse on the deformity of the femoral head–neck junction in osteonecrosis of the femoral head
    Yusuke Kubo
    Goro Motomura
    Satoshi Ikemura
    Kazuhiko Sonoda
    Takuaki Yamamoto
    Yasuharu Nakashima
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 933 - 938
  • [34] Dissociation of modular total hip arthroplasty at the femoral head-neck interface after loosening of the acetabular shell following hip dislocation
    Chu, CM
    Wang, SJ
    Lin, LC
    JOURNAL OF ARTHROPLASTY, 2001, 16 (06): : 806 - 809
  • [35] The influence of head-neck and implant position on the range of motion after total hip arthroplasty
    罗志平
    外科研究与新技术, 2005, (03) : 180 - 180
  • [36] Metal allergy response to femoral head-neck corrosion after total hip replacement
    Meftah, Morteza
    Nicolaou, Nicos
    Rodriguez, Jose A.
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (05): : 530 - 533
  • [37] Head size in primary total hip arthroplasty
    Tsikandylakis, Georgios
    Mohaddes, Maziar
    Cnudde, Peter
    Eskelinen, Antti
    Karrholm, Johan
    Rolfson, Ola
    EFORT OPEN REVIEWS, 2018, 3 (05): : 225 - 231
  • [38] Total hip arthroplasty head-neck contact mechanics: A stochastic investigation of key parameters
    Donaldson, Finn E.
    Coburn, James C.
    Siegel, Karen Lohmann
    JOURNAL OF BIOMECHANICS, 2014, 47 (07) : 1634 - 1641
  • [39] Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses
    Rehmer, Annelie
    Bishop, Nicholas E.
    Morlock, Michael M.
    CLINICAL BIOMECHANICS, 2012, 27 (01) : 77 - 83
  • [40] Anterior and Posterior Femoral Head-Neck Offset Ratio in the Cam Impingement
    Nemtala, Fernando
    Mardones, Rodrigo M.
    Tomic, Alexander
    CARTILAGE, 2010, 1 (03) : 238 - 241