Partial Discharge Measurements on Individual Stator Coils and Bars

被引:0
|
作者
McDermid, W. [1 ]
机构
[1] Manitoba Hydro, Winnipeg, MB, Canada
关键词
electric machines; stator coils/bars; partial discharge;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In 2014 the second edition of IEEE Std 1434 Guide for the Measurement of Partial Discharges in AC Electric Machinery was approved. This guide includes possible on-line and off-line PD measurements on complete stator windings as well as on individual stator coils and bars. It was agreed that further work would be initiated with the objective of developing a recommended practice for PD measurements on coils and bars that might ultimately result in the establishment of pass/fail criteria. This paper reviews some of the alternative methods that are being considered.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Update on Partial Discharge Screening Tests for Stator Bars & Coils
    McDermid, W.
    Bromley, J. C.
    Black, T.
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 20 - 22
  • [2] Comparative Study of Phase Resolved Partial Discharge Patterns obtained with Different Instruments on Individual Stator Bars and Coils
    Levesque, Melanie
    Seol, Yoon Duk
    Hudon, Claude
    Provencher, Helene
    [J]. 2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 249 - 252
  • [3] Status of IEEE P2465-Draft Recommended Practice for Pulse-type Partial Discharge Measurements on Individual Stator Bars and Coils
    McDermid, W.
    Partyka, M.
    Black, T.
    [J]. 2020 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2020, : 253 - 256
  • [4] Partial discharge screening test for internal voids and delaminations in stator coils and bars
    McDermid, W
    Bromley, JC
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (03) : 292 - 297
  • [5] Scanning Individual Stator Bars and Coils with an Antenna to Detect Localized Partial Discharges
    Hudon, Claude
    Levesque, Melanie
    Bernier, Simon
    Provencher, Helene
    Cloutier-Rioux, Emilie
    Seol, Yoon Duk
    [J]. 2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 457 - 460
  • [6] Working Towards a Recommended Practice for PD Measurements on Individual Stator Coils and Bars 2015-2016
    McDermid, W.
    [J]. 2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 352 - 355
  • [7] RELATIONSHIP BETWEEN PARTIAL DISCHARGE PULSE-HEIGHT ANALYSIS AND SUBSEQUENT VOLTAGE ENDURANCE OF STATOR BARS AND COILS
    MCDERMID, W
    BROMLEY, JC
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (04) : 721 - 731
  • [8] Comparative measurements of two partial discharge measurements used for form wound coils/bars as quality assurance tests
    Cherukupalli, S
    Halldorson, GL
    Tan, C
    [J]. ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 541 - 546
  • [9] Insulation resistance measurements versus temperature made on aged stator bars and coils
    Zhu, H.
    [J]. 2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, : 215 - 218
  • [10] UHF Measurement of Partial Discharge on Stator Bars Using Patch Antennas
    Partyka, Mike
    Bridges, Greg E.
    McDermid, Bill
    Black, Tyler
    Kordi, Behzad
    [J]. 2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 453 - 456