Dissipation Factor and Partial Discharge Measurements for the Quality Assessment of New Coils and Stator Windings of VPI Rotating Machines

被引:0
|
作者
Contin, Alfredo [1 ]
Peruzzi, Gabriele [2 ]
机构
[1] Univ Trieste, DIA, Via A Valerio,10,Bldg C3, I-34127 Trieste, Italy
[2] Marelli Motori, Via Sabbionara 1, I-36071 Arzignano, VI, Italy
关键词
Insulation Systems; Rotating Machines; Dissipation Fader; Partial Discharges; GROUND-WALL INSULATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The correlation between Dissipation Factor (DF) and Partial Discharge (PD) test results in the evaluation of the stator insulation of ac rotating machines, is discussed in this paper. It is well known that DF provides information on the global losses occurring in insulation systems but it does not provide any indication of the distribution of these losses. Above PD Inception Voltage (PDIV), increments of DF values are mainly due to PD in localized defects. Thanks to PD-signal separation and PD sub-pattern analysis, the causes of DF increments can be explained with more accuracy. Moreover, by comparing DF values recorded below the PDIV and PD patterns due to distributed micro-voids, the quality of the impregnation process in terms of void content, can be better evaluated. These results clearly show that the joint use of these two test methods can significantly improve the information on the conditions and the quality of the insulation system.
引用
收藏
页码:455 / 458
页数:4
相关论文
共 42 条
  • [1] A partial discharge coupler for Global VPI (CGVPI) rotating machines
    Kim, YJ
    Kang, DS
    Hwang, DH
    Park, DY
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 19 - 22
  • [2] Reduction Techniques of Partial Discharge, Dissipation Factor, and External Corona for High Voltage Stator Windings
    Emery, F. T.
    [J]. 2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 315 - 327
  • [3] Partial Discharge Measurements on Individual Stator Coils and Bars
    McDermid, W.
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [4] Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windings
    Emery, FT
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 347 - 361
  • [5] On the use of the travelling wave for partial discharge location in rotating machine stator windings
    Zhou, C
    Kemp, IJ
    [J]. 1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 379 - 382
  • [6] LOCALIZATION OF PARTIAL DISCHARGE EVENTS IN HV-WINDINGS OF ROTATING MACHINES
    Oettl, F.
    Engelen, C.
    Staubach, C.
    [J]. 2023 INSUCON - 14TH INTERNATIONAL ELECTRICAL INSULATION CONFERENCE, 2023, : 227 - 231
  • [7] Partial discharge measurements on hydro generator stator windings case studies
    Li, Shunyuan
    Chow, Jennifer M. Y.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2007, 23 (03) : 5 - 15
  • [8] Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines
    Farahani, M
    Borsi, H
    Gockenbach, E
    [J]. 2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 454 - 457
  • [9] On line monitoring of partial discharges on stator windings of large rotating machines in the petrochemical environment
    Bethge, A
    Lo, PK
    Phillipson, JT
    Weidner, JR
    [J]. INDUSTRY APPLICATIONS SOCIETY 44TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 1997, : 267 - 273
  • [10] New VPI Insulation System of High Voltage Stator Windings of Large Rotating Electrical Machines Based on Cogemica VPI Tapes and One-component Epoxy Impregnation Varnish
    Bezdek, Zdenek
    [J]. 2020 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING, DIAGNOSTIKA, 2020, : 180 - 184